• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

VAILLANT  Art.Nr: 15473004085579

VAILLANT Vaillant Air/Water Heat Pump 12 kW aroTHERM plus VWL 125/8.1 Monobloc R290 – 8000033713 DACH Version

Regular price
Regular price € 11.691,47 inkl. USt.
€ 9.742,89 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
DACH VersionGermany · Austria · SwitzerlandControl and documentation in German, mains connection 400 V / 50 Hz according to Central European standard – usable in all three countries.
12.14 kW
Heating output at A−7/W35
202 %
Efficiency ηs at 35 °C
R290
Natural refrigerant
75 °C
Max. flow temperature

Advantages at a glance

A+++ at 35 °C and at 55 °C

202 % space heating efficiency at 35 °C, 151 % at 55 °C – the highest rating in both temperature classes.

🌱

Refrigerant R290

Propane with a GWP of 0.02 – practically no global warming potential and long-term regulatory security.

🔊

Sound Safe System

59.9 dB(A) sound power maximum, only 27.5 dB(A) at 3m distance in night mode.

🌡️

Flow up to 75 °C

Renovation without radiator replacement: even existing radiator systems can continue to operate efficiently.

❄️

Active cooling

Activatable cooling operation with 11.66 kW at A35/W18 and EER 5.03. On-site preparation of the heating system required.

🏠

Largest model in the series

12.14 kW at -7 °C covers even large or poorly insulated buildings, without resorting to a second heat generator.

Performance & Efficiency according to EN 14511

Operating point Heating capacity / Input / COP
A7/W35 5.74 kW / 1.07 kW / 5.39
A2/W35 5.82 kW / 1.32 kW / 4.40
A−7/W35 12.14 kW / 4.46 kW / 2.72
A7/W45 6.03 kW / 1.53 kW / 3.94
A7/W55 5.62 kW / 1.80 kW / 3.12
A−7/W55 11.99 kW / 6.06 kW / 1.98
Cooling A35/W18 11.66 kW / 2.32 kW / EER 5.03

Technical data

Parameter Value
Energy efficiency class 35 °C / 55 °C A+++ / A+++
Space heating efficiency ηs 35 °C / 55 °C 202 % / 151 %
Heating capacity partial load point A (Tj −7 °C) W35 10.1 kW
Refrigerant / Filling quantity / GWP R290 / 1.3 kg / 0.02
Electrical power consumption (max) 8.0 kW
Power supply / Current (max) 400 V (50 Hz) / 14 A
Protection class / Safety class IPX4 / I
Sound power level (max) 59.9 dB(A)
Sound power A7/W35 in silent mode 49.6 dB(A)
Dimensions (H × W × D) 1,480 × 1,100 × 450 mm
Weight 206 kg
Heating flow and return connection G 1¼″
Heating circuit content 4.5 l

Application limits

Parameter Value
Flow temperature heating 20 – 75 °C
Distance outdoor unit to last indoor unit max. 20 m
Operating pressure heating circuit max. 2.5 bar
Installation Monoblock, outdoor installation
Color black-grey RAL 7021

Scope of delivery

aroTHERM plus outdoor unit Condensate drain funnel Bag of small parts VR 940 communication module Documentation

Frequently asked questions

What does the DACH version mean?

The unit, control, and documents are designed for the German-speaking region: menu navigation and documentation in German, mains connection 400 V / 50 Hz. This allows the heat pump to be used equally in Germany, Austria, and Switzerland. Subsidies and registration requirements differ by country – your local installer will clarify this.

Why R290 and not R32 or R410A?

R290 is propane, a natural refrigerant with a global warming potential of 0.02 instead of several hundred. It is not subject to the scarcity of fluorinated refrigerants and at the same time achieves higher flow temperatures – here up to 75 °C.

Does the 12 kW size fit my house?

The VWL 125/8.1 delivers 12.14 kW at -7 °C outside temperature and 35 °C flow. It is the largest stage in the series and is suitable for large residential buildings, two-family houses, or existing buildings with 11 to 14 kW heating load. The exact dimensioning requires a heating load calculation according to EN 12831.

How does it differ from the 105/8.1?

Housing, refrigerant quantity, efficiency values, and sound behavior are almost identical. The difference lies in the heating output at low outside temperatures: 12.14 kW instead of 10.58 kW at -7 °C.

How loud is the heat pump in operation?

59.9 dB(A) sound power at maximum, in silent mode at A7/W35 only 49.6 dB(A). In night mode, it is 27.5 dB(A) at 3 m distance – quieter than a quiet living room.

What do I need in addition to the outdoor unit?

The aroTHERM plus is a monoblock, the complete refrigeration circuit is outside. For a complete system, depending on the concept, a hydraulic station or a uniTOWER, a hot water tank, and the system control are added. We can put together the right package on request.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on dimensioning. Shipping within Austria is free for orders over €5,000.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download
Vorschau Scrollen im PDF möglich · Vollbild über das Öffnen-Symbol