Frequency inverter DA1 3Ph. 400VAC 72A/37kW, Filter, IP20 – 197497
€ 5.146,17 exkl. USt.
Frequency inverter DA1 3Ph. 400VAC 72A/37kW, Filter, IP20 – 197497 is backordered and will ship as soon as it is back in stock.
Variable frequency drive, type identifier (e.g. DIL): DA1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage at Ue: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-10%) - 480 (+10%) V, Rated operational current at 150% overload: Ie = 72 A, Note: Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Associated rated operational power Note: for normal, internally and externally ventilated, 4-pole, three-phase asynchronous motors with 1500 rpm –1 at 50 Hz or 1800 rpm –1 at 60 Hz
€ 5.146,17 exkl. USt.
Frequency inverter DA1 3Ph. 400VAC 72A/37kW, Filter, IP20 – 197497 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Power consumption | 925 W | Number of digital outputs | 2 |
| Permitted for use in residential and commercial areas | Yes | Supports protocol for Data-Highway | No |
| Supports protocol for DeviceNet | Yes | With PC connection | Yes |
| With control element | Yes | Supports protocol for EtherNet/IP | Yes |
| Supports protocol for BACnet | No | Number of HW interfaces serial RS-485 | 1 |
| With optical interface | No | Width | 234 mm |
| Number of analogue outputs | 2 | Permitted for use in industrial areas | Yes |
| Supports protocol for MODBUS | Yes | Supports protocol for SUCONET | No |
| Supports protocol for LON | No | Supports protocol for SERCOS | No |
| Number of HW interfaces serial RS-422 | 0 | Type of converter | U-converter |
| Supports protocol for PROFIBUS | Yes | Number of HW interfaces parallel | 0 |
| Max. output frequency | 500 Hz | Max. output voltage | 500 V |
| Rated output current I2N | 72 A | Supports protocol for TCP/IP | Yes |
| Supports protocol for DeviceNet Safety | No | Supports protocol for PROFIsafe | No |
| Number of HW interfaces serial RS-232 | 0 | Output phase number | 3 |
| Max. output power at quadratic load at rated output voltage | 37 kW | Max. output power at linear load at rated output voltage | 37 kW |
| Supports protocol for Foundation Fieldbus | No | Depth | 261 mm |
| Supports protocol for KNX | No | Supports protocol for AS-Interface Safety at Work | No |
| Supports protocol for INTERBUS-Safety | No | Supports protocol for other bus systems | Yes |
| Number of Industrial Ethernet HW interfaces | 0 | Degree of protection (IP) | IP20 |
| Input phase number | 3 | Number of analog inputs | 2 |
| Number of digital inputs | 5 | Supports protocol for ASI | No |
| Number of HW interfaces serial TTY | 0 | Number of HW interfaces USB | 0 |
| Number of other HW interfaces | 0 | Mains frequency | 50/60 Hz |
| Relative symmetrical mains frequency tolerance | 10 % | 4-quadrant operation possible | Yes |
| Degree of protection (NEMA) | other | Mains voltage | 380..480 V |
| Supports protocol for CAN | Yes | Supports protocol for INTERBUS | No |
| Supports protocol for PROFINET IO | Yes | Supports protocol for SafetyBUS p | No |
| Height | 485 mm | Relative symmetrical mains voltage tolerance | 10 % |
| Supports protocol for PROFINET CBA | No | Number of PROFINET interfaces | 0 |
| Brake chopper integrated | Yes |