ÖLFLEX CLASSIC 110 3G1.5 cut length
€ 1,40 exkl. USt.
ÖLFLEX CLASSIC 110 3G1.5 cut length is backordered and will ship as soon as it is back in stock.
For fixed installation as well as occasional flexible use without tensile stress during free, not continuously recurring movement, dry or damp rooms, with normal mechanical stress, suitable for torsional applications typical for the loop in wind turbines (WTG), in power chains for travel up to 5 m and 0.2 ... 1 million bending cycles, for the following dimensions: 0.5 to 2.5 mm² and 2 to 7 cores, large selection of standardized lengths and individual cuts, very large range of articles, versions with up to 100 cores, fine-stranded wire made of bare copper wires, PVC core insulation LAPP P8/1, cores twisted in layers, sheath: PVC, grey (similar to RAL 7001), VDE Reg. No. 7030 for the following dimensions: up to 2.5 mm²: 2 - 65 cores from 4 mm²: 2 - 7 cores from 25 mm²: 2 - 5 cores, flame retardant according to IEC 60332-1-2, good chemical resistance, oil resistant according to DIN EN 50290-2-22 (TM54),
€ 1,40 exkl. USt.
ÖLFLEX CLASSIC 110 3G1.5 cut length is backordered and will ship as soon as it is back in stock.
Technische Parameter
Technische Parameter
| Shield over stranding | without | Flame-retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Conductor material | Copper | Jacket material specification | Other |
| Torsion protection | No | Fire behaviour according to EN 13501-6: Acid development | None |
| Core identification | Numbers | Cable geometry | Round |
| Stranding element | No | Halogen-free according to EN IEC 60754-2 | No |
| Halogen-free according to EN IEC 60754-3 | No | Min. permissible bending radius, flexible use with forced guidance | 100.5 mm |
| Min. permissible bending radius, flexible use/free movement | 67 mm | Shield over stranding element | None |
| Flame-retardant according to IEC 60332-3-22 (Cat A) | No | Low smoke according to EN IEC 61034-2 | No |
| Fire behaviour according to EN 13501-6: Class | Eca | Permissible cable outer temperature during assembly/handling | -15..70 °C |
| Rated voltage U | 500 V | Cold-resistant according to EN 60811-504+505+506 | No |
| Outer diameter approx. | 6.7 mm | Min. permissible bending radius, stationary use/fixed installation | 26.8 mm |
| Conductor shape | Round | Support element | None |
| Flame-retardant according to IEC 60332-3-23 (Cat B) | No | Number of cores | 3 |
| Screen | No | Fire behaviour according to EN 13501-6: Droplet behaviour | None |
| Weight | 84 kg/km | With protective conductor | Yes |
| Sheath colour | Grey | Flame-retardant according to IEC 60332-3-25 (Cat D) | No |
| Oil-resistant according to EN IEC 60811-404 | No | Permissible cable outer temperature after installation without vibration | -40..80 °C |
| Conductor nominal cross-section | 1.5 mm² | Core insulation specification | Other |
| Sheath material | Polyvinyl chloride (PVC) | Flame-retardant according to IEC 60332-3-24 (Cat C) | No |
| Halogen-free according to EN IEC 60754-1 | No | Fire behaviour according to EN 13501-6: Smoke development | None |
| Conductor class | Class 5 = fine-stranded | Core insulation material | Polyvinyl chloride (PVC) |
| Flame-retardant according to IEC 60332-1-2 | Yes | Conductor surface | Bare |
| Rated voltage U0 | 300 V |