4.51 kW
Heating output at A7/W35
4.9 COP
Coefficient of Performance at A7/W35
62 °C
Max. flow temperature
40 m
Max. pipe length
Please note: Outdoor unit, not a complete system. The VWL 55/8.2 AS is the split outdoor unit. For an operational system, an indoor unit – hydraulic station or uniTOWER – as well as the refrigerant lines and system control are added. We assemble the appropriate package upon request.

Advantages at a glance

COP 4.9 at A7/W35

4.51 kW heating output with only 0.92 kW input. Even at -7 °C, the unit still delivers 4.89 kW with a COP of 3.0.

🔧

Split instead of monoblock

Only refrigerant lines lead into the house, no water-carrying circuit outside. This eliminates the need for frost protection in the connecting line.

📏

Up to 40 m pipe length

Up to 30 m height difference if the outdoor unit is at the top, 10 m if reversed. This provides a lot of freedom in placement.

🔊

Whisper mode

57 dB(A) maximum at A7/W35, in 60% whisper mode at A-7/W35 only 47.6 dB(A).

❄️

Active cooling

Integrated active cooling operation: 5.31 kW at A35/W18 with EER 4.2, in component cooling operation 5.22 kW at A35/W7.

🔌

230 V – no heavy-duty current required

Single-phase connection with a maximum of 12 A and 2.7 kW electrical power consumption.

Performance & Efficiency according to EN 14511

Operating point Output / Input / COP or EER
A7/W35 4.51 kW / 0.92 kW / 4.9
A2/W35 2.22 kW / 0.56 kW / 4.0
A−7/W35 4.89 kW / 1.63 kW / 3.0
A7/W45 4.13 kW / 1.15 kW / 3.6
A7/W55 5.36 kW / 1.91 kW / 2.8
Cooling A35/W18 5.31 kW / 1.26 kW / EER 4.2
Cooling A35/W7 5.22 kW / 1.74 kW / EER 3.0

Technical Data

Parameter Value
Type Split outdoor unit (AS)
Refrigerant / pre-filled quantity / GWP R32 / 1.3 kg / 675
CO₂ equivalent 0.88 t
Electrical power consumption (max) 2.7 kW
Voltage supply / Current (max) 230 V (50 Hz) / 12 A
Protection class IP14B
Sound power level at A7/W35 (max) 57 dB(A)
Sound power level (ErP) 47.5 dB(A)
Sound power A-7/W35 in 60% whisper mode 47.6 dB(A)
Connection suction gas / liquid line 1/2″ / 1/4″
Dimensions (H × W × D) 765 × 1,100 × 450 mm
Weight ready for operation / gross 86 kg / 107 kg

Operating limits

Parameter Value
Heating temperature 5 – 62 °C
Storage temperature max. 55 °C, with auxiliary heating 70 °C
Distance between indoor and outdoor unit max. 40 m
Height difference, outdoor unit above max. 30 m
Height difference, outdoor unit below max. 10 m

Frequently Asked Questions

What does the DACH version mean?

The device, control, and documentation are designed for the German-speaking region: menu navigation and documentation in German, mains connection 230 V / 50 Hz. This means the heat pump can be used equally in Germany, Austria, and Switzerland. Funding and registration requirements differ by country – your local installer will clarify this.

Split or monoblock – which is better?

In a split system, only refrigerant flows between the outdoor and indoor units, so nothing can freeze. However, it requires a refrigerant connection and thus a refrigeration certificate for commissioning. A monoblock like the aroTHERM plus is hydraulically simpler, but must be connected frost-proof.

Which refrigerant is used?

R32 with a GWP of 675 and 1.3 kg pre-fill, corresponding to 0.88 t CO₂ equivalent. If you prefer a natural refrigerant, the aroTHERM plus monoblock series offers devices with R290 and a GWP of 0.02.

Does the 5 kW size suit my house?

The VWL 55/8.2 AS delivers 4.89 kW at -7 °C and 4.51 kW at 7 °C, each at 35 °C flow. This is suitable for single-family homes with approximately 5 to 6 kW heating load. The exact dimensioning requires a heating load calculation according to EN 12831.

How far away can the outdoor unit be placed?

Up to 40 m pipe length between the indoor and outdoor units. If the outdoor unit is higher, a height difference of up to 30 m is allowed; if it is lower, up to 10 m.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and provide advice on sizing. Shipping within Austria is free for orders over €5,000.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download
Vorschau Scrollen im PDF möglich · Vollbild über das Öffnen-Symbol

Technische Parameter

Datenblatt0010039757.pdf