Circuit breaker, S00, motor protection, Class 10, A-trip 0.11-0.16A, N-trip 2.1A – 3RV20110AA10
€ 56,83 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-trip 0.11-0.16A, N-trip 2.1A – 3RV20110AA10 is backordered and will ship as soon as it is back in stock.
Circuit breaker size S00 for motor protection, CLASS 10 A release 0.11...0.16 A N release 2.1 A screw connection standard switching capacity SIRIUS 3RV2 circuit breakers for motor protection for safe short-circuit shutdown and protection of consumers and systems from overload, as well as for safe disconnection of the system from the mains. The compact and climate-proof circuit breakers are optimized for use in consumer feeders due to their low heat dissipation, and of course also for IE3/IE4 motors. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY STOP switches and for use in IT networks. They are available with screw or spring-loaded terminals for a fast, maintenance-free and vibration-proof connection, and optionally with integrated auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary releases, signaling switches, etc., are uniform for all sizes. The use of various power supply options, such as the associated SIRIUS 3RV29 infeed system, significantly reduces main circuit wiring. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.
€ 56,83 exkl. USt.
Circuit breaker, S00, motor protection, Class 10, A-trip 0.11-0.16A, N-trip 2.1A – 3RV20110AA10 is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Degree of protection (IP) | IP20 | Type of control element | other |
| Rated operational power at AC-3, 400 V | 0.04 kW | Width | 45 mm |
| Rated operational power at AC-3, 230 V | 0 kW | Phase failure sensitive | Yes |
| With integrated auxiliary switch | No | With integrated undervoltage release | No |
| Rated operational voltage | 690..690 V | Setting range of the instantaneous short-circuit release | 2.1..2.1 A |
| With thermal overload protection | Yes | Device construction type | Built-in device fixed-mounted technology |
| Number of poles | 3 | Rated ultimate short-circuit breaking current Icu at 400 V, AC | 100 kA |
| Height | 97 mm | Release technology | magnetic |
| Rated permanent current Iu | 0.16 A | Power loss | 5.5 W |
| Connection type main current circuit | Screw connection | Overload release current setting | 0.11..0.16 A |
| Depth | 97 mm |