Circuit breaker size S00 for motor protection, CLASS 10 A release 0.9...1.25 A N-release 16 A spring-type terminal standard switching capacity with transverse auxiliary switch 1NO+1NC Circuit breaker SIRIUS 3RV2 for motor protection for safe shutdown in the event of a short circuit and protection of consumers and systems from overload, as well as for safe disconnection of the system from the mains. The compact and climate-proof circuit breakers are optimized for use in load feeders due to their low heat dissipation, naturally also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-type terminals for a fast, maintenance-free and vibration-proof connection, and optionally with integrated auxiliary switch. The extensive accessories, such as auxiliary switches, auxiliary releases, signaling switches, etc., are uniform for all sizes. The use of various power supply options, such as the associated infeed system SIRIUS 3RV29, significantly reduces the main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 80,78 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-release 0.9-1.25A, N-release 16A – 3RV20110KA25 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Rated permanent current Iu | 1.25 A | Degree of protection (IP) | IP20 |
| Height | 106 mm | Power loss | 7.25 W |
| Phase-failure sensitive | Yes | Release technology | Magnetic |
| With integrated undervoltage release | No | Overload release current setting | 0.9..1.25 A |
| Actuating element design | Other | Setting range of the instantaneous short-circuit release | 16..16 A |
| Rated operational power at AC-3, 230 V | 0.2 kW | With integrated auxiliary switch | Yes |
| Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA | Number of poles | 3 |
| Rated operational voltage | 690..690 V | Rated operational power at AC-3, 400 V | 0.37 kW |
| Main circuit connection type | Spring-type terminal | Device construction type | Built-in device fixed installation technology |
| With thermal overload protection | Yes | Width | 45 mm |