{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-hp-1ph-5-kw-aussengerat-wh-udz05ke5-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic A\/W Heat Pump Aquarea K HP, 1ph, 5 kW, Outdoor Unit – WH-UDZ05KE5","description":"\u003cp\u003eAir-to-water heat pump in split design\u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir-to-water heat pump for heating, domestic hot water preparation, and cooling (cooling mode can be activated via settings), consisting of an outdoor unit and an indoor unit (combi hydro module), which is a combination of a hydro module and a hot water tank.\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit\u003cbr\u003e\nOutdoor unit for air-to-water heat pump in split design, 230 V, R32\u003cbr\u003e\nHousing made of galvanized and stove-enamelled sheet steel RAL 7016, for outdoor installation, removable housing cover for easy access to internal components. Base plate with mounting tabs and condensate opening.\u003cbr\u003e\nAxial fan with continuously variable DC motor and a sound- and flow-optimized plastic impeller.\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Air-cooled heat exchanger made of copper pipes with corrugated aluminum fins with coating. Double-rotary compressor, sound-insulated and vibration-damped mounted, and equipped with a pressure-side silencer. Electronic expansion valve, 4-way reverse cycle valve, filter drier, and shut-off valves with test port. Factory tested for pressure resistance and leak tightness and pre-filled with refrigerant. Long line lengths up to 40 m and height differences up to 30 m between indoor and outdoor unit are permissible.\u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nPlate heat exchanger made of stainless steel. Circulating pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of water flow in relation to the specified temperature spread, integrated dirty water magnetic filter for the water circuit, electric heating rod with thermal overcurrent trip. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi hydro module is 60 °C and is reached even down to -10 °C ambient temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating operation up to -20 °C, cooling operation up to +10 °C ambient temperature possible. The maximum water temperature in the domestic hot water tank is 65 °C.\u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet and hot water outlet of the hot water tank are routed in a row side-by-side upwards out of the unit.\u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating compressor output adjustment via INVERTER+ control electronics. Temperature sensors for outdoor temperature, compressor, hot gas and suction line temperature, and evaporator temperature. Higher efficiency, as the compressor starts in partial load operation and the compressor frequency is increased if necessary, reverse cycle for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting behavior through bypass defrosting. Communication modules for optimal data exchange with the hydro module. Electronic manometer provides value in electronic form for transmission via WLAN.\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\u003c!--nl\"\/\u003e• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with the Aquarea Smart Cloud (CZ-TAW1B) Electrical equipment:\u003cbr\u003e\n• Electric auxiliary heater 3kW\u003cbr\u003e\n• Thermal overload protection for electric auxiliary heater\u003cbr\u003e\n• RCD\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Other functions: weekly timer, holiday programs, secondary pump control, bivalence control, optional temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (priority quiet mode \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrost function, during defrost operation the heat pump can switch to hot water mode.\u003cbr\u003e\nSeparate heating or domestic hot water control with a clear control panel (controller) with a backlit 3.5-inch display and keypad with touch buttons. Easy-to-understand symbols and plain text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Weekly timer for time-dependent on\/off switching and operating mode pre-selection. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.\u003cbr\u003e\nConformity with EU directives\u003cbr\u003e\nThe device complies with the relevant EU directives and standards.\u003cbr\u003e\n\u003cbr\u003e\nTechnical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 5.00 kW\/ 5.10\u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 5.00 kW\/ 3.03\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 5.00 kW\/ 3.57\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 5.00 kW \/ 2.29\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 5.00 kW \/ 2.79\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 5.00 kW \/ 1.89\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 5.00 kW \/ 3.05\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 5.00 kW \/ 4.90\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), average climate, W35 \/ W55 202 % \/142 % SCOP 5.12 \/ 3.63\u003cbr\u003e\nEnergy efficiency class heating, average climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 237% \/ 165% SCOP 6.00 \/ 4.20\u003cbr\u003e\u003c!--nl'\u003eEnergy efficiency class heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 160 % \/ 115 % SCOP 4.08 \/ 2.95\u003cbr\u003e\nEnergy efficiency class heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A+\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UDZ05KE5\u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 55\u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62\/\u003cbr\u003e\nDimensions \/ Net weight H x W x D mm \/ kg 795 x 875 x 380 \/ 55\u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 1.3 \/ 0.878\u003cbr\u003e\nLine diameter Liquid line \/ Suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (5\/8)\u003cbr\u003e\nLine length (min. – max.) at -25°C m 3– 40\u003cbr\u003e\nHeight difference IG\/AG (max.) m 30\u003cbr\u003e\nOperating range outdoor temperature °C –25 \/ +35\u003cbr\u003e\nWater outlet temp. Heating \/ Cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294497059147,"sku":"PAWHUDZ05KE5","price":2504.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/5120b3683733c532730ce60878bed9c4.webp?v=1768552835","url":"https:\/\/solarvic.at\/en\/products\/panasonic-panasonic-l-w-warmepumpe-aquarea-k-hp-1ph-5-kw-aussengerat-wh-udz05ke5-verkaufseinheit-1-stuck","provider":"SOLARVIC | Photovoltaik \u0026 Haustechnik","version":"1.0","type":"link"}