Reversing starter Failsafe, 3RM1, 500V, 0.09 - 0.75kW, 0.4 - 2A, DC 24 V, spring-type terminal (Push-In) Reversing starter Failsafe SIRIUS 3RM1 for operational switching of three-phase motors. Narrow design, multifunctional, with electronic overload protection, long-lasting and energy-efficient hybrid switching technology, low device variance due to wide setting range, easy installation due to reduced wiring effort, quick fault diagnosis thanks to LED display, innovative housing concept e.g. with labeled covers and removable terminals. Available as direct or reversing starter, optionally with ATEX certification and safety-related shutdown, with different motor current ranges, supply voltage types and connection technologies. Extensive accessories such as device connectors, fuse modules, infeed systems or sealable covers complete the system. Get started in the tightest spaces - SIRIUS 3RM1 motor starters.
€ 221,20 exkl. USt.
Reversing Starter Failsafe, 0.4-2 A, DC 24 V, Spring-type terminal – 3RM13022AA04 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Rated power, 460 V, 60 Hz, 3-phase | 0.551624 kW | Rated operational current Ie | 2 A |
| Number of auxiliary contacts as normally open contact | 1 | Release class | CLASS 10 A |
| Type of motor starter | other | Rated operational power at AC-3, 230 V, 3-phase | 0.37 kW |
| With transformer | No | Supports protocol for ASI | No |
| Supports protocol for DeviceNet | No | Number of auxiliary contacts as normally closed contact | 1 |
| Type of electrical connection for auxiliary and control current circuit | Spring-type terminal | Suitable for DIN rail mounting | Yes |
| Supports protocol for PROFIBUS | No | Supports protocol for PROFINET CBA | No |
| External reset possible | No | Overload release current setting | 2..2 A |
| Number of control points | 0 | Supports protocol for MODBUS | No |
| Supports protocol for Data-Highway | No | Supports protocol for DeviceNet Safety | No |
| Supports protocol for PROFIsafe | No | Height | 100 mm |
| With short-circuit release | No | Ambient temperature, upper limit without restrictions | 60 °C |
| Supports protocol for SERCOS | No | Rated operational current at AC-3, 400 V | 2 A |
| Supports protocol for PROFINET IO | No | Supports protocol for SafetyBUS p | No |
| Type of voltage for actuation | DC | Temperature-compensated overload protection | No |
| Number of indicator lights | 4 | With fuse | No |
| Rated operational power at AC-3, 400 V | 0.75 kW | Connection type main current circuit | Spring-type terminal |
| Degree of protection (IP) | IP20 | Supports protocol for TCP/IP | No |
| Supports protocol for INTERBUS | No | Supports protocol for AS-Interface Safety at Work | No |
| Depth | 141.6 mm | Supports protocol for CAN | No |
| Supports protocol for SUCONET | No | Supports protocol for LON | No |
| Supports protocol for EtherNet/IP | No | Width | 22.5 mm |
| Rated control supply voltage DC | 24..24 V | Suitable for EMERGENCY STOP | No |
| Supports protocol for Foundation Fieldbus | No | Supports protocol for INTERBUS-Safety | No |
| Supports protocol for other bus systems | No |