Circuit breaker, S0, motor protection, Class 10, A-release 0.35-0.5A, N-release 6.5A - 3RV20210FA10
€ 60,10 exkl. USt.
Circuit breaker, S0, motor protection, Class 10, A-release 0.35-0.5A, N-release 6.5A - 3RV20210FA10 is backordered and will ship as soon as it is back in stock.
Circuit breaker Size S0 for motor protection, CLASS 10 A-release 0.35...0.5 A N-release 6.5 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 for motor protection for safe shutdown in the event of a short circuit and protection of consumers and systems against overload, as well as for safe disconnection of the system from the mains. The compact and climate-resistant circuit breakers are optimized for use in consumer feeders due to their low heat dissipation, of course also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-loaded terminals for a fast, maintenance-free and vibration-proof connection, and optionally with an integrated auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary trip units, signaling switches etc., are uniform for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces the main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 60,10 exkl. USt.
Circuit breaker, S0, motor protection, Class 10, A-release 0.35-0.5A, N-release 6.5A - 3RV20210FA10 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Rated operational voltage | 690..690 V | With integrated auxiliary switch | No |
| Phase failure sensitive | Yes | Width | 45 mm |
| Number of poles | 3 | Power loss | 5.5 W |
| Type of electrical connection for main current circuit | Screw connection | Type of control element | Other |
| Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA | Depth | 97 mm |
| Device construction | Built-in device fixed-mounted technology | Height | 97 mm |
| Overload release current setting | 0.35..0.5 A | Rated operational power at AC-3, 400 V | 0.1 kW |
| Rated permanent current Iu | 0.5 A | With integrated undervoltage release | No |
| Setting range of the instantaneous short-circuit release | 6.5..6.5 A | Release system | Magnetic |
| Rated operational power at AC-3, 230 V | 0.1 kW | Degree of protection (IP) | IP20 |
| With thermal overload protection | Yes |