Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Technische Parameter
Technische Parameter
| Weight | 51 kg/km | Outer diameter approx. | 7 mm |
| Characteristic impedance | 75 Ohm | Number of sheath layers | 1 |
| Inner conductor class | Class 1 = solid | Max. tensile strength during installation | 0.15 kN |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No | Outer conductor material | Copper |
| 2-core coaxial cable (twinax) | No | Halogen-free according to EN IEC 60754-2 | No |
| Dielectric | Polyethylene, foamed (Foam PE) | Halogen-free according to EN IEC 60754-3 | No |
| Permissible external cable temperature after installation without vibration | -40..70 °C | Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Sheath material | other | Paired coaxial cable | No |
| Permissible external cable temperature during assembly/handling | -25..55 °C | Min. permissible bending radius, stationary use/fixed installation | 35 mm |
| Fire behaviour according to EN 13501-6: Smoke emission | s1a | Suitable for laying in the ground | No |
| Fire behaviour according to EN 13501-6: Class | Cca | Low smoke according to EN IEC 61034-2 | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | Yes | Number of shield layers | 3 |
| Outer conductor surface | tinned | Outer conductor diameter | 6.9 mm |
| Min. permissible bending radius, flexible use/free movement | 45 mm | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Outer conductor shape | foil + braid | Inner conductor surface | bare |
| Min. permissible bending radius, flexible use with forced guidance | 70 mm | Fire behaviour according to EN 13501-6: Droplet formation | d1 |
| Inner conductor material | Copper | Permissible type of installation in the ground | exposed and installation pipe for underground installation |
| Fire behaviour according to EN 13501-6: Acid development | a1 | Halogen-free according to EN IEC 60754-1 | No |
| Reinforcement material | other | Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-1-2 | No | Sheath material specification | other |
| Reinforcement/Armouring | none | Inner conductor diameter | 1.1 mm |
| Functional integrity according to IEC 60331-23 | No | Sheath colour | black |