SINAMICS Power Module PM240-2 with integrated Class A filter with integrated brake chopper 3AC380-480V+10/-10% 47-63Hz power high overload: 0.37kW at 200% 3s, 150% 57s, 100% 240s, ambient temperature -10 to +50°C, power low overload: 0.55kW at 150% 3s, 110% 57s, 100% 240s, ambient temperature -10 to +40°C 196x 73x 165 (HxWxD), FSA IP20 degree of protection without Control Unit and Basic Operator Panel approved from CU firmware version V4.6 Power Module SINAMICS Power Module PM240-2, the ideal Power Module for standard applications in mechanical engineering for the SINAMICS G120 modular frequency converter. As part of the SINAMICS G120 modular frequency converter (consisting of power unit, control unit, operator panel), the PM240-2 Power Modules (IP20 degree of protection) have a brake chopper (four-quadrant applications) and are suitable for a wide range of applications in general mechanical engineering. The PM240-2 power unit can be flexibly combined with various control units depending on the application scope and safety requirements (e.g. STO, SS1, SBC, SLS, SDI, SSM). In combination with the CU230-2, CU240x-2 and CU250S-2 control units, the functional SINAMICS G120 frequency converter is created. The PM240-2 with IP20 degree of protection is a built-in unit for the control cabinet in a power range from 0.55 kW to 250 kW, as well as the three voltage variants 200 V, 400 V and 690 V. The Power Modules are available unfiltered or with an integrated Class A line filter and in the seven frame sizes from FSA to FSG. For optimal dissipation of waste heat outside the control cabinet, the power unit is also available as a push-through version. The frame sizes also offer Safety Integrated. Due to the robust design, cable lengths of up to 450 meters (frame size FSF/FSG) can be achieved. Shielding plates and shielding connection kits are available for EMC-compliant wiring. SINAMICS - simply my drive.
€ 469,28 exkl. USt.
SINAMICS PM240-2, 3AC 380-480 V, 0.55 kW, IP20 / UL open type, FSA, A – 6SL32101PE118AL1 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Netzspannung | 380..480 V | Eingangsphasenzahl | 3 |
| Einsatz im Wohn- und Gewerbebereich zulässig | Nein | Max. abgegebene Leistung bei quadrat. Belastung bei Bemessungsausgangsspannung | 0.55 kW |
| Ausgangsphasenzahl | 3 | Nennausgangsstrom I2N | 1.7 A |
| Max. Ausgangsfrequenz | 550 Hz | Tiefe | 165 mm |
| Relative symmetrische Netzfrequenztoleranz | 5 % | Bremschopper integriert | Ja |
| Max. abgegebene Leistung bei linearer Belastung bei Bemessungsausgangsspannung | 0.37 kW | Einsatz im Industriebereich zulässig | Ja |
| Höhe | 196 mm | Relative symmetrische Netzspannungstoleranz | 10 % |
| 4-Quadrantenbetrieb möglich | Nein | Breite | 73 mm |