ÖLFLEX CLASSIC 110 H 7G0,75 cut length
€ 4,74 exkl. USt.
ÖLFLEX CLASSIC 110 H 7G0,75 cut length is backordered and will ship as soon as it is back in stock.
Public buildings, such as airports or train stations, Intended for use within the framework of the European Construction Products Regulation (CPR)4, Plant engineering, Mechanical engineering, HVAC technology, Event technology, Especially where people, animals, and high material assets are highly endangered by the consequences of fire, Note: Use of AWM (Appliance Wiring Material) type cables in industrial machines (USA) according to NFPA 79 Ed. 2015: see catalog appendix table T29, Easy handling and installation due to very flexible design, Wide range of applications due to excellent product properties, Certified for maritime use, Fine-stranded conductor made of bare copper wires, Core insulation: Halogen-free, Jacket: Halogen-free special compound, grey (similar to RAL 7001), Cores twisted in layers, UL AWM style 21089, In accordance with EN 50525-3-11, In accordance with EN 50525-2-51, Germanischer Lloyd (GL) Certificate No. 11 119-14 HH, Flame retardant according to IEC 60332-1-2 (flame propagation on a single cable), No flame propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame propagation on vertical cable or wire bundles), Halogen-free according to IEC 60754-1 (proportion of halogen acid-containing gases), Corrosivity of smoke gases according to IEC 60754-2 (degree of acidity), Low smoke density according to IEC 61034-2, Oil resistant according to EN 50363-4-1 (TM5) as well as UL OIL RES I and OIL RES II, UV and weather resistant according to ISO 4892-2, Ozone resistant according to EN 50396
€ 4,74 exkl. USt.
ÖLFLEX CLASSIC 110 H 7G0,75 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Flame retardant according to IEC 60332-3-22 (Cat A) | Yes | Shield over stranding element | without |
| Fire behaviour according to EN 13501-6: Class | Cca | Fire behaviour according to EN 13501-6: Acid development | a1 |
| Conductor nominal cross-section | 0.75 mm² | Low smoke according to EN IEC 61034-2 | Yes |
| Cold resistant according to EN 60811-504+505+506 | Yes | Min. permissible bending radius, stationary use/fixed installation | 30 mm |
| Permissible cable outer temperature after assembly without vibration | -40..80 °C | Conductor material | Copper |
| Conductor surface | bare | Shield over stranding | without |
| Core insulation material | other | Torsion protection | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | Yes | Stranding element | no |
| Core insulation specification | other | Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Fire behaviour according to EN 13501-6: Smoke development | s1a | Halogen-free according to EN IEC 60754-1 | Yes |
| Outer diameter approx. | 7.5 mm | Permissible cable outer temperature during assembly/handling | -30..70 °C |
| Core identification | Numbers | Supporting element | without |
| Fire behaviour according to EN 13501-6: Droplet formation | d1 | With protective conductor | Yes |
| Sheath colour | grey | Cable geometry | round |
| Flame retardant according to IEC 60332-1-2 | Yes | Halogen-free according to EN IEC 60754-3 | No |
| Oil resistant according to EN IEC 60811-404 | Yes | Number of cores | 7 |
| Sheath material | other | Nominal voltage U0 | 300 V |
| Conductor class | Class 5 = fine-stranded | Sheath material specification | other |
| Min. permissible bending radius, flexible use/free movement | 75 mm | Nominal voltage U | 500 V |
| AWG size | 20 | Shield | No |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |