EATON
Art.Nr: 15433036497227
12/24V UC, Control Relay 8I/8R Ext. – 197218
Regular price
Regular price
€ 157,88
inkl. USt.
€ 131,57 exkl. USt.
€ 131,57 exkl. USt.
Unit price
Verfügbarkeit wird geladen …
12/24V UC, Control Relay 8I/8R Ext. – 197218 is backordered and will ship as soon as it is back in stock.
I/O expansion, Supply voltage: 12/24 V DC, 24 V AC, Can be used via easyConnect, Mounting position: Vertical or horizontal, Degree of protection (IEC/EN 60529, EN50178, VBG 4): IP20, Standards and regulations: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 61131-2, EN 61010, EN 50178, cULus according to UL 61010, CSA C22.2 No. 61010
EATON
Art.Nr: 15433036497227
Regular price
Regular price
€ 157,88
inkl. USt.
€ 131,57 exkl. USt.
€ 131,57 exkl. USt.
Unit price
12/24V UC, Control Relay 8I/8R Ext. – 197218 is backordered and will ship as soon as it is back in stock.
Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Technische Parameter
Technische Parameter
| With relay output | Yes | Supports protocol for MODBUS | Yes |
| Supports protocol for Data-Highway | No | Supports protocol for SUCONET | No |
| With timer | No | Suitable for safety functions | No |
| Height | 90 mm | Power consumption | 3 W |
| Supports protocol for ASI | No | Explosion protection category for dust | None |
| Certified for UL hazardous area Division 2 | Yes | Certified for UL hazardous area Group E (metal dusts) | No |
| Switching current | 5 A | Number of HW interfaces serial TTY | 0 |
| Number of HW interfaces USB | 0 | Number of HW interfaces Wireless | 0 |
| Supports protocol for KNX | No | Supports protocol for INTERBUS-Safety | No |
| Base unit | No | Associated equipment (Ex ia) | No |
| With optical interface | No | Radio standard Bluetooth | No |
| Radio standard GSM | No | Redundancy capability | No |
| Front mounting possible | Yes | Rack mounting possible | No |
| Certified for UL hazardous area Division 1 | No | Performance Level according to EN ISO 13849-1 | None |
| Certified for UL hazardous area Class III | No | Number of HW interfaces serial RS-422 | 0 |
| Supports protocol for DeviceNet Safety | No | Supports protocol for PROFIsafe | No |
| With display | No | Certified for UL hazardous area Class II | No |
| Certified for UL hazardous area Group F (carbonaceous dusts) | No | Supply voltage AC 60 Hz | 85..264 V |
| Number of analogue outputs | 0 | Number of digital inputs | 8 |
| Number of HW interfaces parallel | 0 | Number of other HW interfaces | 0 |
| Supports protocol for TCP/IP | Yes | Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No | Suitable for DIN rail mounting | Yes |
| Wall/direct mounting possible | Yes | Certified for UL hazardous area Group A (acetylene) | No |
| Width | 72 mm | Depth | 58 mm |
| Number of analogue inputs | 0 | Supports protocol for LON | No |
| Supports protocol for SafetyBUS p | No | Supports protocol for other bus systems | No |
| IO-Link Master | No | Degree of protection (IP) | IP20 |
| Associated equipment (Ex ib) | No | Certified for UL hazardous area Group D (propane) | Yes |
| Type of supply voltage | AC/DC | Number of PROFINET interfaces | 0 |
| Number of HW interfaces serial RS-232 | 0 | Supports protocol for CAN | No |
| Supports protocol for PROFINET IO | No | Supports protocol for SERCOS | No |
| Supports protocol for EtherNet/IP | No | Supports protocol for AS-Interface Safety at Work | No |
| SIL according to IEC 61508 | None | Certified for UL hazardous area Group B (hydrogen) | Yes |
| Certified for UL hazardous area Group C (ethylene) | Yes | Number of HW interfaces serial RS-485 | 0 |
| Supports protocol for EtherCAT | No | Extension unit | Yes |
| Supply voltage AC 50 Hz | 85..264 V | Supply voltage DC | 10.2..28.8 V |
| Number of digital outputs | 8 | Number of industrial Ethernet HW interfaces | 0 |
| Supports PROFIBUS protocol | No | Supports INTERBUS protocol | No |
| Supports DeviceNet protocol | No | Supports PROFINET CBA protocol | No |
| Supports Foundation Fieldbus protocol | No | 3G (UMTS) mobile communication standard | No |
| Expandable | Yes | Explosion protection category for gas | none |
| Certified for UL hazardous area Class I | Yes | Certified for UL hazardous area Group G (non-conductive dusts) | No |