ÖLFLEX CLASSIC 130 H 5X1.5 Cut length
€ 3,53 exkl. USt.
ÖLFLEX CLASSIC 130 H 5X1.5 Cut length is backordered and will ship as soon as it is back in stock.
Public buildings such as airports or train stations, plant construction, mechanical engineering, heating and air conditioning technology, event technology, especially where people, animals, and high material assets are highly endangered by fire consequences in the event of a fire. Note: Use of AWM (Appliance Wiring Material) type cables in industrial machines (USA) according to NFPA 79 Ed. 2015: see catalog appendix table T29, Simple installation due to flexible design, Certified for maritime use, Fine-stranded bare copper wires, Core insulation: Halogen-free, Sheath: Halogen-free special compound, grey (similar to RAL 7001), Cores twisted in layers, UL AWM approval: see data sheet, Based on EN 50525-3-11, Based on EN 50525-2-51, Germanischer Lloyd (GL) Certificate No. TAE00002RJ, Flame retardant according to IEC 60332-1-2 (flame spread on a single cable), No flame propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame spread on vertical cable or wire bundles), Halogen-free according to IEC 60754-1 (proportion of halogen acid gases) Corrosivity of combustion gases according to IEC 60754-2 (acidity degree), Low smoke density according to IEC 61034-2,
€ 3,53 exkl. USt.
ÖLFLEX CLASSIC 130 H 5X1.5 Cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Flame-retardant according to IEC 60332-3-23 (Cat B) | No | Fire behavior according to EN 13501-6: Droplet formation | d1 |
| Screen over stranding element | none | Number of cores | 5 |
| Sheath material | other | Flame-retardant according to IEC 60332-1-2 | Yes |
| Rated voltage U | 500 V | Cable geometry | round |
| Torsion protection | No | Flame-retardant according to IEC 60332-3-24 (Cat C) | No |
| Permissible external cable temperature after installation without vibration | -40..80 °C | Nominal conductor cross-section | 1.5 mm² |
| Sheath color | grey | Halogen-free according to EN IEC 60754-1 | Yes |
| Fire behavior according to EN 13501-6: Class | Dca | Stranding element | no |
| Sheath material specification | other | Flame-retardant according to IEC 60332-3-25 (Cat D) | Yes |
| Min. permissible bending radius, flexible application/free movement | 124.5 mm | Fire behavior according to EN 13501-6: Acid development | a1 |
| Min. permissible bending radius, stationary application/fixed installation | 33.2 mm | Core insulation specification | other |
| Flame-retardant according to IEC 60332-3-22 (Cat A) | Yes | Cold-resistant according to EN 60811-504+505+506 | Yes |
| Low smoke according to EN IEC 61034-2 | Yes | Halogen-free according to EN IEC 60754-2 | No |
| Fire behavior according to EN 13501-6: Smoke development | s1b | Outer diameter approx. | 8.3 mm |
| Conductor surface | bare | Screen over stranding | none |
| Core insulation material | other | Flame-retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Oil-resistant according to EN IEC 60811-404 | No | Rated voltage U0 | 300 V |
| Conductor class | Class 5 = fine-stranded | Core identification | Digits |
| With protective conductor | No | Strain relief element | none |
| Halogen-free according to EN IEC 60754-3 | No | Conductor material | Copper |
| AWG size | 16 | Permissible external cable temperature during installation/handling | -25..70 °C |