Data cable Cat.7 Duplex S/FTP 2x(4x2xAWG23/1) LSHF Eca 500m drum 500 m
€ 640,07 exkl. USt.
Data cable Cat.7 Duplex S/FTP 2x(4x2xAWG23/1) LSHF Eca 500m drum 500 m is backordered and will ship as soon as it is back in stock.
10 GBit installation cable, duplex, pair-shielded installation cable Cat.7 AWG 23 S/FTP, 2 x 4 pairs (PiMF), pair shield: plastic composite film, aluminum coated, overall shield: tinned copper braid, cable outer diameter 7.2/15.0 mm, cable jacket color: blue, coupling attenuation 80 dB, applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-4-1 and IEC 61156-5, cable jacket LSHF (LSOH), flame retardancy: IEC 60332-1, IEC 60754-2 and IEC 61034, fire behavior: Class E, approx. (classification according to EN 13501-6) Delivery unit: on drum - 500 m
€ 640,07 exkl. USt.
Data cable Cat.7 Duplex S/FTP 2x(4x2xAWG23/1) LSHF Eca 500m drum 500 m is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Duplex | Yes | Number of stranded elements | 8 |
| Protective jacket | without | Fire behaviour according to EN 13501-6: Class | Eca |
| Fire behaviour according to EN 13501-6: Smoke development | without | Jacket material | other |
| Cable geometry | round | Shield over stranding | braid |
| Cable longitudinally watertight | No | Low smoke according to EN IEC 61034-2 | No |
| Outer diameter approx. | 7.2 mm | Conductor surface | bare |
| Suitable for direct burial | No | Specification of jacket material | other |
| Number of cores | 16 | Shield over stranding element | Foil |
| Weight | 109.2 kg/km | Conductor class | Class 1 = solid |
| Cable transversely watertight | No | Armouring/reinforcement | without |
| Permissible external cable temperature during installation/handling | 0..50 °C | Conductor material | Copper |
| Fire behaviour according to EN 13501-6: Droplet behaviour | without | Cable type | S/FTP |
| Conductor diameter | 0.56 mm | Core identification | Colour |
| Stranding | other | Oil-resistant according to EN IEC 60811-404 | No |
| AWG size | 23 | Fire behaviour according to EN 13501-6: Acid development | without |
| Permissible external cable temperature after installation without vibration | -20..60 °C | Specification of core insulation | Polyethylene (PE) |
| Halogen-free according to EN IEC 60754-2 | Yes | Category | 7 |
| NVP value | 79 % | Stranding element | Pairs |
| Core insulation material | other | Jacket colour | blue |
| Min. permissible bending radius, flexible use/free movement | 80 mm | Min. permissible bending radius, stationary use/fixed installation | 40 mm |