TeSys U basic units. Basic unit, TeSys U, 32A, without terminals. Rated power 0.1-15 kW, direction of rotation 1, MTZ 13, control voltage . Universal basic units with pre-wired switching and protective combination, standard up to 12 / 32 A and with 2 auxiliary contacts (1 NO + 1 NC). Installation width up to 15 kW only 45 mm (direct and reversing starters), full coordination according to IEC 947-6-2 (weld-free). TeSys U is a complete motor starter that includes the functions of a motor protection circuit breaker and contactor. With only two basic units, the power range of 0.1-15 kW can be covered. The highlight: The control voltage and current range only need to be determined at the last second by a plug-in control unit.
€ 85,53 exkl. USt.
Power Base, TeSys U, 32A, Screw Terminals – LUB32 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Type of motor starter | Direct starter (DOL) | With short-circuit release | Yes |
| Rated control supply voltage AC 50 Hz | 24..240 V | Rated control supply voltage AC 60 Hz | 24..240 V |
| Rated control supply voltage DC | 24..220 V | Voltage type for actuation | AC/DC |
| Rated operating power at AC-3, 230 V, 3-phase | 7.5 kW | Rated operating power at AC-3, 400 V | 15 kW |
| Rated power, 460 V, 60 Hz, 3-phase | 15 kW | Rated power, 575 V, 60 Hz, 3-phase | 15 kW |
| Rated operational current Ie | 32 A | Rated operational current at AC-3, 400 V | 32 A |
| Conditional rated short-circuit current, coordination type 1, 480 Y/277 V | 10000 A | Conditional rated short-circuit current, coordination type 1, 600 Y/347 V | 4000 A |
| Conditional rated short-circuit current, coordination type 2, 230 V | 50000 A | Conditional rated short-circuit current, coordination type 2, 400 V | 50000 A |
| Number of auxiliary contacts as normally open | 1 | Number of auxiliary contacts as normally closed | 1 |
| Ambient temperature, upper limit without restrictions | 70 °C | Type of main current circuit connection | Screw connection |
| Design of electrical connection for auxiliary and control circuit | Screw connection | Suitable for DIN rail mounting | Yes |
| With transformer | No | Number of command points | 3 |
| Suitable for EMERGENCY STOP | No | Coordination type according to IEC 60947-4-3 | Class 2 |
| Number of indicator lights | 0 | External reset possible | No |
| With fuse | No | Degree of protection (IP) | IP20 |
| Supports protocol for TCP/IP | No | Supports protocol for PROFIBUS | No |
| Supports protocol for CAN | No | Supports protocol for INTERBUS | No |
| Supports protocol for ASI | No | Supports protocol for MODBUS | No |
| Supports protocol for Data-Highway | No | Supports protocol for DeviceNet | No |
| Supports protocol for SUCONET | No | Supports protocol for LON | No |
| Supports protocol for PROFINET IO | No | Supports protocol for PROFINET CBA | No |
| Supports protocol for SERCOS | No | Supports protocol for Foundation Fieldbus | No |
| Supports protocol for EtherNet/IP | No | Supports protocol for AS-Interface Safety at Work | No |
| Supports protocol for DeviceNet Safety | No | Supports protocol for INTERBUS-Safety | No |
| Supports protocol for PROFIsafe | No | Supports protocol for SafetyBUS p | No |
| Supports protocol for other bus systems | No | Width | 45 mm |
| Height | 154 mm | Depth | 126 mm |