ÖLFLEX CLASSIC 100 450/750V 5G4 Cut Length
€ 6,45 exkl. USt.
ÖLFLEX CLASSIC 100 450/750V 5G4 Cut Length is backordered and will ship as soon as it is back in stock.
Plant engineering, Mechanical engineering, Heating and air-conditioning technology, Power plant technology, Dry or damp rooms, under normal mechanical stress, Fixed installation and occasional flexible use without tensile stress with free, non-continuously recurring movement, Suitable for torsion applications typical in the loops of wind turbines (WTG), High electrical safety due to 4 kV test voltage, Good flexibility due to core stranding with short lay length, Fine-wire strand of bare copper wires, PVC core insulation LAPP P8/1, Cores twisted in layers, Sheath: PVC, grey (similar to RAL 7001), Based on IEC 60227-5 and EN 50525-2-51, Flame retardant according to IEC 60332-1-2, Good chemical resistance,
€ 6,45 exkl. USt.
ÖLFLEX CLASSIC 100 450/750V 5G4 Cut Length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Sheath material specification | other | Min. permissible bending radius, stationary use/permanently installed | 54.8 mm |
| Conductor class | Class 5 = fine-stranded | Core identification | Color |
| Support element | none | Screen | No |
| Torsion protection | No | Flame retardant according to IEC 60332-3-25 (Cat D) | No |
| Fire performance according to EN 13501-6: Smoke development | none | Cold resistant according to EN 60811-504+505+506 | Yes |
| Conductor material | Copper | Nominal voltage U | 750 V |
| Number of cores | 5 | Outer diameter approx. | 13.7 mm |
| Nominal conductor cross-section | 4 mm² | Flame retardant according to IEC 60332-1-2 | Yes |
| Halogen-free according to EN IEC 60754-2 | No | Core insulation material | Polyvinyl chloride (PVC) |
| Core insulation specification | other | Sheath material | Polyvinyl chloride (PVC) |
| Low smoke according to EN IEC 61034-2 | No | Fire performance according to EN 13501-6: Acid development | none |
| Oil resistant according to EN IEC 60811-404 | No | Screen over stranding | none |
| Halogen-free according to EN IEC 60754-3 | No | Screen over stranding element | none |
| Permissible cable outer temperature during installation/handling | -5..70 °C | Stranding element | no |
| Sheath color | grey | Fire performance according to EN 13501-6: Class | Eca |
| Fire performance according to EN 13501-6: Dripping behavior | none | Permissible cable outer temperature after installation without vibration | -40..80 °C |
| Conductor surface | bare | Nominal voltage U0 | 450 V |
| With protective conductor | Yes | Cable geometry | round |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No | Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-24 (Cat C) | No | Halogen-free according to EN IEC 60754-1 | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No | Min. permissible bending radius, flexible use/free movement | 205.5 mm |