• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

VAILLANT  Art.Nr: 15472162341195

VAILLANT Vaillant A/W, B/W, W/W Heat Pump 8 kW flexoTHERM VWF 87/4 Indoor Installation – 0010016421 DACH Version

Regular price
Regular price € 10.596,57 inkl. USt.
€ 8.830,48 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
DACH VersionGermany · Austria · SwitzerlandControl and documentation in German, mains connection 400 V / 50 Hz according to Central European standard – usable in all three countries.
8.82 kW
Heating output at B0/W35
4.84 COP
Coefficient of performance at B0/W35
3 sources
Brine, water or air
65 °C
Flow temperature without auxiliary heating
Please note: The controller must be ordered separately. Also, connection fittings and the flow sensors VR 10 according to the hydraulic diagram. For air operation, the aroCOLLECT air collector is also required. We can put together a suitable package on request.

Advantages at a glance

🔄

One machine, three heat sources

Brine, groundwater or outside air – the flexoTHERM works with all three. The source can be determined after the drilling permit, not before.

⚡

A+++ at 35 °C

202 % space heating efficiency in brine mode, 8.82 kW at B0/W35 with a COP of 4.84. In water mode, it's 5.17 at W10/W35.

🌡️

65 °C flow temperature through EVI

The intermediate injection keeps the flow temperature high even at low source temperatures. With auxiliary heating, up to 75 °C are possible.

🔊

Sound Safe System

42.4 dB(A) sound power at B0/W35 – quiet enough for the technical room in a residential building.

📈

Integrated meter ex works

Heat quantity meter and electricity meter are installed as standard. The seasonal performance factor can thus be verified without additional technology.

📜

10 years on the compressor

Vaillant offers a 10-year material guarantee on the scroll compressor. Details are regulated by the warranty conditions.

Performance & Efficiency according to EN 14511

Operating point Output / Input / COP or EER
Brine B0/W35 8.82 kW / 1.82 kW / 4.84
Brine B0/W55 8.94 kW / 2.78 kW / 3.22
Water W10/W35 9.94 kW / 1.92 kW / 5.17
Water W10/W55 10.28 kW / 2.96 kW / 3.47
Air A7/W35 8.74 kW / 1.91 kW / 4.58
Air A2/W35 7.79 kW / 1.99 kW / 3.91
Air A−7/W35 6.45 kW / 2.01 kW / 3.21
Air A7/W55 9.45 kW / 2.95 kW / 3.21
Cooling A35/W18 8.52 kW / 2.73 kW / EER 3.12

Technical data

Parameter Value
Energy efficiency class 35 °C / 55 °C A+++ / A++
Space heating efficiency ηs 35 °C (brine / air) 202 % / 165 %
Space heating efficiency ηs 55 °C 147 %
Heating output partial load point A (Tj −7 °C) W35 8.8 kW
Refrigerant / charge / GWP R410A / 2.4 kg / 2.088
Electric auxiliary heating 9.0 kW, multi-stage
Power consumption including auxiliary heating (max) 12.8 kW
Power supply compressor / controller 400 V / 230 V (50 Hz)
Fusing 3 × 25 A slow-blow
Sound power level B0/W35 / A7/W35 / W10/W35 42.4 / 45.8 / 47.9 dB(A)
Heating and heat source connection G 1½″
Dimensions (H × W × D) 1,183 × 595 × 600 mm
Weight net / ready for operation 160 kg / 167 kg
Content heating water / heat transfer fluid 3.9 l / 3.1 l

Operating limits

Parameter Value
Flow temperature heating mode 25 – 65 °C
Flow temperature with auxiliary heating 25 – 75 °C
Operating pressure heating circuit and heat source max. 3 bar
Starting current with limiter 19.0 A
Minimum volume of installation room according to EN 378 5.45 m³
Installation Indoor installation

Scope of delivery

flexoTHERM exclusive with casing Brine circuit safety valve ½″, 3 bar Internet module Instructions and warranty card

Frequently asked questions

What does the DACH version mean?

The device, control system and documentation are designed for the German-speaking area: menu navigation and documentation in German, mains connection 400 V / 50 Hz. This means the heat pump can be used equally in Germany, Austria and Switzerland. Subsidies and registration requirements differ by country – your local installer will clarify this.

What do L/W, S/W and W/W mean?

The flexoTHERM works with three heat sources: air (via the aroCOLLECT air collector), brine (ground collector or deep bore) and groundwater. The device itself remains the same – only the source changes. Practical if it is not yet certain at the time of purchase whether the drilling permit will be granted.

Which source is the most efficient?

Groundwater: 5.17 COP at W10/W35. Brine follows with 4.84 at B0/W35, air with 4.58 at A7/W35. The difference becomes greater at low outside temperatures – soil and groundwater remain constant, air does not.

Why R410A and not R290?

The flexoTHERM comes from an older series and works with R410A (GWP 2.088, 2.4 kg filling quantity). For this, it offers the source flexibility that is not available with the new R290 monoblocks. If you prioritize a natural refrigerant, the aroTHERM plus is a better choice.

Can it also cool?

Yes, actively with 8.52 kW at A35/W18. In brine mode, passive cooling via the ground is also possible – this only costs electricity for the circulation pumps.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on design. For orders over €5,000, shipping within Austria is free.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download
Vorschau Scrollen im PDF möglich · Vollbild über das Öffnen-Symbol

Technische Parameter

Produkteigenschaften ETIM

Ursprungsland
AT
Zolltarifnummer
85161080
eClass
36140700
eClass Bezeichnung
Wärmepumpe
ETIM-Klasse
Wärmepumpe (Wasser/Wasser)
Geeignet für offene Quelle (Grundwasser)
Ja
Geeignet für geschlossene Kreislauf Quelle (Bodenkollektor)
Ja
Heizleistung bei 0/35 °C (B0/W35) nach EN 14511
7.8 - 7.8 kW
COP bei 0/35 °C (B0/W35) nach EN 14511
4
Geeignet für warmes Trinkwasser
Ja
Vorrichtung für warmes Trinkwasser integriert
Ja
Geeignet für Kühlen
Ja
Kühlleistung
8.6 - 8.6 kW
Kühlung integriert
Ja
Typ Kältemittel
R410a
Füllmenge Kältemittel
2.4 kg
Global warming potential (GWP)
2088
Anschlussspannung
400 V
Breite
595 mm
Höhe
1183 mm
Tiefe
1200 mm
Gewicht
160 kg
Schallleistungspegel nach EN 12102 bei 0/35 °C
42 dB(A)
Schutzart (IP)
IP25