• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

SCHNEIDER ELECTRIC  Art.Nr: 15432822325579

Variable speed drive, ATV930, 4kW, 400/480V, with brake module, IP21 – ATV930U40N4

Regular price
Regular price € 1.567,68 inkl. USt.
€ 1.306,40 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Altivar 900 Process frequency inverter - Inverter for moving solids & mechanics, e.g. crushers, mixers, extruders, conveyor belts, cranes. Wall mounting. Frequency inverter ATV930, with braking module. Dimensions 144 x 350 x 206 mm, power 4 kW. Supply voltage, three-phase 380-480 V 50/60 Hz. Output frequency 0.1-500 Hz. Overload in normal operation 120% for 60s, overload in high overload mode 150% for 60s (with derating by one power class). Control types asynchronous motors, constant torque, variable torque, optimized torque mode, synchronous PM (Permanent Magnet) motor. Integrated web server with direct access to system configuration and monitoring, easy master/slave coupling via Ethernet, with load balancing. Application functions for e.g. conveyor belts or cranes. Continuous and historical real-time measurements with customizable dashboards. Integrated safety function STO (Safe Torque Off) SIL3. Number of integrated I/O Analog inputs 2 analog differential inputs, logic inputs 8, relay outputs 3, analog outputs 2. Integrated communication Ethernet-based (with 2 ports, internally switched) Modbus/TCP, Ethernet/IP. Serial communication Modbus RS485 interface. Configuration and operating elements Decentralized graphical operating terminal, integrated web server, DTM (Device Type Manager), SoMove software. Optional I/O expansion cards, relay output cards. Optional communication cards (CANopen Daisy Chain RJ45, Sub-D and screw terminals, ProfiNet, Profibus DP V1, EtherCAT and DeviceNet).

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Mains voltage 380..480 V Mains frequency 50/60 Hz
Supports EtherNet/IP protocol Yes Number of serial TTY HW interfaces 0
With PC connection No Number of digital inputs 8
Use in industrial area permitted Yes Use in residential and commercial areas permitted Yes
Supports MODBUS protocol No Degree of protection (IP) IP21
Number of digital outputs 1 Supports DeviceNet protocol Yes
Supports SERCOS protocol No Number of PROFINET interfaces 0
Number of USB hardware interfaces 0 Type of converter VSD
Relative symmetrical mains frequency tolerance 5 % Supports AS-Interface Safety at Work protocol No
Number of serial RS-485 hardware interfaces 3 Brake chopper integrated No
Supports PROFIsafe protocol No Output phase number 3
Number of analog outputs 2 With control element Yes
Supports PROFINET CBA protocol No Supports INTERBUS-Safety protocol No
Supports protocol for other bus systems Yes Number of Industrial Ethernet hardware interfaces 0
Number of serial RS-232 hardware interfaces 0 Width 144 mm
Rated output current I2N 9.3 A Max. output power at linear load at rated output voltage 4 kW
Supports KNX protocol No Supports SUCONET protocol No
Supports LON protocol No Supports PROFINET IO protocol Yes
Number of serial RS-422 hardware interfaces 0 Depth 206 mm
Max. output voltage 480 V Max. output power at quadratic load at rated output voltage 4 kW
Supports TCP/IP protocol No Supports CAN protocol Yes
Supports SafetyBUS p protocol No Number of other hardware interfaces 0
Supports PROFIBUS protocol Yes Number of parallel hardware interfaces 0
Height 350 mm Input phase number 3
Max. output frequency 500 Hz Supports INTERBUS protocol No
Supports ASI protocol No Supports DeviceNet Safety protocol No
Supports BACnet protocol No Relative symmetrical mains voltage tolerance 10 %
Number of analogue inputs 3 Supports Data-Highway protocol No
Supports Foundation Fieldbus protocol No With optical interface Yes
4-quadrant operation possible Yes