• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

VAILLANT  Art.Nr: 15473002152267

VAILLANT Vaillant Air/Water Heat Pump 7 kW aroTHERM plus VWL 75/8.1 Monobloc R290 – 8000033711 DACH Version

Regular price
Regular price € 7.646,19 inkl. USt.
€ 6.371,83 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
DACH VersionGermany · Austria · SwitzerlandControl and documentation in German, mains connection 230 V / 50 Hz according to Central European standard – can be used in all three countries.
6.94 kW
Heating output at A−7/W35
196 %
Efficiency ηs at 35 °C
R290
Natural refrigerant
75 °C
Max. flow temperature

Advantages at a glance

A+++ at 35 °C

196 % seasonal space heating energy efficiency. The /8.1 series is Vaillant's most efficient air-to-water heat pump.

🌱

Refrigerant R290

Propane with a GWP of 0.02 – virtually no global warming potential and long-term regulatory certainty.

🔊

Sound Safe System

Maximum sound power level of 57.4 dB(A), only 27.5 dB(A) at 3 m distance in night mode.

🌡️

Flow up to 75 °C

Renovation without radiator replacement: existing radiator systems can also continue to operate efficiently.

❄️

Active cooling

Activatable cooling mode with 6.66 kW at A35/W18 and EER 4.35. Structural preparation of the heating system required.

🔌

230 V – no heavy current required

Single-phase connection with a maximum of 15.5 A. The VR 940 for connection is included in the scope of delivery.

Performance & Efficiency according to EN 14511

Operating point Heating output / Input / COP
A7/W35 2.67 kW / 0.54 kW / 4.94
A2/W35 4.20 kW / 1.03 kW / 4.10
A−7/W35 6.94 kW / 2.36 kW / 2.94
A7/W45 2.66 kW / 0.75 kW / 3.54
A7/W55 3.75 kW / 1.33 kW / 2.82
A−7/W55 7.02 kW / 3.30 kW / 2.13
Cooling A35/W18 6.66 kW / 1.53 kW / EER 4.35

Technical data

Parameter Value
Energy efficiency class 35 °C / 55 °C A+++ / A++
Space heating efficiency ηs 35 °C / 55 °C 196 % / 142 %
Heating output partial load point A (Tj −7 °C) W35 5.9 kW
Refrigerant / Fill quantity / GWP R290 / 0.9 kg / 0.02
Electrical power consumption (max) 3.5 kW
Voltage supply / Current (max) 230 V (50 Hz) / 15.5 A
Protection class / Protection category IPX4 / I
Sound power level (max) 57.4 dB(A)
Sound power A7/W35 in whisper mode 46.2 dB(A)
Dimensions (H × W × D) 965 × 1,100 × 450 mm
Weight 130 kg
Heating connection flow and return G 1¼″
Heating circuit content 2.0 l

Application limits

Parameter Value
Flow temperature heating 20 – 75 °C
Distance outdoor unit to last indoor unit max. 20 m
Operating pressure heating circuit max. 2.5 bar
Installation Monoblock, outdoor installation
Color Black-grey RAL 7021

Scope of delivery

aroTHERM plus outdoor unit Condensate drain funnel Bag with small parts VR 940 communication module Documentation

Frequently Asked Questions

What does the DACH version mean?

The device, control system, and documentation are designed for the German-speaking market: menu navigation and documentation in German, mains connection 230 V / 50 Hz. This means the heat pump can be used in Germany, Austria, and Switzerland. Subsidies and registration requirements differ by country – your local installer will clarify this.

Why R290 and not R32 or R410A?

R290 is propane, a natural refrigerant with a global warming potential of 0.02 instead of several hundred. It is not subject to the shortage of fluorinated refrigerants and at the same time achieves higher flow temperatures – up to 75 °C here.

Does the 7 kW size fit my house?

The VWL 75/8.1 delivers 6.94 kW at -7 °C outside temperature and 35 °C flow. This is the typical size for a single-family house with a heating load of 7 to 9 kW, even partially renovated. The exact sizing is part of a heating load calculation according to EN 12831.

Can I continue to use old radiators with it?

Yes. With a flow of up to 75 °C, the aroTHERM plus reaches temperatures that can also serve older radiators. However, it only becomes efficient with a low flow – at 55 °C the efficiency is 142 %, at 35 °C it is 196 %.

How loud is the heat pump in operation?

57.4 dB(A) sound power at maximum, only 46.2 dB(A) in whisper mode at A7/W35. In night mode, it is 27.5 dB(A) at 3 m distance – quieter than a quiet living room.

What do I need in addition to the outdoor unit?

The aroTHERM plus is a monoblock; the complete refrigeration circuit is located outdoors. For a complete system, depending on the concept, a hydraulic station or a uniTOWER, a hot water storage tank, and the system control are added. We assemble the package as required.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on design. For orders over €5,000, shipping within Austria is free.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download