ELTAKO  Art.Nr: 15473230840139

ELTAKO Staircase Light Timer 1 NO Contact 16 A/250V AC – 23100832

Regular price
Regular price € 51,68 inkl. USt.
€ 43,07 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

1 NO contact, not floating, 16A/250V AC, 230V LED lamps up to 600W, ESL up to 200W, incandescent lamps up to 2300W. Control voltage 230V and/or 8..230V UC. Switch-off pre-warning and push-button continuous light can be switched on. Stand-by loss only 0.7 Watts. With ESL optimisation and multi-function. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 1 module = 18mm wide, 58mm deep. Zero-crossing switching to protect contacts and lamps. The noiseless electronics do not bother even the most sensitive ear – in contrast to many synchronous motors with mechanical gears. Due to the use of a bistable relay, there is no coil power loss and no heating in the switched-on state. After installation, wait for the automatic short synchronisation before connecting the switched consumer to the mains. Control, supply and switching voltage 230V. Additionally with galvanically isolated universal control voltage 8..230 V UC. For 3- and 4-wire circuits, re-triggerable, with attic lighting in 4-wire circuits. Automatic detection of the circuit type. Glim-lamp current up to 50mA, depending on the ignition voltage of the glim-lamps. Precise time setting 1 to 30 minutes with minute scale. Continuous light switch with the large rotary switch. After a power failure in the TLZ function setting, the lighting is switched on again if the time has not yet expired. With double terminals for push-button and lamp, so that connection can be made optionally at the top and bottom or only at the bottom. When the switch-off pre-warning is activated, the lighting flickers for approx. 30 seconds before the time expires and a total of 3 times at shortening intervals. With activated push-button continuous light, continuous light can be switched on by pressing the button for longer than 1 second, which is automatically switched off after 60 minutes or can be switched off by pressing the button for longer than 2 seconds. If push-button continuous light and switch-off pre-warning are activated, the switch-off pre-warning only occurs after the continuous light has been switched off. If energy-saving lamps (ESL) are switched entirely or partially, set the switch-off pre-warning and the push-button continuous light on the right ESL side of the rotary switch. Within the first second after switching on or re-triggering, in the TLZ functions, the time can be extended by pressing the button briefly up to 3 times (pumping). Each press adds the set time once. With multi-function: Switchable to ES (impulse switch), ER (relay) and ESV (impulse switch with fall-back delay) functions. In the ESV function, the times (t) adjustable with the middle rotary switch correspond to the following values: 1 = 2 min, 2 = 5 min, 3 = 10 min, 4 = 15 min, 6 = 25 min, 8 = 35 min, 10 = 45 min, 12 = 60 min, 20 = 90 min, 30 = 120 min. After the set delay time has expired, it is automatically switched off if the manual off command has not been given. Switch-off pre-warning and push-button continuous light can also be activated for ESV. Forgotten continuous light is switched off after 2 hours.

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen
Datenblatt
Hinweis: Der Link kann je nach Hersteller direkt einen Download starten.
Öffnen / Download

Technische Parameter

Produkteigenschaften ETIM

Ursprungsland
CN
Zolltarifnummer
85364900
eClass
27144000
eClass Bezeichnung
Installationsschalterprogramm
Serien
Treppenlichtschalter
ETIM-Klasse
Treppenlichtzeitschalter
Funktion
elektronisch mit Ausschaltvorwarnung
Montageart
DIN-Schiene
Breite in Teilungseinheiten
1
Einbautiefe
58 mm
Anzahl der Kontakte als Schließer
1
Anzahl der Kontakte als Öffner
0
Anzahl der Kontakte als Wechsler
0
Steuerspannung 1
230 - 230 V
Steuerspannungsart 1
AC
Frequenz der Steuerspannung 1
50 - 50 Hz
Steuerspannung 2
8 - 230 V
Steuerspannungsart 2
AC/DC
Bemessungsschaltstrom
1.6 A
Rückfallverzögerung
1 - 12 min
Taster Glimmlampenstrom
50 mA
Schaltungsart
3- und 4-Leiter-Schaltung
Ausschaltvorwarnung
flackern
Stromstoßfunktion wählbar
Ja
Nachschaltung
nachschaltbar + Dauerlicht + Zeitverlängerung
Versorgungsspannung
230 - 230 V
Spannungsart der Versorgungsspannung
AC
Max. Glühlampenlast
400 W
Max. Leuchtstofflampenlast (parallel kompensiert)
400 VA
Max. Schaltleistung LED
200 W
Leistungsaufnahme
600 W