{"product_id":"enwitec-uss-dc-typ-i-ii-1-mpp-tracker-10012868","title":"Enwitec SPD DC Type I+II, 1 MPP-Tracker - 10012868","description":"\u003cstyle\u003e\n@import url('https:\/\/fonts.googleapis.com\/css2?family=DM+Sans:wght@400;500;600;700\u0026display=swap');\n.sv-product{font-family:'DM Sans',sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6}\n.sv-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin-bottom:28px}\n@media(max-width:600px){.sv-stats{grid-template-columns:repeat(2,1fr)}}\n.sv-stat{background:#0c0c0c;border-radius:12px;padding:20px 16px;text-align:center}\n.sv-stat-val{font-size:28px;font-weight:700;color:#fff;line-height:1.1}\n.sv-stat-val span{font-size:16px;font-weight:400;color:rgba(255,255,255,0.5)}\n.sv-stat-label{font-size:12px;color:rgba(255,255,255,0.4);margin-top:6px}\n.sv-section{margin-bottom:28px}\n.sv-section-title{font-size:18px;font-weight:700;color:#0c0c0c;margin:0 0 16px;padding-left:14px;border-left:3px solid #dc2626}\n.sv-features{display:grid;grid-template-columns:repeat(2,1fr);gap:12px}\n@media(max-width:600px){.sv-features{grid-template-columns:1fr}}\n.sv-feature{background:#f8f8f8;border-radius:12px;padding:20px;display:flex;align-items:flex-start;gap:14px}\n.sv-feature-icon{min-width:40px;height:40px;border-radius:10px;background:rgba(220,38,38,0.08);display:flex;align-items:center;justify-content:center;font-size:18px;color:#dc2626}\n.sv-feature h4{font-size:14px;font-weight:600;color:#1a1a1a;margin:0 0 4px}\n.sv-feature p{font-size:13px;color:#666;margin:0;line-height:1.5}\n.sv-table-wrap{border:1px solid #e5e5e5;border-radius:12px;overflow:hidden}\n.sv-table{width:100%;border-collapse:collapse;font-size:14px}\n.sv-table thead th{background:#0c0c0c;color:#fff;font-weight:600;padding:14px 18px;text-align:left;font-size:13px}\n.sv-table tbody tr{border-bottom:1px solid #f0f0f0}\n.sv-table tbody tr:last-child{border-bottom:none}\n.sv-table tbody tr:nth-child(even){background:#fafafa}\n.sv-table td{padding:12px 18px;color:#333}\n.sv-table td:first-child{font-weight:500;color:#1a1a1a;width:45%}\n.sv-highlight{color:#dc2626;font-weight:600}\n.sv-warranty{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin-bottom:28px}\n@media(max-width:600px){.sv-warranty{grid-template-columns:1fr}}\n.sv-warranty-card{background:linear-gradient(135deg,#0c0c0c,#1a1a1a);border-radius:12px;padding:24px 20px;text-align:center}\n.sv-warranty-val{font-size:32px;font-weight:700;color:#ef4444;line-height:1}\n.sv-warranty-unit{font-size:14px;color:rgba(255,255,255,0.5);margin-top:4px}\n.sv-warranty-label{font-size:12px;color:rgba(255,255,255,0.35);margin-top:8px;line-height:1.4}\n.sv-badges{display:flex;flex-wrap:wrap;gap:8px;margin-bottom:28px}\n.sv-badge{display:inline-flex;align-items:center;gap:6px;background:#f0f0f0;border-radius:8px;padding:8px 14px;font-size:12px;font-weight:500;color:#333}\n.sv-badge-dot{width:6px;height:6px;border-radius:50%;background:#22c55e}\n.sv-seo{font-size:14px;color:#555;line-height:1.8;margin-top:32px;padding-top:24px;border-top:1px solid #eee}\n.sv-seo h4{font-size:15px;font-weight:600;color:#1a1a1a;margin:20px 0 8px}\n.sv-faq{margin-top:0;padding-top:0;border-top:none}\n.sv-faq-item{background:#f8f8f8;border-radius:12px;padding:20px;margin-bottom:12px}\n.sv-faq-item summary{font-size:14px;font-weight:600;color:#1a1a1a;cursor:pointer;list-style:none;display:flex;align-items:center;gap:10px}\n.sv-faq-item summary::-webkit-details-marker{display:none}\n.sv-faq-item summary::before{content:'';display:inline-block;width:8px;height:8px;border-right:2px solid #dc2626;border-bottom:2px solid #dc2626;transform:rotate(-45deg);transition:transform 0.2s;flex-shrink:0}\n.sv-faq-item[open] summary::before{transform:rotate(45deg)}\n.sv-faq-item p{font-size:13px;color:#555;margin:12px 0 0 18px;line-height:1.7}\n\u003c\/style\u003e\n\u003cdiv class=\"sv-product\"\u003e\n\n\u003cdiv class=\"sv-stats\"\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003eDC Type I+II \u003cspan\u003e✓\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eProtection Class\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e1 \u003cspan\u003epc\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMPP Tracker\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003ePV \u003cspan\u003eDC\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eApplication\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003eDIN rail \u003cspan\u003e✓\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMounting\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eAdvantages at a glance\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-features\"\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e⚡\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eCombined Type I+II\u003c\/h4\u003e\n\n\u003cp\u003eSurge arrester of the combined class Type I+II for the DC side of PV systems - protects against direct and indirect lightning strikes.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔌\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eFor 1 MPP tracker\u003c\/h4\u003e\n\n\u003cp\u003ePre-assembled DC wiring suitable for inverters with one MPP tracker.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🛡️\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eDevice protection DC side\u003c\/h4\u003e\n\n\u003cp\u003eDiverts surges from lightning and switching operations, thus protecting inverters and module strings.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🧰\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eReady for connection\u003c\/h4\u003e\n\n\u003cp\u003ePre-assembled module from Enwitec - reduces wiring effort during installation.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e📏\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eDIN rail mounting\u003c\/h4\u003e\n\n\u003cp\u003eDesigned for installation in meter cabinets and distributors on DIN rails.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🇪🇺\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eEnwitec quality\u003c\/h4\u003e\n\n\u003cp\u003eSurge protection from Enwitec Electronic, specialized in PV system technology.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eTechnical data\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eParameter\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\n\u003ctd\u003eDC surge protection device (SPD)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\n\u003ctd\u003eType I+II (combined arrester)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eApplication side\u003c\/td\u003e\n\n\u003ctd\u003eDC \/ PV generator\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDesign\u003c\/td\u003e\n\n\u003ctd\u003efor 1 MPP tracker\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMounting\u003c\/td\u003e\n\n\u003ctd\u003eDIN rail (distributor\/meter cabinet)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\n\u003ctd\u003eEnwitec Electronic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eManufacturer part number\u003c\/td\u003e\n\n\u003ctd\u003e10012868\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-seo sv-faq\"\u003e\n\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhat is the Enwitec SPD DC Type I+II?\u003c\/summary\u003e\u003cp\u003eIt is a surge protection device (SPD) from Enwitec Electronic for the DC side of a photovoltaic system. As a combined arrester of class Type I+II, it diverts surges from direct and indirect lightning strikes as well as from switching operations, thus protecting the connected inverter and module strings.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eFor which systems is this surge protection suitable?\u003c\/summary\u003e\u003cp\u003eThe module is pre-assembled for the DC side of PV systems with one MPP tracker and is suitable for installation in distributors and meter cabinets on a DIN rail.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhat does Type I+II mean?\u003c\/summary\u003e\u003cp\u003eType I+II refers to a combined lightning current and surge arrester: Type I protects against direct lightning strikes (partial lightning currents), Type II against surges from nearby strikes and switching operations. The combination covers both cases in one device.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhere is the surge protection mounted?\u003c\/summary\u003e\u003cp\u003eThe SPD is mounted on a DIN rail in the PV generator connection box, in the distributor or in the meter cabinet and integrated into the DC wiring between the module string and the inverter. Installation must be carried out by a qualified electrician.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWho is Enwitec Electronic?\u003c\/summary\u003e\u003cp\u003eEnwitec Electronic is a manufacturer of electrical engineering components for photovoltaics, including switching and grid disconnection solutions, as well as surge protection systems for use in solar installations.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhere can I buy DC surge protection in Austria?\u003c\/summary\u003e\u003cp\u003eThe Enwitec SPD DC Type I+II and other PV accessories are available online from SOLARVIC at solarvic.at.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eHow can I order?\u003c\/summary\u003e\u003cp\u003eDirectly online via solarvic.at -- for questions about the design, the SOLARVIC team will be happy to help.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Was ist der Enwitec ÜSS DC Typ I+II?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Es handelt sich um einen Überspannungsschutz (ÜSS) von Enwitec Electronic für die Gleichstromseite einer Photovoltaikanlage. Als Kombi-Ableiter der Klasse Typ I+II leitet er Überspannungen aus direktem und indirektem Blitzeinschlag sowie aus Schaltvorgängen ab und schützt so den angeschlossenen Wechselrichter und die Modulstränge.\"}},{\"@type\":\"Question\",\"name\":\"Für welche Anlagen eignet sich dieser Überspannungsschutz?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Die Baugruppe ist für die DC-Seite von PV-Anlagen mit einem MPP-Tracker vorkonfektioniert und eignet sich für den Einbau in Verteiler und Zählerschränke auf DIN-Hutschiene.\"}},{\"@type\":\"Question\",\"name\":\"Was bedeutet Typ I+II?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Typ I+II bezeichnet einen kombinierten Blitzstrom- und Überspannungsableiter: Typ I schützt vor direkten Blitzeinschlägen (Teilblitzströmen), Typ II vor Überspannungen durch nahe Einschläge und Schalthandlungen. Die Kombination deckt beide Fälle in einem Gerät ab.\"}},{\"@type\":\"Question\",\"name\":\"Wo wird der Überspannungsschutz montiert?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Der ÜSS wird auf einer DIN-Tragschiene im PV-Generatoranschlusskasten, im Verteiler oder im Zählerschrank montiert und in die DC-Verkabelung zwischen Modulstrang und Wechselrichter eingebunden. Die Installation gehört in die Hände einer Elektrofachkraft.\"}},{\"@type\":\"Question\",\"name\":\"Wer ist Enwitec Electronic?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Enwitec Electronic ist ein Hersteller von elektrotechnischen Komponenten für die Photovoltaik, darunter Umschalt- und Netztrennlösungen sowie Überspannungsschutzsysteme für den Einsatz in Solaranlagen.\"}},{\"@type\":\"Question\",\"name\":\"Wo kann ich DC-Überspannungsschutz in Österreich kaufen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Den Enwitec ÜSS DC Typ I+II sowie weiteres PV-Zubehör erhalten Sie bei SOLARVIC online unter solarvic.at.\"}},{\"@type\":\"Question\",\"name\":\"Wie kann ich bestellen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Direkt online über solarvic.at -- bei Fragen zur Auslegung hilft das SOLARVIC-Team gerne weiter.\"}}]}\u003c\/script\u003e","brand":"Enwitec Electronic","offers":[{"title":"Default Title","offer_id":58212940251467,"sku":"10012868","price":182.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/b07a71294de070c8441a5b4ac5884c68.jpg?v=1787302120","url":"https:\/\/solarvic.at\/en\/products\/enwitec-uss-dc-typ-i-ii-1-mpp-tracker-10012868","provider":"SOLARVIC | Photovoltaik \u0026 Haustechnik","version":"1.0","type":"link"}