• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

VAILLANT  Art.Nr: 15472132161867

VAILLANT Vaillant Air/Water Heat Pump 7 kW AE aroTHERM Split plus VWL 75/8.2 AS 230V – 0010039758 DACH Version

Regular price
Regular price € 5.630,53 inkl. USt.
€ 4.692,11 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
DACH VersionGermany · Austria · SwitzerlandControl and documentation in German, mains connection 230 V / 50 Hz according to Central European standard – usable in all three countries.
5.07 kW
Heating output at A7/W35
5.2 COP
Coefficient of Performance at A7/W35
62 °C
Max. flow temperature
40 m
Max. line length
Please note: Outdoor unit, not a complete system. The VWL 75/8.2 AS is the split outdoor unit. For a ready-to-operate system, an indoor unit – hydraulic station or uniTOWER – as well as refrigerant lines and system control are required. We will gladly put together a suitable package upon request.

Advantages at a glance

COP 5.2 at A7/W35

5.07 kW heating output with only 0.98 kW consumption. Even at −7 °C, the unit still delivers 6.39 kW with a COP of 3.1.

🔧

Split instead of Monoblock

Only refrigerant lines run into the house, no water-carrying circuit to the outside. This eliminates the need for frost protection in the connecting line.

📏

Up to 40 m line length

Up to 30 m height difference if the outdoor unit is at the top, 10 m if it's at the bottom. This allows for great flexibility in placement.

🔊

Whisper-quiet operation

58 dB(A) maximum at A7/W35, only 48.7 dB(A) in 60% whisper mode at A-7/W35.

❄️

Active cooling

Integrated active cooling mode: 7.29 kW at A35/W18 with EER 4.0, in component cooling mode 7.0 kW at A35/W7.

🔌

230 V – no heavy-duty power required

Single-phase connection with a maximum of 14 A and 3.2 kW electrical power consumption.

Performance & Efficiency according to EN 14511

Operating point Output / Consumption / COP or EER
A7/W35 5.07 kW / 0.98 kW / 5.2
A2/W35 3.13 kW / 0.71 kW / 4.4
A−7/W35 6.39 kW / 2.06 kW / 3.1
A7/W45 4.78 kW / 1.23 kW / 3.9
A7/W55 6.45 kW / 2.08 kW / 3.1
Cooling A35/W18 7.29 kW / 1.82 kW / EER 4.0
Cooling A35/W7 7.00 kW / 2.69 kW / EER 2.6

Technical Data

Parameter Value
Type of construction Split outdoor unit (AS)
Refrigerant / pre-filled quantity / GWP R32 / 1.5 kg / 675
CO₂ equivalent 1.01 t
Electrical power consumption (max) 3.2 kW
Power supply / Current (max) 230 V (50 Hz) / 14 A
Protection class IP14B
Sound power level at A7/W35 (max) 58 dB(A)
Sound power level (ErP) 48.3 dB(A)
Sound power A−7/W35 in 60% whisper mode 48.7 dB(A)
Suction gas / liquid line connection 1/2″ / 1/4″
Dimensions (H × W × D) 960 × 1,100 × 450 mm
Weight ready for operation / gross 100 kg / 121 kg

Operating limits

Parameter Value
Heating temperature 5 – 62 °C
Storage temperature max. 55 °C, with auxiliary heating 70 °C
Distance between indoor and outdoor unit max. 40 m
Height difference, outdoor unit above max. 30 m
Height difference, outdoor unit below max. 10 m

Frequently asked questions

What does the DACH version mean?

The unit, control, and documentation are designed for the German-speaking region: menu navigation and documentation in German, mains connection 230 V / 50 Hz. This means the heat pump can be used equally in Germany, Austria, and Switzerland. Subsidies and registration requirements differ by country – your local installer will clarify this.

Split or monoblock – which is better?

With the split system, only refrigerant flows between the outdoor and indoor units, so nothing can freeze. However, this requires a refrigerant connection and thus a refrigeration certificate for commissioning. A monoblock like the aroTHERM plus is hydraulically simpler but must be connected frost-proof.

What refrigerant is used?

R32 with a GWP of 675 and 1.5 kg pre-fill, corresponding to 1.01 t CO₂ equivalent. If you prefer a natural refrigerant, the aroTHERM plus monoblock series offers units with R290 and a GWP of 0.02.

Does the 7 kW size fit my house?

The VWL 75/8.2 AS delivers 6.39 kW at −7 °C and 5.07 kW at 7 °C, each with a flow temperature of 35 °C. This is the typical size for a single-family house with a heating load of 6 to 8 kW. The exact sizing requires a heating load calculation according to EN 12831.

How far away can the outdoor unit be placed?

Up to 40 m of line length between the indoor and outdoor units. If the outdoor unit is higher, a height difference of up to 30 m is allowed; if it is lower, up to 10 m.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on sizing. For orders over €5,000, shipping within Austria is free.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download
Vorschau Scrollen im PDF möglich · Vollbild über das Öffnen-Symbol

Technische Parameter

Datenblatt0010039758.pdf