Measurement, control and regulation technology, office machinery and data processing systems, space-saving due to small cable diameters, fine-stranded conductors made of bare copper wires, PVC core insulation LAPP P8/1, wrapped with plastic foil, tinned copper braid, sheath: PVC, grey (similar to RAL 7001), cores twisted in layers, based on EN 505525-2-51, flame-retardant according to IEC 60332-1-2, good chemical resistance, high shielding coverage, low coupling resistance (max. 250 Ω/km at 30 MHz),
€ 3,20 exkl. USt.
ÖLFLEX CLASSIC 115 CY 5G1 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Torsion protection | No | Flame-retardant according to IEC 60332-3-24 (Cat C) | No |
| Halogen-free according to EN IEC 60754-2 | No | Fire behaviour according to EN 13501-6: Class | Eca |
| Min. permissible bending radius, stationary use/fixed installation | 48.6 mm | Cable geometry | round |
| Min. permissible bending radius, flexible use/free movement | 162 mm | Nominal conductor cross-section | 1 mm² |
| Supporting element | none | Flame-retardant according to IEC 60332-1-2 | Yes |
| Permissible external cable temperature after installation without vibration | -40..80 °C | Screen over stranding element | none |
| Sheath material | Polyvinyl chloride (PVC) | Sheath material specification | other |
| Outer diameter approx. | 8.1 mm | Conductor surface | bare |
| Number of cores | 5 | Core identification | digits |
| Flame-retardant according to IEC 60332-3-23 (Cat B) | No | Halogen-free according to EN IEC 60754-1 | No |
| Fire behaviour according to EN 13501-6: Droplet formation | none | Nominal voltage U0 | 300 V |
| With protective conductor | Yes | Flame-retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Oil-resistant according to EN IEC 60811-404 | No | Nominal voltage U | 500 V |
| Sheath colour | grey | Permissible external cable temperature during installation/handling | -5..70 °C |
| Screen over stranding | braid | Core insulation material | Polyvinyl chloride (PVC) |
| Flame-retardant according to IEC 60332-3-22 (Cat A) | No | Fire behaviour according to EN 13501-6: Smoke development | none |
| Cold-resistant according to EN 60811-504+505+506 | Yes | Core insulation specification | other |
| Low smoke according to EN IEC 61034-2 | No | Stranding element | no |
| Halogen-free according to EN IEC 60754-3 | No | Conductor material | Copper |
| Conductor class | Cl.5 = fine-stranded | Fire behaviour according to EN 13501-6: Acid development | none |
| Flame-retardant according to IEC 60332-3-25 (Cat D) | No |