• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

SCHNEIDER ELECTRIC  Art.Nr: 15432837366091

Direct-on-line starter enclosed, TeSys LE1-D, 18A, coil 230V AC – LE1D18P7

Regular price
Regular price € 131,12 inkl. USt.
€ 109,27 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Direct starters with magnetic trip up to 15 kWThe combination of TeSys GV2 motor circuit breakers and TeSys D contactors guarantees maximum reliability, compact designs, and simplest selection.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Rated control supply voltage AC 50 Hz 230..230 V Rated power, 460 V, 60 Hz, 3-phase 7.5 kW
Supports protocol for SUCONET No Supports protocol for EtherNet/IP No
Supports protocol for TCP/IP No With short-circuit release No
Supports protocol for DeviceNet No Supports protocol for SERCOS No
Ambient temperature, upper limit without restrictions 40 °C Supports protocol for MODBUS No
Supports protocol for Data-Highway No Supports protocol for PROFINET CBA No
Supports protocol for AS-Interface Safety at Work No Supports protocol for SafetyBUS p No
Type of motor starter Direct-on-line starter (DOL) Rated operating power at AC-3, 230 V, 3-phase 4 kW
Number of auxiliary contacts as normally open contact 0 Supports protocol for PROFIBUS No
Suitable for DIN rail mounting No Number of indicator lights 0
External reset possible Yes Degree of protection (IP) IP65
Depth 153.5 mm Number of auxiliary contacts as normally closed contact 0
Type of connection main circuit Screw connection Type of electrical connection for auxiliary and control circuit Screw connection
Number of control positions 2 With fuse No
Supports protocol for PROFIsafe No Voltage type for actuation AC
Rated operational current at AC-3, 400 V 18 A Suitable for EMERGENCY STOP No
Supports protocol for INTERBUS No Rated control supply voltage AC 60 Hz 230..230 V
Rated operational current Ie 18 A With transformer No
Supports protocol for CAN No Supports protocol for ASI No
Supports protocol for other bus systems No Height 201 mm
Rated power, 575 V, 60 Hz, 3-phase 11 kW Supports protocol for Foundation Fieldbus No
Supports protocol for INTERBUS-Safety No Width 101 mm
Rated operational power at AC-3, 400 V 7.5 kW Supports protocol for LON No
Supports protocol for PROFINET IO No Supports protocol for DeviceNet Safety No