ÖLFLEX CLASSIC 110 CY 4G2.5 Cut Length
€ 4,68 exkl. USt.
€ 5,34 inkl. USt.
up to −7 % with the Black Friday offer. 5% deducted automatically in your cart, + 2% for prepayment with code VORKASSE2.
ÖLFLEX CLASSIC 110 CY 4G2.5 Cut Length is backordered and will ship as soon as it is back in stock.
Plant engineering, Mechanical engineering, Heating and air-conditioning technology, Conveying and transport systems, In EMC-critical environments (electromagnetic compatibility), Space-saving due to small cable diameter, High electrical safety due to 4 kV test voltage, Fine-stranded wire made of bare copper strands, PVC core insulation LAPP P8/1, PVC inner sheath, grey, Copper braiding, tinned, Outer sheath made of PVC, transparent, Cores twisted in layers, VDE Reg. No. 7030, Flame-retardant according to IEC 60332-1-2, Good chemical resistance, High degree of shielding coverage, low coupling resistance (max. 250 O/km at 30 MHz),
€ 4,68 exkl. USt.
ÖLFLEX CLASSIC 110 CY 4G2.5 Cut Length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Conductor material | Copper | Conductor surface | bare |
| Nominal conductor cross-section | 2.5 mm² | Conductor class | Class 5 = fine-stranded |
| Number of cores | 4 | Shield over stranding element | without |
| Stranding element | no | Shield over stranding | braid |
| Core insulation material | Polyvinyl chloride (PVC) | Core insulation specification | other |
| Core identification | Digits | With protective conductor | Yes |
| Supporting element | without | Sheath material | Polyvinyl chloride (PVC) |
| Sheath material specification | other | Sheath color | other |
| Shield | Yes | Cable geometry | round |
| Torsion protection | No | Flame retardant according to IEC 60332-1-2 | Yes |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No | Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No | Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | No | Low smoke according to EN IEC 61034-2 | No |
| Halogen-free according to EN IEC 60754-1 | No | Halogen-free according to EN IEC 60754-2 | No |
| Halogen-free according to EN IEC 60754-3 | No | Fire behavior according to EN 13501-6: Class | Eca |
| Fire behavior according to EN 13501-6: Smoke development | without | Fire behavior according to EN 13501-6: Droplet behavior | without |
| Fire behavior according to EN 13501-6: Acid development | without | Oil-resistant according to EN IEC 60811-404 | No |
| Cold-resistant according to EN 60811-504+505+506 | No | Outer diameter approx. | 11.3 mm |
| Min. permissible bending radius, flexible use/free movement | 226 mm | Min. permissible bending radius, stationary use/fixed installation | 67.8 mm |
| Permissible cable outer temperature during assembly/handling | -15..70 °C | Permissible cable outer temperature after installation without vibration | -40..80 °C |
| Rated voltage U0 | 300 V | Rated voltage U | 500 V |