ÖLFLEX CLASSIC 110 H 4G10 cut length
€ 23,89 exkl. USt.
ÖLFLEX CLASSIC 110 H 4G10 cut length is backordered and will ship as soon as it is back in stock.
Public buildings, such as airports or railway stations, For use within the framework of the European Construction Products Regulation (CPR) intended4, Plant construction, Mechanical engineering, Heating and air conditioning technology, Event technology, Especially where, in the event of fire, people, animals, and high material assets are highly endangered by fire consequences, Note: Use of AWM (Appliance Wiring Material) type cables in industrial machinery (USA) according to NFPA 79 Ed. 2015: see catalog appendix table T29, Easy handling and installation due to very flexible design, Wide range of applications due to excellent product properties, Certified for maritime use, Fine-stranded conductor made of bare copper wires, Core insulation: Halogen-free, Sheath: Halogen-free special mixture, grey (similar to RAL 7001), Cores stranded in layers, UL AWM style 21089, Based on EN 50525-3-11, Based on EN 50525-2-51, Germanischer Lloyd (GL) Certificate No. 11 119-14 HH, Flame-retardant according to IEC 60332-1-2 (flame spread on a single cable), No flame propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame propagation on vertical cable or conductor bundles), Halogen-free according to IEC 60754-1 (proportion of halogen acid gases), Corrosivity of fire gases according to IEC 60754-2 (acidity degree), Low smoke density according to IEC 61034-2, Oil-resistant according to EN 50363-4-1 (TM5) as well as UL OIL RES I and OIL RES II, UV and weather-resistant according to ISO 4892-2, Ozone-resistant according to EN 50396
€ 23,89 exkl. USt.
ÖLFLEX CLASSIC 110 H 4G10 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Screen over stranding element | None | Core identification | Numbers |
| With protective conductor | Yes | Flame retardant according to IEC 60332-3-24 (Cat C) | Yes |
| Min. permissible bending radius, stationary use/fixed installation | 64.8 mm | Nominal cross-section of conductor | 10 mm² |
| Rated voltage U | 500 V | Screen over stranding | None |
| Halogen-free according to EN IEC 60754-1 | Yes | Fire performance according to EN 13501-6: Smoke development | s1 |
| Fire performance according to EN 13501-6: Class | Cca | Conductor surface | Bare |
| Core insulation specification | Other | Cold resistant according to EN 60811-504+505+506 | Yes |
| Sheath material specification | Other | Fire performance according to EN 13501-6: Droplet formation | d1 |
| Outer diameter approx. | 16.2 mm | Permissible cable outer temperature during assembly/handling | -30..70 °C |
| Conductor class | Class 5 = fine-stranded | Cable geometry | Round |
| Permissible cable outer temperature after installation without vibration | -40..80 °C | AWG size | 8 |
| Sheath color | Grey | Rated voltage U0 | 300 V |
| Core insulation material | Other | Sheath material | Other |
| Flame retardant according to IEC 60332-1-2 | Yes | Conductor material | Copper |
| Number of cores | 4 | Screen | No |
| Flame retardant according to IEC 60332-3-22 (Cat A) | Yes | Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Halogen-free according to EN IEC 60754-3 | No | Low smoke according to EN IEC 61034-2 | Yes |
| Oil resistant according to EN IEC 60811-404 | Yes | Min. permissible bending radius, flexible use/free movement | 162 mm |
| Stranding element | No | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Fire performance according to EN 13501-6: Acid development | a1 |