• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

LAPP  Art.Nr: 15432962474315

H05V-K 1X1 WH Ring 100 m

Regular price
Regular price € 25,77 inkl. USt.
€ 21,48 exkl. USt.
Unit price€ 257,70 /1000m
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Internal wiring of equipment, Protected installation in and on luminaires, signalling systems on and under plaster in conduits, The marking on cables and wires also stands for international recognition of test marks/proofs from national certification institutes, e.g. in the form . The marking is used in trade between European countries, Fine-stranded copper conductor made of bare copper wires according to strand class 5 acc. to IEC 60228/ VDE 0295, PVC-based core insulation, -Type certification according to EN 505525-2-31/ VDE 0285-525-2-31, Flame retardant according to IEC 60332-1-2, Spool: d1=18mm, d2=200mm, b=85mm,

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

AWG size 18 Conductor material Copper
Fire behaviour according to EN 13501-6: Droplet formation None Conductor diameter 1.13 mm
Core identification Colour Rated voltage U0 300 V
Rated voltage U 500 V Flame retardant according to IEC 60332-1-2 Yes
Halogen-free according to EN IEC 60754-2 No Conductor class Class 5 = fine-stranded
Conductor surface Bare Oil resistant according to EN IEC 60811-404 No
Cold resistant according to EN 60811-504+505+506 No Core insulation material Polyvinyl chloride (PVC)
Flame retardant according to IEC 60332-3-24 (Cat C) No Core colour White
Flame retardant according to IEC 60332-3-21 (Cat A F/R) No Flame retardant according to IEC 60332-3-25 (Cat D) No
Low smoke according to EN IEC 61034-2 No Fire behaviour according to EN 13501-6: Smoke development None
Outer diameter approx. 2.8 mm Max. permissible conductor temperature 70 °C
Flame retardant according to IEC 60332-3-22 (Cat A) No Fire behaviour according to EN 13501-6: Class Eca
Nominal conductor cross-section 1 mm² Flame retardant according to IEC 60332-3-23 (Cat B) No
Halogen-free according to EN IEC 60754-1 No Halogen-free according to EN IEC 60754-3 No
Fire behaviour according to EN 13501-6: Acid development None