• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

ELTAKO  Art.Nr: 15473186603339

ELTAKO Multifunction Time Relay, 18 functions, 1 potential-free changeover contact 10A/250V AC – 23001005

Regular price
Regular price € 58,81 inkl. USt.
€ 49,01 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

1 potential-free NO contact 10A/250V AC, 230V LED lamps up to 200W, incandescent lamps 2000W*. Stand-by loss only 0.02-0.6 watts. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 1 division unit = 18mm wide, 58mm deep. With the patented ELTAKO Duplex Technology (DX), the normally potential-free contacts can switch at zero crossing when switching 230V AC 50Hz, thereby drastically reducing wear. To do this, simply connect the neutral conductor to terminal (N) and L to 15(L). This results in an additional stand-by loss of only 0.1 watts. Universal control voltage 12..230V UC. Supply voltage same as control voltage. Times between 0.1 seconds and 40 hours are adjustable. Due to the use of a bistable relay, there is no coil power loss or heating in the switched-on state. After installation, wait for the automatic short synchronization before connecting the switched load to the mains. Depending on the connection of the power supply to terminals B1-A2 or B2-A2, two different function levels can be selected. Functions F when connecting the power supply to B1-A2: (Stand-by loss 0.02-0.4W) RV = release delay. AV = ON delay. TI = clock generator starting with pulse. TP = clock generator starting with pause. IA = pulse-controlled ON delay (e.g. automatic door opener). EW = ON wipe. AW = OFF wipe. ARV = ON and OFF delay. ON = continuous ON. OFF = continuous OFF. Functions (F) when connecting the power supply to B2-A2 (Stand-by loss 0.02-0.6W): SRV = impulse switch with release delay. ER = relay. EAW = ON and OFF wipe. ES = impulse switch. IF = pulse former. ARV+ = additive ON and OFF delay. ESV = impulse switch with release delay and OFF pre-warning. AV+ = additive ON delay. ON = continuous ON. OFF = continuous OFF. The LED below the large rotary switch indicates the contact position during the time sequence. It flashes as long as the NO contact 15-18 is open (15-16 closed) and lights continuously as long as the NO contact 15-18 is closed (15-16 open). The time base T is set with the middle detented rotary switch T. The basic values available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours, and 4 hours. The total time results from the time base multiplied by the multiplier. The multiplier xT is set with the upper detented rotary switch xT and is between 1 and 10. This allows times between 0.1 seconds (time base 0.1 seconds and multiplier 1) and 40 hours (time base 4 hours and multiplier 10) to be set. * The maximum load can be used from a delay or clock time of 5 minutes. For shorter times, the maximum load is reduced as follows: Up to 2 seconds to 15%, up to 2 minutes to 30%, up to 5 minutes to 60%.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Produkteigenschaften ETIM

Ursprungsland
CN
Zolltarifnummer
85364900
eClass
27144000
eClass Bezeichnung
Installationsschalterprogramm
Serien
Zeitrelais
ETIM-Klasse
Zeitrelais Installationstechnik für Reiheneinbau
Ausführung des elektrischen Anschlusses
Schraubanschluss
Zeitbereich
0.1 - 14400 s
Bemessungssteuerspeisespannung AC 50 Hz
230 - 230 V
Bemessungssteuerspeisespannung DC
12 - 12 V
Anzahl der Ausgänge, unverzögert, Schließer
1
Geeignet für Frontmontage
Nein
Werkstoff des Kontakteinsatzes
Thermoplast
Werkstoff des Kontaktes
Kupfer
Werkstoff der Kontaktbeschichtung
sonstige
Betriebsspannung AC 50 Hz
230 - 230 V
Betriebsspannung DC
8 - 8 V
Spannungsart der Betriebsspannung
AC
Nennstrom
10 A
Max. Einschaltstrom
10 A
Breite
18 mm
Höhe
66 mm
Tiefe
58 mm