Frequency Inverter ATV320, 2.2kW, 380-500V, 3-phase, Compact – ATV320U22N4C
€ 722,28 exkl. USt.
Frequency Inverter ATV320, 2.2kW, 380-500V, 3-phase, Compact – ATV320U22N4C is backordered and will ship as soon as it is back in stock.
ATV320 compact frequency inverter. Dimensions 140 x 228 x 158 (with EMC plate) mm, power 2.2 kW. Supply voltage 3-phase 380-500 V 50/60 Hz, with integrated EMC filter. Rated supply voltage, min. U1, max. U2 200 (U1)-240 V (U2), 380 (U1)-500 V (U2). Inverters are supplied with an integrated Category C2 EMC filter. The filter can be switched off. Inverters are supplied with an EMC plate for customer-side mounting. Description Integrated safety technology with 5 functions: Safe Torque Off (STO), Safe Stop 1 (SS1), Safe Limited Speed (SLS), Guard Door Locking (GDL), Safe Maximum Speed (SMS). Operation of asynchronous and synchronous motors in open loop. SVC control (sensorless vector control) provides highest speed quality and stability U/F control, U/F2 control, energy saving function. Max. frequency 599 Hz. Easiest commissioning, intuitive operation and Plug & Drive, pre-set for the most common applications. Options for loading, editing, saving inverter configurations with tools such as SoMove commissioning software, decentralized terminals and configuration tools -Simple-Loader- and -Multi-Loader-. Integrated, deactivatable Class A radio interference filter. For operation on IT networks. 6 logic inputs with multiple assignable functions, 3 analog inputs, 2 of which can be switched as digital inputs. Integrated braking module enables 4-quadrant operation without retrofitting.
€ 722,28 exkl. USt.
Frequency Inverter ATV320, 2.2kW, 380-500V, 3-phase, Compact – ATV320U22N4C is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Rated output current I2N | 5.5 A | Max. output power at square load at rated output voltage | 2.2 kW |
| Supports protocol for MODBUS | Yes | Supports protocol for PROFINET CBA | No |
| Supports protocol for AS-Interface Safety at Work | No | Number of HW interfaces other | 1 |
| Brake chopper integrated | No | 4-quadrant operation possible | Yes |
| Depth | 158 mm | Max. output frequency | 599 Hz |
| Max. output power at linear load at rated output voltage | 2.2 kW | Relative symmetrical mains voltage tolerance | 10 % |
| Number of analogue outputs | 1 | Supports protocol for SUCONET | No |
| Supports protocol for SafetyBUS p | No | Supports protocol for other bus systems | Yes |
| Number of HW interfaces parallel | 0 | Output phase number | 3 |
| Relative symmetrical mains frequency tolerance | 5 % | Supports protocol for CAN | Yes |
| Supports protocol for BACnet | No | Number of HW interfaces USB | 0 |
| Number of digital inputs | 6 | Supports protocol for INTERBUS | No |
| Supports protocol for PROFIsafe | No | Type of converter | U-converter |
| Supports protocol for TCP/IP | No | Supports protocol for PROFIBUS | Yes |
| With optical interface | No | Supports protocol for ASI | No |
| Supports protocol for PROFINET IO | Yes | Number of HW interfaces serial TTY | 0 |
| Supports protocol for KNX | No | Supports protocol for Data-Highway | No |
| Supports protocol for DeviceNet | Yes | Mains voltage | 380..500 V |
| Number of analogue inputs | 3 | Supports protocol for SERCOS | No |
| Supports protocol for EtherNet/IP | Yes | With PC connection | Yes |
| Supports protocol for LON | No | Number of HW interfaces serial RS-232 | 0 |
| Degree of protection (IP) | IP20 | Mains frequency | 50/60 Hz |
| Input phase number | 3 | With operating element | Yes |
| Use in industrial area permitted | Yes | Use in residential and commercial area permitted | No |
| Number of HW interfaces Industrial Ethernet | 1 | Number of HW interfaces serial RS-422 | 0 |
| Degree of protection (NEMA) | 1 | Height | 184 mm |
| Max. output voltage | 500 V | Supports protocol for Foundation Fieldbus | No |
| Number of interfaces PROFINET | 0 | Number of HW interfaces serial RS-485 | 1 |
| Width | 140 mm | Number of digital outputs | 1 |
| Supports protocol for DeviceNet Safety | No | Supports protocol for INTERBUS-Safety | No |