For fixed installation and occasional flexible use without tensile stress during free, non-continuously recurring movement, dry or damp rooms, with normal mechanical stress, suitable for torsional applications typical in the loop of wind turbines (WTGs), in power chains for travel distances up to 5 m and 0.2 ... 1 million bending cycles, for the following dimensions: 0.5 to 2.5 mm² and 2 to 7 cores, large range of standardized lengths and custom cuts, very large product range, versions with up to 100 cores, fine-stranded conductor of bare copper wires, PVC core insulation LAPP P8/1, cores stranded in layers, jacket: PVC, grey (similar to RAL 7001), VDE Reg. No. 7030 for the following dimensions: up to 2.5 mm²: 2 - 65 cores from 4 mm²: 2 - 7 cores from 25 mm²: 2 - 5 cores, flame-retardant according to IEC 60332-1-2, good chemical resistance, oil-resistant according to DIN EN 50290-2-22 (TM54),
€ 6,81 exkl. USt.
ÖLFLEX CLASSIC 110 4G6 Cut Length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Conductor surface | bare | With protective conductor | Yes |
| Sheath colour | grey | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Oil resistant according to EN IEC 60811-404 | No | Nominal voltage U | 500 V |
| Material of core insulation | Polyvinyl chloride (PVC) | Cable geometry | round |
| Permissible cable outer temperature during assembly/handling | -15..70 °C | Nominal cross section of conductor | 6 mm² |
| Number of cores | 4 | Sheath material specification | other |
| Flame retardant according to IEC 60332-3-25 (Cat D) | No | Fire behaviour according to EN 13501-6: Smoke development | none |
| Conductor shape | round | Core identification | Numbers |
| Halogen free according to EN IEC 60754-2 | No | Conductor class | Class 5 = fine-stranded |
| Torsion protection | No | Halogen free according to EN IEC 60754-3 | No |
| Shield | No | Flame retardant according to IEC 60332-1-2 | Yes |
| Halogen free according to EN IEC 60754-1 | No | Fire behaviour according to EN 13501-6: Acid evolution | none |
| Screen over stranding | none | Min. permissible bending radius, stationary use/fixed installation | 52 mm |
| Sheath material | Polyvinyl chloride (PVC) | Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Low smoke according to EN IEC 61034-2 | No | Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Fire behaviour according to EN 13501-6: Class | Eca | Cold resistant according to EN 60811-504+505+506 | No |
| Min. permissible bending radius, flexible use with guided movement | 195 mm | Conductor material | Copper |
| Core insulation specification | other | Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Fire behaviour according to EN 13501-6: Droplet formation | none | Outer diameter approx. | 13 mm |
| Min. permissible bending radius, flexible use/free movement | 130 mm | Permissible cable outer temperature after assembly without vibration | -40..80 °C |
| Nominal voltage U0 | 300 V | Screen over element | none |
| Stranding element | no | Carrier element | none |