• Free shipping on orders over €5000 in AT

  • Consulting and Planning

  • Fast shipping

  • Current Daily Rates

VAILLANT  Art.Nr: 15473003102539

VAILLANT Vaillant Air/Water Heat Pump 10 kW aroTHERM plus VWL 105/8.1 Monoblock R290 – 8000033712 DACH Version

Regular price
Regular price € 10.095,53 inkl. USt.
€ 8.412,94 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.
DACH VersionGermany · Austria · SwitzerlandControl and documentation in German, mains connection 400 V / 50 Hz according to Central European standard – usable in all three countries.
10.58 kW
Heating output at A−7/W35
202 %
Efficiency ηs at 35 °C
R290
Natural refrigerant
75 °C
Max. flow temperature

Advantages at a glance

A+++ at 35 °C and at 55 °C

202 % space heating efficiency at 35 °C, 151 % at 55 °C – the highest rating in both temperature classes.

🌱

Refrigerant R290

Propane with a GWP of 0.02 – practically no global warming potential and long-term regulatory security.

🔊

Sound Safe System

Maximum sound power of 58.2 dB(A), only 27.5 dB(A) at 3m distance in night mode.

🌡️

Flow up to 75 °C

Renovation without radiator replacement: existing radiator systems can also be operated efficiently.

❄️

Active cooling

Activatable cooling operation with 11.66 kW at A35/W18 and EER 5.03. On-site preparation of the heating system required.

⚙️

Modulating inverter

The compressor dynamically adjusts the output to the heating load – from 5.69 kW at A7/W35 to 10.58 kW at -7 °C.

Performance & Efficiency according to EN 14511

Operating point Heating output / power input / COP
A7/W35 5.69 kW / 1.08 kW / 5.29
A2/W35 5.82 kW / 1.32 kW / 4.40
A−7/W35 10.58 kW / 3.52 kW / 3.01
A7/W45 6.08 kW / 1.51 kW / 4.03
A7/W55 5.57 kW / 1.75 kW / 3.19
A−7/W55 10.96 kW / 5.41 kW / 2.03
Cooling A35/W18 11.66 kW / 2.32 kW / EER 5.03

Technical data

Parameter Value
Energy efficiency class 35 °C / 55 °C A+++ / A+++
Space heating efficiency ηs 35 °C / 55 °C 202 % / 151 %
Heating capacity partial load point A (Tj −7 °C) W35 9.6 kW
Refrigerant / fill quantity / GWP R290 / 1.3 kg / 0.02
Electrical power consumption (max) 8.0 kW
Voltage supply / current (max) 400 V (50 Hz) / 14 A
Protection class / protection type IPX4 / I
Sound power level (max) 58.2 dB(A)
Sound power A7/W35 in whisper mode 49.6 dB(A)
Dimensions (H × W × D) 1,480 × 1,100 × 450 mm
Weight 206 kg
Heating flow and return connection G 1¼″
Heating circuit volume 4.5 l

Operating limits

Parameter Value
Flow temperature heating 20 – 75 °C
Distance outdoor unit to last indoor unit max. 20 m
Operating pressure heating circuit max. 2.5 bar
Installation Monoblock, outdoor installation
Color black-gray RAL 7021

Scope of delivery

aroTHERM plus outdoor unit Condensate drain funnel Bag with small parts VR 940 communication module Documentation

Frequently asked questions

What does the DACH version mean?

The device, controls, and documentation are designed for the German-speaking region: menu navigation and documentation in German, mains connection 400 V / 50 Hz. This allows the heat pump to be used equally in Germany, Austria, and Switzerland. Funding and registration requirements differ by country – your local installer will clarify this.

Why R290 and not R32 or R410A?

R290 is propane, a natural refrigerant with a global warming potential of 0.02 instead of several hundred. It is not affected by the scarcity of fluorinated refrigerants and at the same time achieves higher flow temperatures – up to 75 °C here.

Is the 10 kW size suitable for my house?

The VWL 105/8.1 delivers 10.58 kW at an outdoor temperature of -7 °C and a flow of 35 °C. This is suitable for larger single-family homes, two-family homes, or poorly insulated existing buildings with a heating load of around 9 to 12 kW. The exact design requires a heating load calculation according to EN 12831.

Why is this model A+++ even at 55 °C?

With 151% space heating efficiency at 55 °C, the 105/8.1 also achieves the highest rating in the high-temperature class. This makes it particularly interesting for renovations where the radiators remain.

How loud is the heat pump in operation?

58.2 dB(A) sound power at maximum, only 49.6 dB(A) in whisper mode at A7/W35. In night mode, it is 27.5 dB(A) at 3m distance – quieter than a quiet living room.

What else do I need besides the outdoor unit?

The aroTHERM plus is a monoblock, with the complete refrigeration circuit located outdoors. For a complete system, depending on the concept, a hydraulic station or a uniTOWER, a hot water tank and the system control are added. We can put together a suitable package on request.

Where can I buy the Vaillant heat pump?

At SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on the design. Shipping within Austria is free for orders over €5,000.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download
Vorschau Scrollen im PDF möglich · Vollbild über das Öffnen-Symbol