Circuit breaker, S00, for motor protection, Class 10, A-release 1.1-1.6A, N-release 21A - INN 3RV20111AA10
€ 65,11 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 1.1-1.6A, N-release 21A - INN 3RV20111AA10 is backordered and will ship as soon as it is back in stock.
Circuit breaker size S00 for motor protection, CLASS 10 A release 1.1...1.6 A N release 21 A screw terminal standard switching capacity Circuit breaker SIRIUS 3RV2 for motor protection for safe shutdown in the event of a short circuit and protection of loads and the plant against overload, as well as for safe disconnection of the plant from the mains. The compact and climate-resistant circuit breakers are optimized for use in load feeders due to their low heat dissipation, and of course also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device variants are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-type terminals for a fast, maintenance-free and vibration-proof connection, and optionally with an integrated auxiliary contact. The comprehensive accessories, such as auxiliary contacts, auxiliary releases, signaling switches, etc., are uniform for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 65,11 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 1.1-1.6A, N-release 21A - INN 3RV20111AA10 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Rated operational power at AC-3, 230 V | 0.3 kW | Rated operational voltage | 690..690 V |
| Rated permanent current Iu | 1.6 A | Trip technique | magnetic |
| Rated operational power at AC-3, 400 V | 0.55 kW | With thermal overload protection | Yes |
| Phase-failure sensitive | Yes | Setting range of the undelayed short-circuit release | 21..21 A |
| Overload release current setting | 1.1..1.6 A | Device construction type | Built-in device fixed-mount technique |
| Depth | 97 mm | Height | 97 mm |
| Type of control element | Rotary knob | Connection type main current circuit | Screw connection |
| Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA | With integrated auxiliary switch | No |
| Number of poles | 3 | With integrated undervoltage release | No |
| Width | 45 mm | Degree of protection (IP) | IP20 |