Control unit, TeSys U, 12A, with screw terminals – LUB12
€ 58,86 exkl. USt.
Control unit, TeSys U, 12A, with screw terminals – LUB12 is backordered and will ship as soon as it is back in stock.
TeSys U basic units. Basic unit, TeSys U, 12A, without terminals. Rated power 0.1-5.5 kW, 1 direction of rotation, MTZ 13, control voltage -. Universal basic units with pre-wired switching and protection combination, standard up to 12 / 32 A and with 2 auxiliary contacts (1 NO + 1 NC). Width up to 15 kW only 45 mm (direct and reversing starters), complete coordination according to IEC 947-6-2 (weld-free). TeSys U is a complete motor starter that combines the functions of motor circuit breaker and contactor. With only two basic units, the power range of 0.1-15 kW is covered. The highlight: The control voltage and current range only need to be determined at the last second by a plug-in control unit.
€ 58,86 exkl. USt.
Control unit, TeSys U, 12A, with screw terminals – LUB12 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Type of motor starter | Direct-on-line starter (DOL) | With short-circuit release | Yes |
| Rated control supply voltage AC 50 Hz | 24..240 V | Rated control supply voltage AC 60 Hz | 24..240 V |
| Rated control supply voltage DC | 24..220 V | Voltage type for actuation | AC/DC |
| Rated operational power at AC-3, 230 V, 3-phase | 3 kW | Rated operational power at AC-3, 400 V | 5.5 kW |
| Rated power, 460 V, 60 Hz, 3-phase | 5.5 kW | Rated power, 575 V, 60 Hz, 3-phase | 5.5 kW |
| Rated operational current Ie | 12 A | Rated operational current at AC-3, 400 V | 12 A |
| Conditional rated short-circuit current, coordination type 1, 480 Y/277 V | 10000 A | Conditional rated short-circuit current, coordination type 1, 600 Y/347 V | 4000 A |
| Conditional rated short-circuit current, coordination type 2, 230 V | 50000 A | Conditional rated short-circuit current, coordination type 2, 400 V | 50000 A |
| Number of auxiliary contacts as normally open | 1 | Number of auxiliary contacts as normally closed | 1 |
| Ambient temperature, upper limit without restrictions | 70 °C | Connection type main current circuit | Screw connection |
| Type of electrical connection for auxiliary and control circuit | Screw connection | Suitable for DIN rail mounting | Yes |
| With transformer | No | Number of command points | 3 |
| Suitable for EMERGENCY STOP | No | Coordination type according to IEC 60947-4-3 | Class 2 |
| Number of indicator lights | 0 | External reset possible | No |
| With fuse | No | Degree of protection (IP) | IP20 |
| Supports protocol for TCP/IP | No | Supports protocol for PROFIBUS | No |
| Supports protocol for CAN | No | Supports protocol for INTERBUS | No |
| Supports protocol for ASI | No | Supports protocol for MODBUS | No |
| Supports protocol for Data-Highway | No | Supports protocol for DeviceNet | No |
| Supports protocol for SUCONET | No | Supports protocol for LON | No |
| Supports protocol for PROFINET IO | No | Supports protocol for PROFINET CBA | No |
| Supports protocol for SERCOS | No | Supports protocol for Foundation Fieldbus | No |
| Supports protocol for EtherNet/IP | No | Supports protocol for AS-Interface Safety at Work | No |
| Supports protocol for DeviceNet Safety | No | Supports protocol for INTERBUS-Safety | No |
| Supports protocol for PROFIsafe | No | Supports protocol for SafetyBUS p | No |
| Supports protocol for other bus systems | No | Width | 45 mm |
| Height | 154 mm | Depth | 126 mm |