• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

ABB  Art.Nr: 15433204433227

MSMotor protection circuit breaker trip class 10 8.0 12A – 1SAM350000R1012

Regular price
Regular price € 133,91 inkl. USt.
€ 111,59 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
Motor starter protector MS132 with thermal and electromagnetic protection stands for the compact and powerful series with high short-circuit breaking capacity for motor protection up to 15 kW (400 V) with a module width of 45 mm. The temperature-compensated device has a rotary handle operation with a clear switch position indicator I/TRIP/0. In addition, the MS132 has a short-circuit indicator. The rotary handle can be directly locked in the 0-position with a padlock. Auxiliary, signal and short-circuit indication contacts, as well as undervoltage and shunt trips can be mounted without tools. 3-phase busbars for 65 A or for 100 A and infeed blocks for 25 mm² or 35 mm² allow common infeed for several motor starter protectors. Protective enclosures as well as accessories for control cabinet and door mounting complete the range. Atex certification allows the protection of motors in hazardous areas, UL approval as a >Self protected combination motor controller< extends the range of application in North America.>
Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

With integrated undervoltage release No Width 45 mm
Setting range of the instantaneous short-circuit release 180..180 A Degree of protection (IP) IP20
With thermal overload protection Yes Height 97.8 mm
Rated permanent current Iu 12 A Main circuit connection type Screw connection
Device construction type Complete device in housing With integrated auxiliary switch No
Overload release current setting 8..12 A Rated operational power at AC-3, 230 V 5.5 kW
Number of poles 3 Depth 86.55 mm
Phase failure sensitive Yes Release technology Thermomagnetic
Rated operational power at AC-3, 400 V 5.5 kW Power loss 6.9 W
Type of actuating element Rotary knob Rated operational voltage 250..690 V
Rated ultimate short-circuit breaking current Icu at 400 V, AC 100 kA