Plant construction, mechanical engineering, heating and air-conditioning technology, conveying and transport systems, in EMC-critical environments (electromagnetic compatibility), space-saving due to small cable diameters, high electrical safety due to 4 kV test voltage, fine-wire strand made of bare copper wires, PVC core insulation LAPP P8/1, PVC inner sheath, grey, copper braiding, tinned, PVC outer sheath, transparent, cores twisted in layers, VDE Reg. No. 7030, flame-retardant according to IEC 60332-1-2, good chemical resistance, high degree of shielding coverage, low coupling resistance (max. 250 Ω/km at 30 MHz),
€ 11,68 exkl. USt.
ÖLFLEX CLASSIC 110 CY 2X10 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Conductor material | Copper | Screen over stranding element | none |
| Core identification | Numerals | Flame retardant according to IEC 60332-3-25 (Cat D) | No |
| Nominal voltage U | 500 V | Sheath material | Polyvinyl chloride (PVC) |
| Core insulation specification | other | With protective conductor | No |
| Flame retardant according to IEC 60332-3-22 (Cat A) | No | Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Min. permissible bending radius, flexible use/free movement | 328 mm | Halogen-free according to EN IEC 60754-1 | No |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No | Low smoke according to EN IEC 61034-2 | No |
| Flame retardant according to IEC 60332-1-2 | Yes | Oil resistant according to EN IEC 60811-404 | No |
| Conductor surface | bare | Stranding element | no |
| Fire behavior according to EN 13501-6: Smoke development | none | Outer diameter approx. | 16.4 mm |
| Permissible external cable temperature after installation without vibration | -40..80 °C | Material of core insulation | Polyvinyl chloride (PVC) |
| Min. permissible bending radius, stationary use/fixed installation | 98.4 mm | Number of cores | 2 |
| Halogen-free according to EN IEC 60754-2 | No | Sheath color | other |
| Flame retardant according to IEC 60332-3-24 (Cat C) | No | Fire behavior according to EN 13501-6: Droplet formation | none |
| Cold resistant according to EN 60811-504+505+506 | No | Permissible external cable temperature during installation/handling | -15..70 °C |
| Torsion protection | No | Halogen-free according to EN IEC 60754-3 | No |
| Fire behavior according to EN 13501-6: Class | Eca | Fire behavior according to EN 13501-6: Acid development | none |
| Nominal conductor cross-section | 10 mm² | Conductor class | Class 5 = fine-stranded |
| Screen over stranding | Braid | Supporting element | none |
| Sheath material specification | other | Cable geometry | round |
| Nominal voltage U0 | 300 V |