ELTAKO Staircase Light Timer 230V+UC. 1 N/O contact not floating 10A/250VAC – 61100301
€ 44,16 exkl. USt.
ELTAKO Staircase Light Timer 230V+UC. 1 N/O contact not floating 10A/250VAC – 61100301 is backordered and will ship as soon as it is back in stock.
1 NO contact, not isolated, 10A/250V AC, 230V LED lamps up to 600W, CFL up to 200W, incandescent lamps up to 2000W. Switch-off warning and push-button continuous light can be switched on. Stand-by loss only 0.7 watts. With CFL optimization. For flush-mounting. 45mm long, 45mm wide, 18mm deep. Zero-crossing switching to protect contacts and lamps. Due to the use of a bistable relay, there is no coil power loss or resulting heat generation when switched on. After installation, wait for the automatic brief synchronization before connecting the switched load to the mains. Control, supply, and switching voltage 230V. Additionally with galvanically isolated universal control voltage 8..230V UC. Time setting 1 to 12 minutes. Glim lamp current up to 50mA, depending on the ignition voltage of the glim lamps. For 3- and 4-wire circuits, re-switchable, with attic lighting in 4-wire circuits. Automatic detection of the circuit type. After a power failure, the lighting is switched on again if the timer has not yet expired. If the switch-off warning is activated, the lighting flickers for approx. 30 seconds before the time expires and a total of 3 times at shortening intervals. If the push-button continuous light is activated, it can be set to continuous light by pressing the button for longer than 1 second, which is automatically switched off after 60 minutes or can be switched off by pressing the button for longer than 2 seconds. If both push-button continuous light and switch-off warning are activated, the switch-off warning occurs only after the continuous light has been switched off. If CFLs are switched completely or partially, set the switch-off warning with push-button continuous light CFL on the lower rotary switch. Within the first second after switching on or re-switching, the time can be extended in the TLZ functions by pressing the button briefly up to 3 times (pumping). Each press adds the set time once. Switchable to the ESV function, impulse switch with fall-back delay up to 120 minutes. In this function, it switches off automatically after the adjustable delay time has expired if the manual off command has not been given. If the delay time is set to minimum in the ESV function, the fall-back delay is switched off and the normal impulse switch function ES results.
€ 44,16 exkl. USt.
ELTAKO Staircase Light Timer 230V+UC. 1 N/O contact not floating 10A/250VAC – 61100301 is backordered and will ship as soon as it is back in stock.