ELTAKO Analog adjustable multifunction time relay as UC. 1 N/O contact potential-free 10A/25 – 61100604

Regular price
Regular price € 53,38 inkl. USt.
€ 44,48 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Power MOSFET with almost unlimited number of switching operations up to 400W. Automatic lamp detection. Stand-by loss only 0.3 Watt. Dimming to minimum and maximum brightness as well as soft on/soft off when switching lamps can also be set. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 1 module = 18mm wide, 58mm deep. Digitally adjustable and fully electronic multifunctional time relay for lamps up to 400W depending on ventilation conditions. Dimmable 230V LED lamps and dimmable energy-saving lamps also depending on the lamp electronics and the dimming type. If the minimum brightness is not set to 0, it will not switch off, but dim down to the set percentage. Up to 3600W with power additives LUD12-230V at terminals X1 and X2. Universal control voltage locally 12..230V UC and additionally universal voltage control inputs 8..230V UC central on and central off. The control inputs are galvanically isolated from the supply and switching voltage 230V. Switching at zero crossing to protect the lamp. From 110V control voltage glow lamp current 5mA. Automatic electronic overload protection and overtemperature shutdown. Both the function and the times are entered with the two buttons MODE and SET and digitally displayed on an LC display. When setting the time, all values can be entered within the preselected time frames (0.1 to 9.9 or 1 to 99 seconds, minutes or hours). The longest time is 99 hours. This allows 600 time settings. The entered time(s) is (are) continuously displayed digitally. Adjustable functions: RV = switch-off delay, AV = switch-on delay, AV+ = additive switch-on delay, TI = clock generator starting with pulse, TP = clock generator starting with pause, IA = pulse-controlled switch-on delay, IF = pulse shaper, EW = switch-on wiper, AW = switch-off wiper, EAW = switch-on and switch-off wiper, ARV = switch-on and switch-off delay, ARV+ = additive switch-on and switch-off delay, ES = impulse switch, SRV = impulse switch with switch-off delay, ESV = impulse switch with switch-off delay and switch-off pre-warning, ER = relay, ON = continuous ON, OFF = continuous OFF. For functions TI, TP, IA, EAW, ARV and ARV+, a different second time can be entered, also with a different time frame. Setting times and functions: By pressing the MODE button, the LCD element to be changed is selected. The currently accessed element flashes. By pressing the SET button, the accessed element is changed. This can be about the function, the time frame, time T1 or time T2 (only for TI, TP, IA, EAW, ARV and ARV+). Each input is finished with the MODE button. After setting the time with MODE, no element flashes anymore – the time relay is ready for operation. With the next press of the MODE button, the input cycle starts again, all set parameters are retained if they are not changed with SET. 25 seconds after the last operation and with the element still flashing, the input cycle is automatically terminated and the previous changes are forfeited. Setting of additional parameters valid for all functions: If the MODE button is pressed for longer than 2 seconds, you enter the submenu. The parameter to be changed is selected with the SET button and confirmed with MODE. The value is entered with the SET button and confirmed with MODE. After the submenu item LED, you automatically return to the main menu. MIN = minimum brightness in the off state adjustable to 0 and from 10 to 89 (%), factory setting = 0. MAX = maximum brightness in the on state adjustable from 10 to 99 (%), factory setting = 99. MAX must be at least 10 steps above MIN. RMP = switch-on and switch-off ramp (soft on and soft off) adjustable from 0 = 10ms to 99 = 1s, factory setting = 0. LED = LED+ for dimmable 230V LED lamps, which due to their design cannot be dimmed down far enough in automatic mode (trailing edge) and therefore have to be forced to leading edge, is activated via the MODE button, factory setting = LED without +. Display functions of the LC display: If the functions ON or OFF have been selected, no time is displayed, but an arrow pointing to ON or OFF. For all other functions, the set time(s), the function abbreviation and an arrow next to ON or OFF are displayed as a switching position indicator. During the time sequence, the running time flashes and the remaining time is displayed. Power failure safety: The set parameters are stored in an EEPROM and are therefore immediately available again after a power failure.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Produkteigenschaften ETIM

Ursprungsland
CN
Zolltarifnummer
85364900
eClass
27144000
eClass Bezeichnung
Installationsschalterprogramm
Serien
Zeitrelais
ETIM-Klasse
Zeitrelais Installationstechnik für Reiheneinbau
Ausführung des elektrischen Anschlusses
Schraubanschluss
Zeitbereich
0.1 - 14400 s
Bemessungssteuerspeisespannung AC 50 Hz
230 - 230 V
Bemessungssteuerspeisespannung DC
12 - 12 V
Anzahl der Ausgänge, unverzögert, Schließer
1
Werkstoff des Kontakteinsatzes
Thermoplast
Werkstoff des Kontaktes
Kupfer
Werkstoff der Kontaktbeschichtung
sonstige
Betriebsspannung AC 50 Hz
230 - 230 V
Betriebsspannung DC
8 - 8 V
Spannungsart der Betriebsspannung
AC
Nennstrom
10 A
Max. Einschaltstrom
10 A
Breite
18 mm
Höhe
66 mm
Tiefe
58 mm