{"product_id":"panasonic-panasonic-warmepumpe-r290-aquarea-m-luft-wasser-t-cap-25-kw-aussengerat-wh-wxg25me8-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic Heat Pump R290 Aquarea M Air\/Water T-CAP, 25 kW, Outdoor Unit – WH-WXG25ME8","description":"\u003cp\u003ePanasonic Hydrosplit Aquarea Big T-CAP heat pump, three-phase, inverter-controlled, R290 \u003cbr\u003eController module\u003cbr\u003eController module for air\/water heat pump in hydrosplit design for use with R290 and with a three-phase 400 V \/ 50 Hz mains connection\u003cbr\u003e\u003cbr\u003eOperating modes\u003cbr\u003eHeating, hot water, cooling (cooling mode can be activated via settings)\u003cbr\u003e\u003cbr\u003eOutdoor unit\u003cbr\u003eOutdoor unit for air\/water heat pump in hydrosplit design with R290 refrigerant and a three-phase 400 V \/ 50 Hz mains connection. The casing is made of galvanized and stove-enameled sheet steel in anthracite gray (RAL 7016), is suitable for outdoor installation and has a removable casing cover for easy access to internal components. The base plate has mounting lugs and condensate openings.\u003cbr\u003eThe axial fan has an enlarged fan diameter for consistent airflow to reduce fan speed and is driven by a continuously variable DC motor and an acoustically and aerodynamically optimized plastic impeller. A gas\/liquid separator is present in the outdoor unit. Pressure resistance and leak tightness are factory-tested and provided with an environmentally friendly basic refrigerant charge. The design requirements according to IEC 60335-2-40: 2022 are met. The heat exchanger consists of copper pipes with pressed-on Bluefin-coated aluminum fins. A 4-pole synchronous motor compressor and a 4-point vibration damper device, as well as soundproof compressor material, ensure a reduction in vibrations and noise. An electronic expansion valve, 4-way reversing valve, filter dryer, and shut-off valves with test connection are included. Line lengths of up to 30 m and height differences of up to 30 m between indoor and outdoor units are permitted.\u003cbr\u003e\u003cbr\u003eHydraulic circuit\u003cbr\u003eThe plate heat exchanger is made of stainless steel. The circulation pump, a Panasonic high-efficiency pump, is driven by a continuously controlled DC motor. Flow monitoring is present. A vortex flow meter for dynamic adjustment of the water flow rate depending on the specified temperature spread is present, as well as an integrated dirty water magnetic filter for the water circuit and a thermal overcurrent release. Up to three electric heating elements with 3 to 6 kW output can be installed on site in the domestic hot water or buffer tank. Built-in safety and vent valve, as well as water pressure sensor for measuring system pressure. Flow temperatures of up to 75 °C are possible. The operating range in heating mode extends down to -28°C. A water outlet temperature of 55°C is achieved at an outdoor temperature of up to -25°C. In cooling mode, the operating range is between 10°C and 43°C outdoor temperature. With T-CAP technology, the nominal heating capacity remains constant at an outdoor temperature of up to -20°C. System safety is enhanced by the hydraulic connection to the indoor unit and the separation of refrigerant in the outdoor unit and electronics in the indoor unit.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eTechnical changes and errors reserved\u003cbr\u003eControl\u003cbr\u003eModulating power adjustment of the compressor through inverter control technology. \u003cbr\u003eHigh energy efficiency due to starting operation in the partial load range and demand-controlled frequency increase. Equipped with temperature sensors for outdoor temperature, compressor, hot gas, and suction line temperatures, as well as evaporator temperature. A circuit reversal method ensures rapid and efficient defrosting of the outdoor unit heat exchanger. Communication modules for optimal data exchange with the hydromodule.\u003cbr\u003eSeparate heating and\/or domestic hot water control with a clear control panel and easy-to-understand symbols, as well as plain text menu displays in 26 different user languages. Continuous display of outdoor and flow temperatures, as well as outdoor temperature-dependent adjustment of the flow temperature in heating mode are available. Temperature sensors for condenser, flow, and return temperatures. Display of system pressure, weekly timer for time-dependent on\/off switching and operating mode pre-selection. A programmable timer is available for thermal disinfection. The control of the electric auxiliary heating is demand-oriented. \u003cbr\u003e\u003cbr\u003eAdditional functions\u003cbr\u003e•Automatic mode (heating\/cooling)\u003cbr\u003e•Holiday mode\u003cbr\u003e•Screed drying program\u003cbr\u003e•Power consumption display\u003cbr\u003e•Improved defrost function\u003cbr\u003e•Hot water circulation\u003cbr\u003e•Anti-stick mode (prevents components from seizing due to non-use)\u003cbr\u003e•Finer adjustment of the start sequence\u003cbr\u003e\u003cbr\u003eSelf-diagnosis system with error code display. Communication modules for optimal data exchange with the outdoor unit.\u003cbr\u003eOptional board for additional functions such as Smart Grid control, power control via 0-10 V signal, control of two heating circuits including heating circuit pumps and mixing valves, solar thermal, external switching between heating and cooling. Smart Cloud adapter.\u003cbr\u003eSetting for prioritizing quiet operation possible, so that a certain noise level is not exceeded.\u003cbr\u003e\u003cbr\u003eExternal connection options:\u003cbr\u003e•Optional board for additional functions\u003cbr\u003e•Control input for external on\/off switching \u003cbr\u003e•Control input for external room thermostat\u003cbr\u003e•Control output for 2-way valve (cooling mode)\u003cbr\u003e•Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e•Interface for communication with the Panasonic Smart Cloud\u003cbr\u003e\u003cbr\u003eElectrical equipment:\u003cbr\u003e•Electric auxiliary heating\u003cbr\u003e•Thermal overload protection for electric auxiliary heating \u003cbr\u003e•RCD circuit breaker\u003cbr\u003e•Control inputs and outputs\u003cbr\u003e\u003cbr\u003eConformity with EU directives \u003cbr\u003eThe device complies with the relevant EU directives and standards.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eTechnical changes and errors reserved.\u003cbr\u003e\u003cbr\u003eTechnical data\u003cbr\u003eHeating capacity \/ COP (A7\/W35) 25 kW \/ 4.80\u003cbr\u003eHeating capacity \/ COP (A7\/W55) 25 kW \/ 3.0\u003cbr\u003eHeating capacity \/ COP (A2\/W35) 25 kW \/ 2.80\u003cbr\u003eHeating capacity \/ COP (A2\/W55) 25 kW \/ 1.97\u003cbr\u003eHeating capacity \/ COP (A–7\/W35) 25 kW \/2.36\u003cbr\u003eHeating capacity \/ COP (A–7\/W55) 25 kW \/ 1.80\u003cbr\u003eHeating capacity (A–20\/W55) 25 kW\u003cbr\u003eCooling capacity \/ EER (A35\/W7) 25 kW \/ 2.86\u003cbr\u003eCooling capacity \/ EER (A35\/W18) 25 kW \/ 4.47\u003cbr\u003eSeasonal room heating energy efficiency (ηs,h), moderate climate, W35 \/ W55 167 % \/ 140 %\u003cbr\u003eSCOP 4.36 \/ 3.59\u003cbr\u003eEnergy efficiency class heating, moderate climate, scale: A+++ to D, W35 \/ W55 A++ \/ A++\u003cbr\u003eOutdoor unit\u003cbr\u003e\u003cbr\u003eSound power level (partial load, ErP, A7\/W55) 2 Heating dB(A) 59\u003cbr\u003eSound power level (full load, ErP) Heating dB(A) 69\u003cbr\u003eDimensions \/ Net weight H x W x D mm \/ kg 1645 x 1500 x 460 \/ 240\u003cbr\u003ePre-filled refrigerant quantity (R290) \/ CO2 equivalent 3kg \/ t 3.00 \/ 0.009\u003cbr\u003eOperating range outdoor temperature °C –28 \/ +43\u003cbr\u003eWater outlet temp. heating (min. \/ max.) °C 25 \/ 75 \u003cbr\u003eWater outlet temp. cooling (min. \/ max.) °C 5 \/ 20\u003cbr\u003eHigh-efficiency pump speed levels variable\u003cbr\u003eRecommended RCD for mains connection 50 A\u003cbr\u003eRecommended cable cross-section (min.) for mains connection mm² 5x10-5x16\u003cbr\u003e1) Observe local regulations. 2) Sound power level according to EN12102 under conditions according to EN14825. 3) WH-WXG models are hermetically sealed\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294391972171,"sku":"PAWHWXG25ME8","price":20414.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/NDQyNDQwNQ.png?v=1787129569","url":"https:\/\/solarvic.at\/en\/products\/panasonic-panasonic-warmepumpe-r290-aquarea-m-luft-wasser-t-cap-25-kw-aussengerat-wh-wxg25me8-verkaufseinheit-1-stuck","provider":"SOLARVIC | Photovoltaik \u0026 Haustechnik","version":"1.0","type":"link"}