Circuit breaker, S00, motor protection, Class 10, A-release 7-10A, N-release 130A - 3RV20111JA25
€ 91,93 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-release 7-10A, N-release 130A - 3RV20111JA25 is backordered and will ship as soon as it is back in stock.
Circuit breaker Size S00 for motor protection, CLASS 10 A-release 7...10 A N-release 130 A spring-type terminal Standard switching capacity with transverse auxiliary switch 1S+1Ö Circuit breakers SIRIUS 3RV2 for motor protection for safe shutdown in the event of a short circuit and protection of consumers and systems against overload, as well as for safe disconnection of the system from the network. The compact and climate-proof circuit breakers are optimized for use in consumer feeders due to their low heat dissipation, naturally also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with built-in auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches, etc., is uniform for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 91,93 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-release 7-10A, N-release 130A - 3RV20111JA25 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Overload release current setting | 7..10 A | Type of electrical connection of main circuit | Spring-loaded terminal |
| With integrated auxiliary switch | Yes | Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA |
| Adjustment range of delayed short-circuit release | 130..130 A | Rated operational power at AC-3, 400 V | 4 kW |
| With thermal overload protection | Yes | Rated operational voltage | 690..690 V |
| Phase-failure sensitive | Yes | Number of poles | 3 |
| Width | 45 mm | Release system | magnetic |
| Type of control element | other | Device construction | Built-in device fixed-mounted technical |
| Degree of protection (IP) | IP20 | Height | 106 mm |
| With integrated undervoltage release | No | Depth | 97 mm |
| Rated operational power at AC-3, 230 V | 2.2 kW | Power loss | 9.25 W |
| Rated permanent current Iu | 10 A |