LAPP  Art.Nr: 15433177006411

ÖLFLEX CLASSIC 110 H 7G0,75 cut length

Regular price
Regular price € 5,69 inkl. USt.
€ 4,74 exkl. USt.
Unit price€ 5.690,00 /1000m
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Public buildings, such as airports or train stations, Intended for use within the framework of the European Construction Products Regulation (CPR)4, Plant engineering, Mechanical engineering, HVAC technology, Event technology, Especially where people, animals, and high material assets are highly endangered by the consequences of fire, Note: Use of AWM (Appliance Wiring Material) type cables in industrial machines (USA) according to NFPA 79 Ed. 2015: see catalog appendix table T29, Easy handling and installation due to very flexible design, Wide range of applications due to excellent product properties, Certified for maritime use, Fine-stranded conductor made of bare copper wires, Core insulation: Halogen-free, Jacket: Halogen-free special compound, grey (similar to RAL 7001), Cores twisted in layers, UL AWM style 21089, In accordance with EN 50525-3-11, In accordance with EN 50525-2-51, Germanischer Lloyd (GL) Certificate No. 11 119-14 HH, Flame retardant according to IEC 60332-1-2 (flame propagation on a single cable), No flame propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame propagation on vertical cable or wire bundles), Halogen-free according to IEC 60754-1 (proportion of halogen acid-containing gases), Corrosivity of smoke gases according to IEC 60754-2 (degree of acidity), Low smoke density according to IEC 61034-2, Oil resistant according to EN 50363-4-1 (TM5) as well as UL OIL RES I and OIL RES II, UV and weather resistant according to ISO 4892-2, Ozone resistant according to EN 50396

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Flame retardant according to IEC 60332-3-22 (Cat A) Yes Shield over stranding element without
Fire behaviour according to EN 13501-6: Class Cca Fire behaviour according to EN 13501-6: Acid development a1
Conductor nominal cross-section 0.75 mm² Low smoke according to EN IEC 61034-2 Yes
Cold resistant according to EN 60811-504+505+506 Yes Min. permissible bending radius, stationary use/fixed installation 30 mm
Permissible cable outer temperature after assembly without vibration -40..80 °C Conductor material Copper
Conductor surface bare Shield over stranding without
Core insulation material other Torsion protection No
Flame retardant according to IEC 60332-3-25 (Cat D) Yes Stranding element no
Core insulation specification other Flame retardant according to IEC 60332-3-23 (Cat B) No
Fire behaviour according to EN 13501-6: Smoke development s1a Halogen-free according to EN IEC 60754-1 Yes
Outer diameter approx. 7.5 mm Permissible cable outer temperature during assembly/handling -30..70 °C
Core identification Numbers Supporting element without
Fire behaviour according to EN 13501-6: Droplet formation d1 With protective conductor Yes
Sheath colour grey Cable geometry round
Flame retardant according to IEC 60332-1-2 Yes Halogen-free according to EN IEC 60754-3 No
Oil resistant according to EN IEC 60811-404 Yes Number of cores 7
Sheath material other Nominal voltage U0 300 V
Conductor class Class 5 = fine-stranded Sheath material specification other
Min. permissible bending radius, flexible use/free movement 75 mm Nominal voltage U 500 V
AWG size 20 Shield No
Flame retardant according to IEC 60332-3-21 (Cat A F/R) No