Circuit breaker, S00, for motor protection, Class 10, A-release 0.9-1.25A, N-release 16A – 3RV20110KA15
€ 80,78 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 0.9-1.25A, N-release 16A – 3RV20110KA15 is backordered and will ship as soon as it is back in stock.
Circuit breaker size S00 for motor protection, CLASS 10 A release 0.9...1.25 A N release 16 A screw connection standard switching capacity with transverse auxiliary switch 1 NO + 1 NC. SIRIUS 3RV2 circuit breakers for motor protection for safe shutdown in the event of a short circuit and protection of loads and systems from overload, as well as for safe disconnection of the system from the mains. The compact and climate-proof circuit breakers are optimized for use in load feeders due to their low heat dissipation, of course also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY-STOP switches and for use in IT networks. They are available with screw or spring-type terminals for quick, maintenance-free and vibration-proof connection, and optionally with an integrated auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary releases, signal switches, etc., are uniform for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up to date - the SIRIUS modular system.
€ 80,78 exkl. USt.
Circuit breaker, S00, for motor protection, Class 10, A-release 0.9-1.25A, N-release 16A – 3RV20110KA15 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| With thermal overload protection | Yes | Rated operational power at AC-3, 400 V | 0.37 kW |
| Height | 97 mm | Phase failure sensitive | Yes |
| Depth | 97 mm | Overload release current setting | 0.9..1.25 A |
| Rated continuous current Iu | 1.25 A | Rated operational power at AC-3, 230 V | 0.2 kW |
| Type of electrical connection of main circuit | Screw connection | Device construction type | Built-in device fixed-mounted technology |
| With integrated undervoltage release | No | Width | 45 mm |
| Power loss | 7.25 W | Type of operating element | Other |
| Setting range of the instantaneous short-circuit release | 16..16 A | Release technology | Magnetic |
| Number of poles | 3 | With integrated auxiliary switch | Yes |
| Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA | Degree of protection (IP) | IP20 |
| Rated operational voltage | 690..690 V |