ÖLFLEX CLASSIC 110 CY 2X1 Cut length
€ 2,23 exkl. USt.
ÖLFLEX CLASSIC 110 CY 2X1 Cut length is backordered and will ship as soon as it is back in stock.
Plant construction, mechanical engineering, heating and air-conditioning technology, conveying and transport systems, in EMC-critical environments (electromagnetic compatibility), space-saving due to small cable diameters, high electrical safety due to 4 kV test voltage, fine-wire strand of bare copper wires, PVC core insulation LAPP P8/1, PVC inner sheath, grey, copper braiding, tinned, outer sheath made of PVC, transparent, cores twisted in layers, VDE Reg. No. 7030, flame-retardant according to IEC 60332-1-2, good chemical resistance, high coverage of the shield, low coupling resistance (max. 250 Ω/km at 30 MHz),
€ 2,23 exkl. USt.
ÖLFLEX CLASSIC 110 CY 2X1 Cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Sheath material specification | Other | Sheath colour | Other |
| Flame retardant according to IEC 60332-3-22 (Cat A) | No | Halogen-free according to EN IEC 60754-3 | No |
| Permissible outer cable temperature during assembly/handling | -5..70 °C | Halogen-free according to EN IEC 60754-2 | No |
| Fire performance according to EN 13501-6: acid development | None | Min. permissible bending radius, flexible use with guided motion | 237 mm |
| Permissible outer cable temperature after installation without vibration | -40..80 °C | Stranding element | No |
| Shield | Yes | Flame retardant according to IEC 60332-3-25 (Cat D) | No |
| Low smoke according to EN IEC 61034-2 | No | Conductor surface | Bare |
| Nominal conductor cross-section | 1 mm² | Shield over stranding | Braid |
| Flame retardant according to IEC 60332-1-2 | Yes | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No | Oil-resistant according to EN IEC 60811-404 | No |
| Nominal voltage U0 | 300 V | Nominal voltage U | 500 V |
| Supporting element | None | Torsion protection | No |
| With protective conductor | No | Cold-resistant according to EN 60811-504+505+506 | Yes |
| Core insulation material | Polyvinyl chloride (PVC) | Core insulation specification | Other |
| Core identification | Numbers | Number of cores | 2 |
| Cable geometry | Round | Fire performance according to EN 13501-6: smoke development | None |
| Conductor class | Class 5 = fine-strand | Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Conductor material | Copper | Halogen-free according to EN IEC 60754-1 | No |
| Fire performance according to EN 13501-6: dripping behavior | None | Outer diameter approx. | 7.9 mm |
| Shield over stranding element | None | Fire performance according to EN 13501-6: class | Eca |
| Sheath material | Polyvinyl chloride (PVC) | Min. permissible bending radius, flexible use/free movement | 158 mm |
| Min. permissible bending radius, stationary use/fixed installation | 47.4 mm |