Circuit breaker, S00, for motor protection, Class 10, A-release 4.5-6.3A, N-release 82A – 3RV10111GA10
€ 73,12 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 4.5-6.3A, N-release 82A – 3RV10111GA10 is backordered and will ship as soon as it is back in stock.
Circuit breaker size S00 for motor protection, CLASS 10 A release 4.5...6.3 A N release 82 A screw terminal Standard switching capacity SIRIUS 3RV1 circuit breaker for motor protection for safe shutdown in the event of a short circuit and protection of loads and the plant against overload, as well as for safe isolation of the plant from the mains. The compact and climate-proof circuit breakers are optimized for use in load feeders due to their low heat dissipation, and are also suitable for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection, as main and EMERGENCY STOP switches, and for use in IT systems. They are available with screw terminals and optionally with an integrated auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary releases, etc., are standardized for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 73,12 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 4.5-6.3A, N-release 82A – 3RV10111GA10 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Overload release current setting | 4.5..6.3 A | Setting range of the instantaneous short-circuit release | 82..82 A |
| With thermal overload protection | Yes | Phase failure sensitive | Yes |
| Release technology | magnetic | Rated operational voltage | 690..690 V |
| Rated continuous current Iu | 6.3 A | Rated operational power at AC-3, 230 V | 1.5 kW |
| Rated operational power at AC-3, 400 V | 2.2 kW | Type of electrical connection of main circuit | Screw connection |
| Type of actuating element | Toggle lever | Device construction | Built-in device fixed-mounted technical |
| With integrated auxiliary switch | No | With integrated undervoltage release | No |
| Number of poles | 3 | Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA |
| Degree of protection (IP) | IP20 | Height | 90 mm |
| Width | 45 mm | Depth | 75 mm |