MS! Frequency inverter ATV320, 0.75kW, 200-240V, 1-phase, Compact – ATV320U07M2C
€ 355,98 exkl. USt.
MS! Frequency inverter ATV320, 0.75kW, 200-240V, 1-phase, Compact – ATV320U07M2C is backordered and will ship as soon as it is back in stock.
Frequency inverter ATV320, compact. Dimensions 72 x 143 x 138 mm, power KW 0.75 kW. Supply voltage 1-phase 200-240 V 50/60 Hz, with integrated EMC filter. Rated supply voltage, min. U1, max. U2 200 (U1-240 V (U2), 380 (U1-500 V (U2). Inverters are supplied with integrated category C2 EMC filter. The filter can be switched off. Inverters are supplied with an EMC plate for customer installation. Description Integrated safety technology with 5 functions safely disconnected torque (STO), safe stop 1 (SS1), safely reduced speed (SLS), safe guard door interlock (GDL), safe maximum speed (SMS). Operation of asynchronous and synchronous motors in open loop. SVC control (sensorless vector control) provides highest speed quality and stability U/F control, U/F2 control, energy saving function. Max. frequency 599 Hz. Simplest commissioning, intuitive operation as well as Plug & Drive, pre-set for the most common applications. Options for loading, editing, saving the inverter configurations with tools such as the SoMove commissioning software, the decentralized terminals and the configuration tools -Simple-Loader- and -Multi-Loader-. Class A radio interference filter integrated, deactivatable. For operation on IT networks. 6 logic inputs assignable with multiple functions, 3 analog inputs, 2 of which can be switched as digital inputs. Integrated braking module enables 4-quadrant operation without retrofitting.
€ 355,98 exkl. USt.
MS! Frequency inverter ATV320, 0.75kW, 200-240V, 1-phase, Compact – ATV320U07M2C is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Supports protocol for INTERBUS-Safety | No | 4-quadrant operation possible | Yes |
| Number of other HW interfaces | 1 | Supports protocol for BACnet | No |
| Supports protocol for SUCONET | No | Depth | 138 mm |
| Number of serial HW interfaces RS-232 | 0 | Number of industrial Ethernet HW interfaces | 1 |
| Supports protocol for DeviceNet Safety | No | Supports protocol for Foundation Fieldbus | No |
| Number of parallel HW interfaces | 0 | Supports protocol for MODBUS | Yes |
| Supports protocol for PROFIBUS | Yes | Permitted for use in industrial sector | Yes |
| Number of analogue inputs | 3 | Number of analogue outputs | 1 |
| Height | 143 mm | Type of converter | Voltage source converter |
| Supports protocol for PROFINET IO | Yes | Supports protocol for CAN | Yes |
| With control element | Yes | Relative symmetrical mains frequency tolerance | 5 % |
| Degree of protection (IP) | IP20 | Supports protocol for DeviceNet | Yes |
| Supports protocol for INTERBUS | No | With optical interface | No |
| Number of serial HW interfaces RS-485 | 1 | Supports protocol for Data-Highway | No |
| Supports protocol for ASI | No | Permitted for use in residential and commercial areas | No |
| Rated output current I2N | 4.8 A | Max. output voltage | 240 V |
| Max. output frequency | 599 Hz | Output phase number | 3 |
| Width | 72 mm | Degree of protection (NEMA) | 1 |
| With PC connection | Yes | Number of serial HW interfaces RS-422 | 0 |
| Number of PROFINET interfaces | 0 | Supports protocol for KNX | No |
| Max. output power at quadratic load at rated output voltage | 0.75 kW | Number of USB HW interfaces | 0 |
| Max. output power at linear load at rated output voltage | 0.75 kW | Mains frequency | 50/60 Hz |
| Number of serial HW interfaces TTY | 0 | Supports protocol for PROFIsafe | No |
| Supports protocol for EtherNet/IP | Yes | Supports protocol for SERCOS | No |
| Supports protocol for LON | No | Supports protocol for TCP/IP | No |
| Number of digital inputs | 6 | Number of digital outputs | 1 |
| Relative symmetrical mains voltage tolerance | 10 % | Mains voltage | 200..240 V |
| Brake chopper integrated | No | Supports protocol for other bus systems | Yes |
| Supports protocol for SafetyBUS p | No | Supports protocol for AS-Interface Safety at Work | No |
| Supports protocol for PROFINET CBA | No | Input phase number | 1 |