ÖLFLEX CLASSIC 110 2X0.75 Cut Length
€ 0,68 exkl. USt.
ÖLFLEX CLASSIC 110 2X0.75 Cut Length is backordered and will ship as soon as it is back in stock.
Fixed installation as well as occasional flexible use without tensile stress in free, non-continuously recurring movement, Dry or damp rooms, with normal mechanical stress, Suitable for torsion applications typical in the loop of wind turbines (WTG), In power chains for travel distances up to 5 m and 0.2 ... 1 million bending cycles, for the following dimensions: 0.5 to 2.5 mm² and 2 to 7 cores, Wide range of standardized lengths and individual cuts, Very wide range of articles, Versions with up to 100 cores, Fine-wire strand of bare copper wires, PVC core insulation LAPP P8/1, Cores stranded in layers, Sheath: PVC, grey (similar to RAL 7001), VDE Reg. No. 7030 for the following dimensions: up to 2.5 mm²: 2 - 65 cores from 4 mm²: 2 - 7 cores from 25 mm²: 2 - 5 cores, Flame-retardant according to IEC 60332-1-2, Good chemical resistance, Oil-resistant according to DIN EN 50290-2-22 (TM54),
€ 0,68 exkl. USt.
ÖLFLEX CLASSIC 110 2X0.75 Cut Length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Conductor surface | bare | Sheath colour | grey |
| Outer diameter approx. | 5.4 mm | Low smoke according to EN IEC 61034-2 | No |
| Halogen-free according to EN IEC 60754-2 | No | Fire behaviour according to EN 13501-6: smoke development | none |
| Screen over stranding element | none | With protective conductor | No |
| Min. permissible bending radius, stationary use/fixed installation | 21.6 mm | Permissible external cable temperature during installation/handling | -5..70 °C |
| Conductor material | copper | Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Oil resistant according to EN IEC 60811-404 | No | Nominal voltage U0 | 300 V |
| Core identification | digits | Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Fire behaviour according to EN 13501-6: Class | Eca | Support element | none |
| Flame retardant according to IEC 60332-1-2 | Yes | Permissible external cable temperature after installation without vibration | -40..80 °C |
| Conductor class | Class 5 = fine-stranded | Number of cores | 2 |
| Core insulation material | Polyvinyl chloride (PVC) | Sheath material specification | other |
| Halogen-free according to EN IEC 60754-3 | No | Sheath material | Polyvinyl chloride (PVC) |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No | Cold resistant according to EN 60811-504+505+506 | No |
| Stranding element | No | Cable geometry | round |
| Halogen-free according to EN IEC 60754-1 | No | Min. permissible bending radius, flexible use/free movement | 54 mm |
| Nominal conductor cross-section | 0.75 mm² | Shield over stranding | none |
| Shield | No | Fire behaviour according to EN 13501-6: Acid development | none |
| Min. permissible bending radius, flexible use with forced guidance | 81 mm | Nominal voltage U | 500 V |
| Conductor shape | round | Core insulation specification | other |
| Torsion protection | No | Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | No | Fire behaviour according to EN 13501-6: Droplet behaviour | none |