Circuit breaker, S00, motor protection, Class 10, A-release 1.4-2A, N-release 26A – 3RV20111BA15
€ 83,57 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-release 1.4-2A, N-release 26A – 3RV20111BA15 is backordered and will ship as soon as it is back in stock.
Circuit breaker Size S00 for motor protection, CLASS 10 A release 1.4...2 A N release 26 A screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC Circuit breaker SIRIUS 3RV2 for motor protection for safe shutdown in the event of a short circuit and protection of consumers and systems from overload, as well as for safe disconnection of the system from the mains. The compact and climate-proof circuit breakers are optimized for use in load feeders due to their low heat dissipation, naturally also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), system protection, short-circuit protection for starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with an integrated auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary releases, signaling switches, etc., are standardized for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 83,57 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-release 1.4-2A, N-release 26A – 3RV20111BA15 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Power loss | 7.25 W | Rated permanent current Iu | 2 A |
| Rated operating power at AC-3, 400 V | 0.75 kW | Device construction type | Built-in device, fixed installation |
| With thermal overload protection | Yes | Type of electrical connection of main circuit | Screw connection |
| With integrated auxiliary switch | Yes | Width | 45 mm |
| Depth | 97 mm | Type of control element | Other |
| Height | 97 mm | Release technique | Magnetic |
| Number of poles | 3 | Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA |
| Overload release current setting | 1.4..2 A | Phase failure sensitive | Yes |
| Degree of protection (IP) | IP20 | Setting range of the undelayed short-circuit release | 26..26 A |
| Rated operating voltage | 690..690 V | Rated operating power at AC-3, 230 V | 0.4 kW |
| With integrated undervoltage release | No |