ÖLFLEX CLASSIC 110 3X1,5 cut length
€ 1,47 exkl. USt.
ÖLFLEX CLASSIC 110 3X1,5 cut length is backordered and will ship as soon as it is back in stock.
Fixed installation as well as occasional flexible use without tensile stress with free, non-continuously recurring movement, Dry or damp rooms, with normal mechanical stress, Suitable for torsion applications typical in the loop of wind turbines (WTG), In power chains for travel distances up to 5 m and 0.2 ... 1 million bending cycles, for the following dimensions: 0.5 to 2.5 mm² and 2 to 7 cores, Wide range of standardized lengths and individual cuts, Very large product spectrum, Designs with up to 100 cores, Fine-wire strand of bare copper wires, PVC core insulation LAPP P8/1, Cores twisted in layers, Sheath: PVC, grey (similar to RAL 7001), VDE Reg.-No. 7030 for the following dimensions: up to 2.5 mm²: 2 - 65 cores from 4 mm²: 2 - 7 cores from 25 mm²: 2 - 5 cores, Flame-retardant according to IEC 60332-1-2, Good chemical resistance, Oil-resistant according to DIN EN 50290-2-22 (TM54),
€ 1,47 exkl. USt.
ÖLFLEX CLASSIC 110 3X1,5 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Conductor material | Copper | Conductor surface | bare |
| Nominal cross-section of conductor | 1.5 mm² | Conductor class | Class 5 = fine-stranded |
| Number of cores | 3 | Screen over stranding element | none |
| Stranding element | no | Screen over stranding | none |
| Core insulation material | Polyvinyl chloride (PVC) | Core insulation specification | other |
| Core identification | Numbers | With protective conductor | No |
| Supporting element | none | Sheath material | Polyvinyl chloride (PVC) |
| Sheath material specification | other | Sheath colour | grey |
| Screen | No | Cable geometry | round |
| Torsion protection | No | Flame-retardant according to IEC 60332-1-2 | Yes |
| Flame-retardant according to IEC 60332-3-21 (Cat A F/R) | No | Flame-retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame-retardant according to IEC 60332-3-23 (Cat B) | No | Flame-retardant according to IEC 60332-3-24 (Cat C) | No |
| Flame-retardant according to IEC 60332-3-25 (Cat D) | No | Low smoke according to EN IEC 61034-2 | No |
| Halogen-free according to EN IEC 60754-1 | No | Halogen-free according to EN IEC 60754-2 | No |
| Halogen-free according to EN IEC 60754-3 | No | Fire behaviour according to EN 13501-6: Class | Eca |
| Fire behaviour according to EN 13501-6: Smoke development | none | Fire behaviour according to EN 13501-6: Droplet formation | none |
| Fire behaviour according to EN 13501-6: Acid development | none | Oil-resistant according to EN IEC 60811-404 | No |
| Cold-resistant according to EN 60811-504+505+506 | Yes | Outer diameter approx. | 6.7 mm |
| Min. permissible bending radius, flexible use with forced guidance | 100.5 mm | Min. permissible bending radius, flexible use/free movement | 67 mm |
| Min. permissible bending radius, static use/fixed installation | 26.8 mm | Permissible external cable temperature during installation/handling | -5..70 °C |
| Permissible external cable temperature after installation without vibration | -40..80 °C | Nominal voltage U0 | 300 V |
| Nominal voltage U | 500 V |