{"title":"Heat Pump Air\/Water Split","description":null,"products":[{"product_id":"vaillant-vaillant-luft-wasser-warmepumpe-7-kw-ae-arotherm-split-plus-vwl-75-8-2-as-230v-0010039758-verkaufseinheit-1-stuck","title":"VAILLANT Vaillant Air\/Water Heat Pump 7 kW AE aroTHERM Split plus VWL 75\/8.2 AS 230V – 0010039758 DACH Version","description":"\u003cstyle\u003e@import url('https:\/\/fonts.googleapis.com\/css2?family=DM+Sans:wght@400;500;600;700\u0026display=swap');.sv-product{font-family:'DM Sans',sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6}.sv-dach{display:flex;align-items:center;gap:18px;background:linear-gradient(135deg,#0f0f0f,#282828);border:1px solid rgba(255,255,255,.09);border-radius:14px;padding:18px 22px;margin-bottom:26px}.sv-dach-flags{flex:0 0 auto;display:flex;gap:7px}.sv-dach-flags svg{width:32px;height:22px;border-radius:3px;box-shadow:0 0 0 1px rgba(255,255,255,.3),0 2px 6px rgba(0,0,0,.4);display:block}.sv-dach-body{min-width:0}.sv-dach-head{display:flex;align-items:center;gap:10px;flex-wrap:wrap;margin-bottom:5px}.sv-dach-head b{font-size:16.5px;font-weight:700;color:#fff}.sv-dach-tag{font-size:10px;font-weight:700;letter-spacing:.12em;color:#fff;background:#dc2626;border-radius:999px;padding:4px 10px;line-height:1}.sv-dach-sub{display:block;font-size:13px;line-height:1.55;color:rgba(255,255,255,.66)}@media(max-width:600px){.sv-dach{flex-direction:column;align-items:flex-start;gap:14px;padding:16px 18px}}.sv-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin-bottom:28px}@media(max-width:600px){.sv-stats{grid-template-columns:repeat(2,1fr)}}.sv-stat{background:#0c0c0c;border-radius:12px;padding:20px 16px;text-align:center}.sv-stat-val{font-size:26px;font-weight:700;color:#fff;line-height:1.1}.sv-stat-val span{font-size:15px;font-weight:400;color:rgba(255,255,255,0.5)}.sv-stat-label{font-size:12px;color:rgba(255,255,255,0.4);margin-top:6px}.sv-section{margin-bottom:28px}.sv-section-title{font-size:18px;font-weight:700;color:#0c0c0c;margin:0 0 16px;padding-left:14px;border-left:3px solid #dc2626}.sv-features{display:grid;grid-template-columns:repeat(2,1fr);gap:12px}@media(max-width:600px){.sv-features{grid-template-columns:1fr}}.sv-feature{background:#f8f8f8;border-radius:12px;padding:20px;display:flex;align-items:flex-start;gap:14px}.sv-feature-icon{min-width:40px;height:40px;border-radius:10px;background:rgba(220,38,38,0.08);display:flex;align-items:center;justify-content:center;font-size:18px;color:#dc2626}.sv-feature h4{font-size:14px;font-weight:600;color:#1a1a1a;margin:0 0 4px}.sv-feature p{font-size:13px;color:#666;margin:0;line-height:1.5}.sv-table-wrap{border:1px solid #e5e5e5;border-radius:12px;overflow:hidden;margin-bottom:16px}.sv-table{width:100%;border-collapse:collapse;font-size:14px}.sv-table thead th{background:#0c0c0c;color:#fff;font-weight:600;padding:14px 18px;text-align:left;font-size:13px}.sv-table tbody tr{border-bottom:1px solid #f0f0f0}.sv-table tbody tr:last-child{border-bottom:none}.sv-table tbody tr:nth-child(even){background:#fafafa}.sv-table td{padding:12px 18px;color:#333}.sv-table td:first-child{font-weight:500;color:#1a1a1a;width:52%}.sv-highlight{color:#dc2626;font-weight:600}.sv-note{background:#fff8e6;border:1px solid #efd9a0;border-radius:12px;padding:18px 20px;font-size:13.5px;line-height:1.65;color:#5c4a1c;margin-bottom:28px}.sv-note strong{color:#3d3210}.sv-seo{font-size:14px;color:#555;line-height:1.8;margin-top:32px;padding-top:24px;border-top:1px solid #eee}.sv-seo h4{font-size:15px;font-weight:600;color:#1a1a1a;margin:20px 0 8px}.sv-faq{margin-top:0;padding-top:0;border-top:none}.sv-faq-item{background:#f8f8f8;border-radius:12px;padding:20px;margin-bottom:12px}.sv-faq-item summary{font-size:14px;font-weight:600;color:#1a1a1a;cursor:pointer;list-style:none;display:flex;align-items:center;gap:10px}.sv-faq-item summary::-webkit-details-marker{display:none}.sv-faq-item summary::before{content:'';display:inline-block;width:8px;height:8px;border-right:2px solid #dc2626;border-bottom:2px solid #dc2626;transform:rotate(-45deg);transition:transform 0.2s;flex-shrink:0}.sv-faq-item[open] summary::before{transform:rotate(45deg)}.sv-faq-item p{font-size:13px;color:#555;margin:12px 0 0 18px;line-height:1.7}\u003c\/style\u003e\n\u003cdiv class=\"sv-product\"\u003e\n\n\u003cdiv class=\"sv-dach\"\u003e\n\n\u003cspan class=\"sv-dach-flags\"\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"7\" fill=\"#000000\"\u003e\u003c\/rect\u003e\u003crect y=\"7\" width=\"30\" height=\"7\" fill=\"#DD0000\"\u003e\u003c\/rect\u003e\u003crect y=\"14\" width=\"30\" height=\"7\" fill=\"#FFCE00\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"21\" fill=\"#ED2939\"\u003e\u003c\/rect\u003e\u003crect y=\"7\" width=\"30\" height=\"7\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"21\" fill=\"#D52B1E\"\u003e\u003c\/rect\u003e\u003crect x=\"13\" y=\"4.5\" width=\"4\" height=\"12\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003crect x=\"9\" y=\"8.5\" width=\"12\" height=\"4\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003c\/span\u003e\n\u003cspan class=\"sv-dach-body\"\u003e\u003cspan class=\"sv-dach-head\"\u003e\u003cb\u003eDACH Version\u003c\/b\u003e\u003cspan class=\"sv-dach-tag\"\u003eGermany · Austria · Switzerland\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"sv-dach-sub\"\u003eControl and documentation in German, mains connection 230 V \/ 50 Hz according to Central European standard – usable in all three countries.\u003c\/span\u003e\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stats\"\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e5.07 \u003cspan\u003ekW\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eHeating output at A7\/W35\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e5.2 \u003cspan\u003eCOP\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eCoefficient of Performance at A7\/W35\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e62 \u003cspan\u003e°C\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMax. flow temperature\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e40 \u003cspan\u003em\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMax. line length\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-note\"\u003e\n\n\u003cstrong\u003ePlease note: Outdoor unit, not a complete system.\u003c\/strong\u003e The VWL 75\/8.2 AS is the split outdoor unit. For a ready-to-operate system, an indoor unit – hydraulic station or uniTOWER – as well as refrigerant lines and system control are required. We will gladly put together a suitable package upon request.\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eAdvantages at a glance\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-features\"\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e⚡\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eCOP 5.2 at A7\/W35\u003c\/h4\u003e\n\n\u003cp\u003e5.07 kW heating output with only 0.98 kW consumption. Even at −7 °C, the unit still delivers 6.39 kW with a COP of 3.1.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔧\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eSplit instead of Monoblock\u003c\/h4\u003e\n\n\u003cp\u003eOnly refrigerant lines run into the house, no water-carrying circuit to the outside. This eliminates the need for frost protection in the connecting line.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e📏\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eUp to 40 m line length\u003c\/h4\u003e\n\n\u003cp\u003eUp to 30 m height difference if the outdoor unit is at the top, 10 m if it's at the bottom. This allows for great flexibility in placement.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔊\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eWhisper-quiet operation\u003c\/h4\u003e\n\n\u003cp\u003e58 dB(A) maximum at A7\/W35, only 48.7 dB(A) in 60% whisper mode at A-7\/W35.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e❄️\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eActive cooling\u003c\/h4\u003e\n\n\u003cp\u003eIntegrated active cooling mode: 7.29 kW at A35\/W18 with EER 4.0, in component cooling mode 7.0 kW at A35\/W7.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔌\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003e230 V – no heavy-duty power required\u003c\/h4\u003e\n\n\u003cp\u003eSingle-phase connection with a maximum of 14 A and 3.2 kW electrical power consumption.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003ePerformance \u0026amp; Efficiency according to EN 14511\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eOperating point\u003c\/th\u003e\n\n\u003cth\u003eOutput \/ Consumption \/ COP or EER\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W35\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003e5.07 kW \/ 0.98 kW \/ 5.2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA2\/W35\u003c\/td\u003e\n\n\u003ctd\u003e3.13 kW \/ 0.71 kW \/ 4.4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA−7\/W35\u003c\/td\u003e\n\n\u003ctd\u003e6.39 kW \/ 2.06 kW \/ 3.1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W45\u003c\/td\u003e\n\n\u003ctd\u003e4.78 kW \/ 1.23 kW \/ 3.9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W55\u003c\/td\u003e\n\n\u003ctd\u003e6.45 kW \/ 2.08 kW \/ 3.1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCooling A35\/W18\u003c\/td\u003e\n\n\u003ctd\u003e7.29 kW \/ 1.82 kW \/ EER 4.0\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCooling A35\/W7\u003c\/td\u003e\n\n\u003ctd\u003e7.00 kW \/ 2.69 kW \/ EER 2.6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eTechnical Data\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eParameter\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eType of construction\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003eSplit outdoor unit (AS)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRefrigerant \/ pre-filled quantity \/ GWP\u003c\/td\u003e\n\n\u003ctd\u003eR32 \/ 1.5 kg \/ 675\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCO₂ equivalent\u003c\/td\u003e\n\n\u003ctd\u003e1.01 t\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eElectrical power consumption (max)\u003c\/td\u003e\n\n\u003ctd\u003e3.2 kW\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003ePower supply \/ Current (max)\u003c\/td\u003e\n\n\u003ctd\u003e230 V (50 Hz) \/ 14 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\n\u003ctd\u003eIP14B\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power level at A7\/W35 (max)\u003c\/td\u003e\n\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power level (ErP)\u003c\/td\u003e\n\n\u003ctd\u003e48.3 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power A−7\/W35 in 60% whisper mode\u003c\/td\u003e\n\n\u003ctd\u003e48.7 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSuction gas \/ liquid line connection\u003c\/td\u003e\n\n\u003ctd\u003e1\/2″ \/ 1\/4″\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\n\u003ctd\u003e960 × 1,100 × 450 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eWeight ready for operation \/ gross\u003c\/td\u003e\n\n\u003ctd\u003e100 kg \/ 121 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eOperating limits\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eParameter\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeating temperature\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003e5 – 62 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\n\u003ctd\u003emax. 55 °C, with auxiliary heating 70 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDistance between indoor and outdoor unit\u003c\/td\u003e\n\n\u003ctd\u003emax. 40 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeight difference, outdoor unit above\u003c\/td\u003e\n\n\u003ctd\u003emax. 30 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeight difference, outdoor unit below\u003c\/td\u003e\n\n\u003ctd\u003emax. 10 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-seo sv-faq\"\u003e\n\n\u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhat does the DACH version mean?\u003c\/summary\u003e\u003cp\u003eThe unit, control, and documentation are designed for the German-speaking region: menu navigation and documentation in German, mains connection 230 V \/ 50 Hz. This means the heat pump can be used equally in Germany, Austria, and Switzerland. Subsidies and registration requirements differ by country – your local installer will clarify this.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eSplit or monoblock – which is better?\u003c\/summary\u003e\u003cp\u003eWith the split system, only refrigerant flows between the outdoor and indoor units, so nothing can freeze. However, this requires a refrigerant connection and thus a refrigeration certificate for commissioning. A monoblock like the aroTHERM plus is hydraulically simpler but must be connected frost-proof.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhat refrigerant is used?\u003c\/summary\u003e\u003cp\u003eR32 with a GWP of 675 and 1.5 kg pre-fill, corresponding to 1.01 t CO₂ equivalent. If you prefer a natural refrigerant, the aroTHERM plus monoblock series offers units with R290 and a GWP of 0.02.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eDoes the 7 kW size fit my house?\u003c\/summary\u003e\u003cp\u003eThe VWL 75\/8.2 AS delivers 6.39 kW at −7 °C and 5.07 kW at 7 °C, each with a flow temperature of 35 °C. This is the typical size for a single-family house with a heating load of 6 to 8 kW. The exact sizing requires a heating load calculation according to EN 12831.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eHow far away can the outdoor unit be placed?\u003c\/summary\u003e\u003cp\u003eUp to 40 m of line length between the indoor and outdoor units. If the outdoor unit is higher, a height difference of up to 30 m is allowed; if it is lower, up to 10 m.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhere can I buy the Vaillant heat pump?\u003c\/summary\u003e\u003cp\u003eAt SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and advise on sizing. For orders over €5,000, shipping within Austria is free.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Was bedeutet die DACH Version?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Regelung und Dokumentation in Deutsch, Netzanschluss 230 V \/ 50 Hz - einsetzbar in Deutschland, Oesterreich und der Schweiz.\"}},{\"@type\":\"Question\",\"name\":\"Split oder Monoblock?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Beim Split laeuft nur Kaeltemittel nach draussen, nichts kann einfrieren. Dafuer braucht die Inbetriebnahme einen Kaelteschein.\"}},{\"@type\":\"Question\",\"name\":\"Welches Kaeltemittel wird verwendet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"R32 mit GWP 675, 1,5 kg vorgefuellt, entsprechend 1,01 t CO2-Aequivalent.\"}},{\"@type\":\"Question\",\"name\":\"Passt die 7-kW-Groesse zu meinem Haus?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"6,39 kW bei minus 7 Grad und 5,07 kW bei 7 Grad, jeweils 35 Grad Vorlauf - typisch fuer 6 bis 8 kW Heizlast.\"}}]}\u003c\/script\u003e","brand":"VAILLANT","offers":[{"title":"Default Title","offer_id":56294430507339,"sku":"VA0010039758","price":5630.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/HP23-aroTHERM_20Split_20plus-Rside_2001_5f4e52bc-b034-4f8a-af7b-3ee6e49ac959.png?v=1788089511"},{"product_id":"vaillant-vaillant-luft-wasser-warmepumpe-5-kw-ae-arotherm-split-plus-vwl-55-8-2-as-230v-0010039757-verkaufseinheit-1-stuck","title":"VAILLANT Vaillant Air\/Water Heat Pump 5 kW AE aroTHERM Split plus VWL 55\/8.2 AS 230V – 0010039757 DACH Version","description":"\u003cstyle\u003e@import url('https:\/\/fonts.googleapis.com\/css2?family=DM+Sans:wght@400;500;600;700\u0026display=swap');.sv-product{font-family:'DM Sans',sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6}.sv-dach{display:flex;align-items:center;gap:18px;background:linear-gradient(135deg,#0f0f0f,#282828);border:1px solid rgba(255,255,255,.09);border-radius:14px;padding:18px 22px;margin-bottom:26px}.sv-dach-flags{flex:0 0 auto;display:flex;gap:7px}.sv-dach-flags svg{width:32px;height:22px;border-radius:3px;box-shadow:0 0 0 1px rgba(255,255,255,.3),0 2px 6px rgba(0,0,0,.4);display:block}.sv-dach-body{min-width:0}.sv-dach-head{display:flex;align-items:center;gap:10px;flex-wrap:wrap;margin-bottom:5px}.sv-dach-head b{font-size:16.5px;font-weight:700;color:#fff}.sv-dach-tag{font-size:10px;font-weight:700;letter-spacing:.12em;color:#fff;background:#dc2626;border-radius:999px;padding:4px 10px;line-height:1}.sv-dach-sub{display:block;font-size:13px;line-height:1.55;color:rgba(255,255,255,.66)}@media(max-width:600px){.sv-dach{flex-direction:column;align-items:flex-start;gap:14px;padding:16px 18px}}.sv-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin-bottom:28px}@media(max-width:600px){.sv-stats{grid-template-columns:repeat(2,1fr)}}.sv-stat{background:#0c0c0c;border-radius:12px;padding:20px 16px;text-align:center}.sv-stat-val{font-size:26px;font-weight:700;color:#fff;line-height:1.1}.sv-stat-val span{font-size:15px;font-weight:400;color:rgba(255,255,255,0.5)}.sv-stat-label{font-size:12px;color:rgba(255,255,255,0.4);margin-top:6px}.sv-section{margin-bottom:28px}.sv-section-title{font-size:18px;font-weight:700;color:#0c0c0c;margin:0 0 16px;padding-left:14px;border-left:3px solid #dc2626}.sv-features{display:grid;grid-template-columns:repeat(2,1fr);gap:12px}@media(max-width:600px){.sv-features{grid-template-columns:1fr}}.sv-feature{background:#f8f8f8;border-radius:12px;padding:20px;display:flex;align-items:flex-start;gap:14px}.sv-feature-icon{min-width:40px;height:40px;border-radius:10px;background:rgba(220,38,38,0.08);display:flex;align-items:center;justify-content:center;font-size:18px;color:#dc2626}.sv-feature h4{font-size:14px;font-weight:600;color:#1a1a1a;margin:0 0 4px}.sv-feature p{font-size:13px;color:#666;margin:0;line-height:1.5}.sv-table-wrap{border:1px solid #e5e5e5;border-radius:12px;overflow:hidden;margin-bottom:16px}.sv-table{width:100%;border-collapse:collapse;font-size:14px}.sv-table thead th{background:#0c0c0c;color:#fff;font-weight:600;padding:14px 18px;text-align:left;font-size:13px}.sv-table tbody tr{border-bottom:1px solid #f0f0f0}.sv-table tbody tr:last-child{border-bottom:none}.sv-table tbody tr:nth-child(even){background:#fafafa}.sv-table td{padding:12px 18px;color:#333}.sv-table td:first-child{font-weight:500;color:#1a1a1a;width:52%}.sv-highlight{color:#dc2626;font-weight:600}.sv-note{background:#fff8e6;border:1px solid #efd9a0;border-radius:12px;padding:18px 20px;font-size:13.5px;line-height:1.65;color:#5c4a1c;margin-bottom:28px}.sv-note strong{color:#3d3210}.sv-seo{font-size:14px;color:#555;line-height:1.8;margin-top:32px;padding-top:24px;border-top:1px solid #eee}.sv-seo h4{font-size:15px;font-weight:600;color:#1a1a1a;margin:20px 0 8px}.sv-faq{margin-top:0;padding-top:0;border-top:none}.sv-faq-item{background:#f8f8f8;border-radius:12px;padding:20px;margin-bottom:12px}.sv-faq-item summary{font-size:14px;font-weight:600;color:#1a1a1a;cursor:pointer;list-style:none;display:flex;align-items:center;gap:10px}.sv-faq-item summary::-webkit-details-marker{display:none}.sv-faq-item summary::before{content:'';display:inline-block;width:8px;height:8px;border-right:2px solid #dc2626;border-bottom:2px solid #dc2626;transform:rotate(-45deg);transition:transform 0.2s;flex-shrink:0}.sv-faq-item[open] summary::before{transform:rotate(45deg)}.sv-faq-item p{font-size:13px;color:#555;margin:12px 0 0 18px;line-height:1.7}\u003c\/style\u003e\n\u003cdiv class=\"sv-product\"\u003e\n\n\u003cdiv class=\"sv-dach\"\u003e\n\n\u003cspan class=\"sv-dach-flags\"\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"7\" fill=\"#000000\"\u003e\u003c\/rect\u003e\u003crect y=\"7\" width=\"30\" height=\"7\" fill=\"#DD0000\"\u003e\u003c\/rect\u003e\u003crect y=\"14\" width=\"30\" height=\"7\" fill=\"#FFCE00\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"21\" fill=\"#ED2939\"\u003e\u003c\/rect\u003e\u003crect y=\"7\" width=\"30\" height=\"7\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003csvg viewbox=\"0 0 30 21\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003crect width=\"30\" height=\"21\" fill=\"#D52B1E\"\u003e\u003c\/rect\u003e\u003crect x=\"13\" y=\"4.5\" width=\"4\" height=\"12\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003crect x=\"9\" y=\"8.5\" width=\"12\" height=\"4\" fill=\"#FFFFFF\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003c\/span\u003e\n\u003cspan class=\"sv-dach-body\"\u003e\u003cspan class=\"sv-dach-head\"\u003e\u003cb\u003eDACH Version\u003c\/b\u003e\u003cspan class=\"sv-dach-tag\"\u003eGermany · Austria · Switzerland\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"sv-dach-sub\"\u003eControl and documentation in German, mains connection 230 V \/ 50 Hz according to Central European standard – can be used in all three countries.\u003c\/span\u003e\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stats\"\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e4.51 \u003cspan\u003ekW\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eHeating output at A7\/W35\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e4.9 \u003cspan\u003eCOP\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eCoefficient of Performance at A7\/W35\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e62 \u003cspan\u003e°C\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMax. flow temperature\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat\"\u003e\n\n\u003cdiv class=\"sv-stat-val\"\u003e40 \u003cspan\u003em\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-stat-label\"\u003eMax. pipe length\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-note\"\u003e\n\n\u003cstrong\u003ePlease note: Outdoor unit, not a complete system.\u003c\/strong\u003e The VWL 55\/8.2 AS is the split outdoor unit. For an operational system, an indoor unit – hydraulic station or uniTOWER – as well as the refrigerant lines and system control are added. We assemble the appropriate package upon request.\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eAdvantages at a glance\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-features\"\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e⚡\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eCOP 4.9 at A7\/W35\u003c\/h4\u003e\n\n\u003cp\u003e4.51 kW heating output with only 0.92 kW input. Even at -7 °C, the unit still delivers 4.89 kW with a COP of 3.0.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔧\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eSplit instead of monoblock\u003c\/h4\u003e\n\n\u003cp\u003eOnly refrigerant lines lead into the house, no water-carrying circuit outside. This eliminates the need for frost protection in the connecting line.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e📏\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eUp to 40 m pipe length\u003c\/h4\u003e\n\n\u003cp\u003eUp to 30 m height difference if the outdoor unit is at the top, 10 m if reversed. This provides a lot of freedom in placement.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔊\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eWhisper mode\u003c\/h4\u003e\n\n\u003cp\u003e57 dB(A) maximum at A7\/W35, in 60% whisper mode at A-7\/W35 only 47.6 dB(A).\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e❄️\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003eActive cooling\u003c\/h4\u003e\n\n\u003cp\u003eIntegrated active cooling operation: 5.31 kW at A35\/W18 with EER 4.2, in component cooling operation 5.22 kW at A35\/W7.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-feature\"\u003e\n\n\u003cdiv class=\"sv-feature-icon\"\u003e🔌\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4\u003e230 V – no heavy-duty current required\u003c\/h4\u003e\n\n\u003cp\u003eSingle-phase connection with a maximum of 12 A and 2.7 kW electrical power consumption.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003ePerformance \u0026amp; Efficiency according to EN 14511\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eOperating point\u003c\/th\u003e\n\n\u003cth\u003eOutput \/ Input \/ COP or EER\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W35\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003e4.51 kW \/ 0.92 kW \/ 4.9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA2\/W35\u003c\/td\u003e\n\n\u003ctd\u003e2.22 kW \/ 0.56 kW \/ 4.0\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA−7\/W35\u003c\/td\u003e\n\n\u003ctd\u003e4.89 kW \/ 1.63 kW \/ 3.0\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W45\u003c\/td\u003e\n\n\u003ctd\u003e4.13 kW \/ 1.15 kW \/ 3.6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eA7\/W55\u003c\/td\u003e\n\n\u003ctd\u003e5.36 kW \/ 1.91 kW \/ 2.8\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCooling A35\/W18\u003c\/td\u003e\n\n\u003ctd\u003e5.31 kW \/ 1.26 kW \/ EER 4.2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCooling A35\/W7\u003c\/td\u003e\n\n\u003ctd\u003e5.22 kW \/ 1.74 kW \/ EER 3.0\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eTechnical Data\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eParameter\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eType\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003eSplit outdoor unit (AS)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRefrigerant \/ pre-filled quantity \/ GWP\u003c\/td\u003e\n\n\u003ctd\u003eR32 \/ 1.3 kg \/ 675\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCO₂ equivalent\u003c\/td\u003e\n\n\u003ctd\u003e0.88 t\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eElectrical power consumption (max)\u003c\/td\u003e\n\n\u003ctd\u003e2.7 kW\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eVoltage supply \/ Current (max)\u003c\/td\u003e\n\n\u003ctd\u003e230 V (50 Hz) \/ 12 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\n\u003ctd\u003eIP14B\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power level at A7\/W35 (max)\u003c\/td\u003e\n\n\u003ctd\u003e57 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power level (ErP)\u003c\/td\u003e\n\n\u003ctd\u003e47.5 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSound power A-7\/W35 in 60% whisper mode\u003c\/td\u003e\n\n\u003ctd\u003e47.6 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eConnection suction gas \/ liquid line\u003c\/td\u003e\n\n\u003ctd\u003e1\/2″ \/ 1\/4″\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\n\u003ctd\u003e765 × 1,100 × 450 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eWeight ready for operation \/ gross\u003c\/td\u003e\n\n\u003ctd\u003e86 kg \/ 107 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-section\"\u003e\n\n\u003ch3 class=\"sv-section-title\"\u003eOperating limits\u003c\/h3\u003e\n\n\u003cdiv class=\"sv-table-wrap\"\u003e\u003ctable class=\"sv-table\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eParameter\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeating temperature\u003c\/td\u003e\n\n\u003ctd class=\"sv-highlight\"\u003e5 – 62 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\n\u003ctd\u003emax. 55 °C, with auxiliary heating 70 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDistance between indoor and outdoor unit\u003c\/td\u003e\n\n\u003ctd\u003emax. 40 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeight difference, outdoor unit above\u003c\/td\u003e\n\n\u003ctd\u003emax. 30 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eHeight difference, outdoor unit below\u003c\/td\u003e\n\n\u003ctd\u003emax. 10 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sv-seo sv-faq\"\u003e\n\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhat does the DACH version mean?\u003c\/summary\u003e\u003cp\u003eThe device, control, and documentation are designed for the German-speaking region: menu navigation and documentation in German, mains connection 230 V \/ 50 Hz. This means the heat pump can be used equally in Germany, Austria, and Switzerland. Funding and registration requirements differ by country – your local installer will clarify this.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eSplit or monoblock – which is better?\u003c\/summary\u003e\u003cp\u003eIn a split system, only refrigerant flows between the outdoor and indoor units, so nothing can freeze. However, it requires a refrigerant connection and thus a refrigeration certificate for commissioning. A monoblock like the aroTHERM plus is hydraulically simpler, but must be connected frost-proof.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhich refrigerant is used?\u003c\/summary\u003e\u003cp\u003eR32 with a GWP of 675 and 1.3 kg pre-fill, corresponding to 0.88 t CO₂ equivalent. If you prefer a natural refrigerant, the aroTHERM plus monoblock series offers devices with R290 and a GWP of 0.02.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eDoes the 5 kW size suit my house?\u003c\/summary\u003e\u003cp\u003eThe VWL 55\/8.2 AS delivers 4.89 kW at -7 °C and 4.51 kW at 7 °C, each at 35 °C flow. This is suitable for single-family homes with approximately 5 to 6 kW heating load. The exact dimensioning requires a heating load calculation according to EN 12831.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eHow far away can the outdoor unit be placed?\u003c\/summary\u003e\u003cp\u003eUp to 40 m pipe length between the indoor and outdoor units. If the outdoor unit is higher, a height difference of up to 30 m is allowed; if it is lower, up to 10 m.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"sv-faq-item\"\u003e\u003csummary\u003eWhere can I buy the Vaillant heat pump?\u003c\/summary\u003e\u003cp\u003eAt SOLARVIC on solarvic.at – as a specialist dealer and installer, we deliver throughout Austria and provide advice on sizing. Shipping within Austria is free for orders over €5,000.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Was bedeutet die DACH Version?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Regelung und Dokumentation in Deutsch, Netzanschluss 230 V \/ 50 Hz - einsetzbar in Deutschland, Oesterreich und der Schweiz.\"}},{\"@type\":\"Question\",\"name\":\"Split oder Monoblock?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Beim Split laeuft nur Kaeltemittel nach draussen, nichts kann einfrieren. Dafuer braucht die Inbetriebnahme einen Kaelteschein.\"}},{\"@type\":\"Question\",\"name\":\"Welches Kaeltemittel wird verwendet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"R32 mit GWP 675, 1,3 kg vorgefuellt, entsprechend 0,88 t CO2-Aequivalent.\"}},{\"@type\":\"Question\",\"name\":\"Wie weit darf die Aussenheit entfernt stehen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Bis 40 m Leitungslaenge, bis 30 m Hoehenunterschied wenn die Aussenheit oben steht, bis 10 m wenn sie tiefer steht.\"}}]}\u003c\/script\u003e","brand":"VAILLANT","offers":[{"title":"Default Title","offer_id":56294431261003,"sku":"VA0010039757","price":5171.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/HP23-aroTHERM_20Split_20plus-Rside_2001.png?v=1788089510"},{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-hp-1ph-9-kw-aussengerat-wh-udz09ke5-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic L\/W Aquarea K HP Heat Pump, 1ph, 9 kW, Outdoor Unit - WH-UDZ09KE5","description":"\u003cp\u003eSplit-type air-to-water heat pump\u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir-to-water heat pump for heating, domestic hot water preparation, and cooling (cooling mode can be activated via settings), consisting of an outdoor unit and an indoor unit (combi-hydro module), which is a combination of a hydro module and a hot water tank. \u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit\u003cbr\u003e\nOutdoor unit for split-type air-to-water heat pump, 230 V, R32\u003cbr\u003e\nHousing made of galvanized and baked enamel sheet steel RAL 7016, for outdoor installation, removable housing lid for easy access to internal components. Base plate with mounting tabs and condensate drain. \u003cbr\u003e\nAxial fan with continuously adjustable DC motor and a sound and flow-optimized plastic impeller. \u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Air-cooled heat exchanger made of copper pipes with corrugated aluminum fins with coating. Twin rotary compressor, sound-insulated and vibration-damped mounted, and equipped with a pressure-side silencer. Electronic expansion valve, 4-way reversing valve, filter dryer, and shut-off valves with test connection. Factory tested for pressure resistance and leak tightness and pre-filled with refrigerant. Long line lengths up to 40 m and height differences up to 30 m between indoor and outdoor unit are permissible. \u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nStainless steel plate heat exchanger. Circulation pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of water flow rate depending on the specified temperature spread, integrated dirty water magnetic filter for the water circuit, electric heating element with thermal overcurrent trip. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi-hydro module is 60 °C and is reached even down to -10 °C outdoor temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating mode possible down to -20 °C, cooling mode up to +10 °C outdoor temperature. The maximum water temperature in the domestic hot water tank is 65 °C. \u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet, and hot water outlet of the hot water tank are routed upwards from the unit in a row next to each other. \u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating capacity adjustment of the compressor by INVERTER+ control electronics. Temperature sensors for outdoor temperature, compressor, hot gas, and suction line temperature, as well as evaporator temperature. Higher efficiency, as the compressor starts in partial load operation and the compressor frequency is increased if required, circuit reversal for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting behavior through bypass defrosting. Communication modules for optimal data exchange with the hydro module. Electronic manometer provides value in electronic form for transmission via WLAN\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\n• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with the Aquarea Smart Cloud (CZ-TAW1B)Electrical equipment:\u003cbr\u003e\n• Auxiliary electric heater 3kW\u003cbr\u003e\n• Thermal overload protection for auxiliary electric heater\u003cbr\u003e\n• RCD\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Additional functions: weekly timer, holiday programs, secondary pump control, bivalence control, selectable temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (quiet mode priority \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrost function, during defrost operation the heat pump can switch to hot water mode. \u003cbr\u003e\nSeparate heating or domestic hot water control with a clear control panel (controller) with backlit 3.5-inch display and keypad with touch keys. Easy-to-understand symbols and clear text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow, and return temperature. Weekly timer for time-dependent on\/off switching and operating mode preset. Programmable timer for thermal disinfection. Demand-dependent control of the auxiliary electric heater. \u003cbr\u003e\nConformity with EU directives \u003cbr\u003e\nThe device complies with the relevant EU directives and standards. \u003cbr\u003e\n\u003cbr\u003e\nTechnical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 9.00 kW\/ 4.55\u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 8.90 kW\/ 2.93\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 7.00 kW\/ 3.40\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 6.30 kW \/ 2.18\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 6.25 kW \/ 2.84\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 5.90 kW \/ 1.93\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 8.20 kW \/ 2.72\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 9.00 kW \/ 4.18\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), moderate climate, W35 \/ W55 175% \/133% SCOP 4.44 \/ 3.41\u003cbr\u003e\nEnergy efficiency class heating, moderate climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 227% \/ 160% SCOP 5.75 \/ 4.07\u003cbr\u003e\nEnergy efficiency class heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 164% \/ 116% SCOP 4.18 \/ 2.98\u003cbr\u003e\nEnergy efficiency class heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A+\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UDZ09KE5\u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 56 \u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62\/\u003cbr\u003e\nDimensions \/ Net weight H x W x D mm \/ kg 795 x 875 x 380 \/ 55\u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 1.3 \/ 0.878\u003cbr\u003e\nPipe diameter Liquid line \/ Suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (5\/8) \u003cbr\u003e\nPipe length (min. – max.) at -25°C m 3– 40\u003cbr\u003e\nHeight difference IDU\/ODU (max.) m 30\u003cbr\u003e\nOperating range outdoor temperature °C –25 \/ +35\u003cbr\u003e\nWater outlet temp. Heating \/ Cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294496043339,"sku":"PAWHUDZ09KE5","price":3326.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/30aef98e9875abfde81ded3319d97278.webp?v=1768552834"},{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-hp-1ph-5-kw-aussengerat-wh-udz05ke5-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic A\/W Heat Pump Aquarea K HP, 1ph, 5 kW, Outdoor Unit – WH-UDZ05KE5","description":"\u003cp\u003eAir-to-water heat pump in split design\u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir-to-water heat pump for heating, domestic hot water preparation, and cooling (cooling mode can be activated via settings), consisting of an outdoor unit and an indoor unit (combi hydro module), which is a combination of a hydro module and a hot water tank.\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit\u003cbr\u003e\nOutdoor unit for air-to-water heat pump in split design, 230 V, R32\u003cbr\u003e\nHousing made of galvanized and stove-enamelled sheet steel RAL 7016, for outdoor installation, removable housing cover for easy access to internal components. Base plate with mounting tabs and condensate opening.\u003cbr\u003e\nAxial fan with continuously variable DC motor and a sound- and flow-optimized plastic impeller.\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Air-cooled heat exchanger made of copper pipes with corrugated aluminum fins with coating. Double-rotary compressor, sound-insulated and vibration-damped mounted, and equipped with a pressure-side silencer. Electronic expansion valve, 4-way reverse cycle valve, filter drier, and shut-off valves with test port. Factory tested for pressure resistance and leak tightness and pre-filled with refrigerant. Long line lengths up to 40 m and height differences up to 30 m between indoor and outdoor unit are permissible.\u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nPlate heat exchanger made of stainless steel. Circulating pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of water flow in relation to the specified temperature spread, integrated dirty water magnetic filter for the water circuit, electric heating rod with thermal overcurrent trip. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi hydro module is 60 °C and is reached even down to -10 °C ambient temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating operation up to -20 °C, cooling operation up to +10 °C ambient temperature possible. The maximum water temperature in the domestic hot water tank is 65 °C.\u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet and hot water outlet of the hot water tank are routed in a row side-by-side upwards out of the unit.\u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating compressor output adjustment via INVERTER+ control electronics. Temperature sensors for outdoor temperature, compressor, hot gas and suction line temperature, and evaporator temperature. Higher efficiency, as the compressor starts in partial load operation and the compressor frequency is increased if necessary, reverse cycle for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting behavior through bypass defrosting. Communication modules for optimal data exchange with the hydro module. Electronic manometer provides value in electronic form for transmission via WLAN.\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\u003c!--nl\"\/\u003e• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with the Aquarea Smart Cloud (CZ-TAW1B) Electrical equipment:\u003cbr\u003e\n• Electric auxiliary heater 3kW\u003cbr\u003e\n• Thermal overload protection for electric auxiliary heater\u003cbr\u003e\n• RCD\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Other functions: weekly timer, holiday programs, secondary pump control, bivalence control, optional temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (priority quiet mode \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrost function, during defrost operation the heat pump can switch to hot water mode.\u003cbr\u003e\nSeparate heating or domestic hot water control with a clear control panel (controller) with a backlit 3.5-inch display and keypad with touch buttons. Easy-to-understand symbols and plain text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Weekly timer for time-dependent on\/off switching and operating mode pre-selection. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.\u003cbr\u003e\nConformity with EU directives\u003cbr\u003e\nThe device complies with the relevant EU directives and standards.\u003cbr\u003e\n\u003cbr\u003e\nTechnical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 5.00 kW\/ 5.10\u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 5.00 kW\/ 3.03\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 5.00 kW\/ 3.57\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 5.00 kW \/ 2.29\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 5.00 kW \/ 2.79\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 5.00 kW \/ 1.89\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 5.00 kW \/ 3.05\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 5.00 kW \/ 4.90\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), average climate, W35 \/ W55 202 % \/142 % SCOP 5.12 \/ 3.63\u003cbr\u003e\nEnergy efficiency class heating, average climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 237% \/ 165% SCOP 6.00 \/ 4.20\u003cbr\u003e\u003c!--nl'\u003eEnergy efficiency class heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 160 % \/ 115 % SCOP 4.08 \/ 2.95\u003cbr\u003e\nEnergy efficiency class heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A+\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UDZ05KE5\u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 55\u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62\/\u003cbr\u003e\nDimensions \/ Net weight H x W x D mm \/ kg 795 x 875 x 380 \/ 55\u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 1.3 \/ 0.878\u003cbr\u003e\nLine diameter Liquid line \/ Suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (5\/8)\u003cbr\u003e\nLine length (min. – max.) at -25°C m 3– 40\u003cbr\u003e\nHeight difference IG\/AG (max.) m 30\u003cbr\u003e\nOperating range outdoor temperature °C –25 \/ +35\u003cbr\u003e\nWater outlet temp. Heating \/ Cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294497059147,"sku":"PAWHUDZ05KE5","price":2504.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/5120b3683733c532730ce60878bed9c4.webp?v=1768552835"},{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-hp-1ph-3-kw-aussengerat-wh-udz03ke5-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic A2W Heat Pump Aquarea K HP, 1ph, 3 kW, Outdoor Unit – WH-UDZ03KE5","description":"\u003cp\u003eAir-to-water heat pump in split design\u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir-to-water heat pump for heating, domestic hot water preparation and cooling (cooling mode can be activated via settings), consisting of an outdoor unit and an indoor unit (combi hydro module), which is a combination of a hydro module and a hot water tank. \u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit\u003cbr\u003e\nOutdoor unit for air-to-water heat pump in split design, 230 V, R32\u003cbr\u003e\nHousing made of galvanized steel sheet with baked enamel finish RAL 7016, for outdoor installation, removable housing cover for easy access to internal components. Base plate with mounting tabs and condensate opening.\u003cbr\u003e\nAxial fan with continuously variable DC motor and a plastic impeller optimized for sound and flow.\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Air-cooled heat exchanger made of copper tubes with corrugated aluminum fins with coating. Twin rotary compressor, sound-insulated and vibration-dampened mounting, and equipped with a pressure-side muffler. Electronic expansion valve, 4-way reversing valve, filter drier, and shut-off valves with test port. Factory-tested for pressure resistance and leak tightness and pre-filled with refrigerant. Long pipe lengths up to 40 m and height differences up to 30 m between indoor and outdoor units are permissible.\u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nStainless steel plate heat exchanger. Circulation pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of water flow rate depending on the specified temperature spread, integrated magnetic dirt filter for the water circuit, electric heating element with thermal overcurrent release. Safety and bleed valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi hydro module is 60 °C and is achieved even at -10 °C ambient temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating mode possible down to -20 °C, cooling mode up to +10 °C ambient temperature. The maximum water temperature in the domestic hot water tank is 65 °C.\u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet and hot water outlet of the hot water tank are routed out of the unit upwards in a row next to each other.\u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating power adjustment of the compressor by INVERTER+ control electronics. Temperature sensors for outdoor temperature, compressor, hot gas and suction line temperature, and evaporator temperature. Higher efficiency because the compressor starts in partial load operation and the compressor frequency is increased as needed, circuit reversal for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting behavior through bypass defrosting. Communication modules for optimal data exchange with the hydro module. Electronic manometer provides value in electronic form for transmission via WLAN\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\n• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with Aquarea Smart Cloud (CZ-TAW1B)Electrical equipment:\u003cbr\u003e\n• Electric auxiliary heater 3kW\u003cbr\u003e\u003c!--nl\"\u003e• Thermal overload protection for electric auxiliary heater\u003cbr\u003e\n• Residual current device\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Other functions: weekly timer, holiday and public holiday programs, secondary pump control, bivalence control, optional control via outdoor temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (priority quiet mode \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrost function, during defrost operation the heat pump can switch to hot water mode.\u003cbr\u003e\nSeparate heating and domestic hot water control with a clear control panel (controller) with a backlit 3.5-inch display and keypad with touch buttons. Easy-to-understand symbols and plain text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-dependent adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Weekly timer for time-dependent on\/off switching and operating mode setting. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.\u003cbr\u003e\nConformity with EU directives \u003cbr\u003e\nThe device complies with the relevant EU directives and standards\u003cbr\u003e\n\u003cbr\u003e\n.Technical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 3.20 kW\/ 5.33\u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 3.20 kW\/ 2.81\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 3.20 kW\/ 3.64\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 3.20 kW \/ 2.19\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 3.30 kW \/ 2.80\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 3.20 kW \/ 1.79\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 3.20 kW \/ 3.52\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 3.20 kW \/ 4.71\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), average climate, W35 \/ W55 200% \/136% SCOP 5.07 \/ 3.47\u003cbr\u003e\nEnergy efficiency class heating, average climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 245% \/ 165% SCOP 6.20 \/ 4.20\u003cbr\u003e\nEnergy efficiency class heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 157% \/ 110% SCOP 4.00 \/ 2.83\u003cbr\u003e\nEnergy efficiency class heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A+\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UDZ03KE5\u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 55 \u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62\/ \u003cbr\u003e\nDimensions \/ Net weight H x W x D mm \/ kg 622 x 824 x 335 \/ 37 \u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 0.9 \/ 0.608\u003cbr\u003e\nPipe diameter Liquid line \/ Suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (5\/8) \u003cbr\u003e\nPipe length (min. – max.) at -25°C m 3– 25\u003cbr\u003e\nHeight difference IDU\/ODU (max.) m 20\u003cbr\u003e\nOperating range Outdoor temperature °C –25 \/ +35\u003cbr\u003e\nWater outlet temp. Heating \/ Cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294498009419,"sku":"PAWHUDZ03KE5","price":2423.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/15472193601867-1_fdded7dd-641d-4528-83ef-989a27dc2260.jpg?v=1787474926"},{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-t-cap-3ph-12-kw-aussengerat-wh-uxz12ke8-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic A2W Heat Pump Aquarea K T-CAP, 3ph, 12 kW, Outdoor Unit – WH-UXZ12KE8","description":"\u003cp\u003eAir\/water heat pump in split design with impressed current anode \u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir\/water heat pump for heating, domestic hot water preparation and cooling (cooling mode can be activated via setting), consisting of an outdoor unit and an indoor unit (combi hydromodule), which is a combination of a hydromodule and a hot water tank.\u003cbr\u003e\n\u003cbr\u003e\nIndoor unit\u003cbr\u003e\nParticularly compact housing made of galvanized and stove-enamelled sheet steel, color: white, with an almost square footprint (602 x 599 mm) and low height (1642 mm). Front can be completely removed for full access to the unit components. Unit installation on the floor, leveling using height-adjustable feet. Separate sheet steel control box with its own hinged door for electrical connections located inside the housing on the front. Control unit accessible without opening the housing.\u003cbr\u003e\nAll sensor readings can be retrieved via the control unit, 2 x CN-CNT connections MODBUS and Cloud Adapter can be connected, energy and heat meters can be connected via MODBUS. Hot water tank made of stainless steel (EN material no. 1.4521), capacity 185 l, including stainless steel water heat exchanger, including impressed current anode and tank temperature sensor, insulation with U-Vacua thermal insulation and polystyrene, design pressure 10 bar\u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nPlate heat exchanger made of stainless steel. Circulation pump as a Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of the water flow rate depending on the specified temperature spread, integrated dirty water magnetic filter for the water circuit, electric heating element with thermal overcurrent release. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi hydromodule is 60 °C and is reached even down to -10 °C outside temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating mode up to -20 °C, cooling mode up to +10 °C outside temperature possible. The maximum water temperature in the domestic hot water tank is 65 °C.\u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet and hot water outlet of the hot water tank are routed in a row next to each other upwards out of the unit.\u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating power adjustment of the compressor by INVERTER+ control electronics. Temperature sensors for outside temperature, compressor, hot gas and suction line temperature as well as evaporator temperature. Higher efficiency, as the compressor starts in partial load operation and the compressor frequency is increased if required, circuit reversal for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting behavior through bypass defrosting. Communication modules for optimal data exchange with the hydromodule. Electronic manometer provides value in electronic form for transmission via WLAN\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\n• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with the Aquarea Smart Cloud (CZ-TAW1B)\u003cbr\u003e\n\u003cbr\u003e\nElectrical equipment:\u003cbr\u003e\n• Electric auxiliary heater 9kW\u003cbr\u003e\n• Thermal overload protection for electric auxiliary heater\u003cbr\u003e\n• RCD\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Further functions: weekly timer, holiday programs, secondary pump control, bivalence control, optional control via outdoor temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (priority quiet mode \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrosting function, during defrosting operation the heat pump can switch to hot water mode.\u003cbr\u003e\nSeparate heating or domestic hot water control with a clear control panel (controller) with backlit 3.5-inch display and keypad with touch keys. Easy-to-understand symbols and plain text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Weekly timer for time-dependent on\/off switching and operating mode pre-setting. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.\u003cbr\u003e\n\u003cbr\u003e\nConformity with EU directives \u003cbr\u003e\nThe device complies with the relevant EU directives and standards.\u003cbr\u003e\n\u003cbr\u003e\nTechnical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 12.10 kW \/ 4.84 \u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 12.10 kW \/ 3.04\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 12.00 kW \/ 3.44\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 12.00 kW \/ 2.29\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 12.00 kW \/ 2.72\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 12.00 kW \/ 2.29\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 10.70 kW \/ 2.68\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 10.70 kW \/ 3.92\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), moderate climate, W35 \/ W55 % 180 \/ 135 SCOP 4.58 \/ 3.46\u003cbr\u003e\nEnergy efficiency class Heating, moderate climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 % 256 \/ 171 SCOP 6.47 \/ 4.34\u003cbr\u003e\nEnergy efficiency class Heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 % 169 \/ 127 SCOP 4.31 \/ 3.26\u003cbr\u003e\nEnergy efficiency class Heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A++\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UXZ12KE8 \u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 65\u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62 \/\u003cbr\u003e\nDimensions \/ Net weight H x W x D mm \/ kg 1340 x 900 x 320 \/ 90\u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 1.6 \/ 1.080\u003cbr\u003e\nPipe diameter Liquid line \/ Suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (1\/2)\u003cbr\u003e\nPipe length (min. – max.) m 3–30\u003cbr\u003e\nHeight difference ID\/OD (max.) m 20\u003cbr\u003e\nOperating range outdoor temperature °C –28 \/+35\u003cbr\u003e\nWater outlet temp. Heating \/ Cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56294960365899,"sku":"PAWHUXZ12KE8","price":6313.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/fcb2fe5fc26f601a9e6fc947810aabc6.webp?v=1768552437"},{"product_id":"ochsner-ochsner-luft-wasser-warmepumpe-8-kw-vvs-falcon-212-ral-7016-aussengerat-9120392-verkaufseinheit-1-stuck","title":"OCHSNER OCHSNER Air\/Water Heat Pump 8 kW VVS FALCON 212 RAL 7016, Outdoor Unit – 9120392","description":"\u003cp\u003eStandard accessories for- Appliance type: AIR FALCON 212 Technical data- Dimensions (HxWxD): 998x940x384 mm- Weight (without packaging): 73 kg- Evaporator type: Finned tube- Evaporator material (WQA): Copper\/Aluminum- Number of fans: 1 pc.\u003c\/p\u003e","brand":"OCHSNER","offers":[{"title":"Default Title","offer_id":56295046086987,"sku":"OCHS9120392","price":3993.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/41bd29ed3f8f4579a671d9cd89b49e73.webp?v=1768552613"},{"product_id":"ochsner-ochsner-luft-wasser-warmepumpe-8-kw-air-falcon-212-c11a-m1-5-innengerat-287400v0001-verkaufseinheit-1-stuck","title":"OCHSNER OCHSNER Air\/Water Heat Pump 8 kW AIR FALCON 212 C11A M1-5, Indoor Unit – 287400V0001","description":"\u003cp\u003eCompact indoor unit for combination with the outdoor unit AIR FALCON 212 C11A. The wall-mounted hydrobox combines essential hydraulic components and control technology for efficient and space-saving operation. Pre-assembled hydraulic and control unit, Wall-mounted, space-saving design. Suitable for heating and optional cooling. Compatible with OCHSNER AIR FALCON 212 outdoor unit. Ideal for energy-efficient single and two-family homes.\u003c\/p\u003e","brand":"OCHSNER","offers":[{"title":"Default Title","offer_id":56295046971723,"sku":"OCHS287400V0001","price":7416.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/71106a12c8b8d393a4866d179bb6c130.webp?v=1768552614"},{"product_id":"ochsner-ochsner-luft-wasser-warmepumpe-8-kw-air-falcon-212-c11a-t200-innengerat-920917-verkaufseinheit-1-stuck","title":"OCHSNER OCHSNER Air\/Water Heat Pump 8 kW AIR FALCON 212 C11A T200, Indoor Unit – 920917","description":"\u003cp\u003eSuitable for single-family and two-family homes, underfloor heating, heating or heating\/cooling, max. flow temperature 60°C, OTS controller, SG Ready.\u003c\/p\u003e","brand":"OCHSNER","offers":[{"title":"Default Title","offer_id":56295047856459,"sku":"OCHS920917","price":10323.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/8754a68890a70777404e25590bb09e29.webp?v=1768552614"},{"product_id":"ochsner-ochsner-luft-wasser-warmepumpe-22-kw-air-hawk-726-c12a-innengerat-komp-it-160-verkaufseinheit-1-stuck","title":"OCHSNER OCHSNER Air\/Water Heat Pump 22 kW AIR HAWK 726 C12A, Indoor Unit – KOMP-IT-160","description":"\u003cp\u003eOchsner AIR HAWK 726 C12A Air\/Water Heat Pump with 22 kW heating capacity, split design, indoor unit KOMP-IT-160 for heating and cooling systems.\u003c\/p\u003e","brand":"OCHSNER","offers":[{"title":"Default Title","offer_id":56295499792715,"sku":"OCHS287320V0000","price":18761.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/no_photo_a1a953ad-9b7e-4248-9858-a69bc25dae68.png?v=1786632416"},{"product_id":"ochsner-ochsner-luft-wasser-warmepumpe-22-kw-vhs-hawk-726-ral-9017-aussengerat-komp-at-161-verkaufseinheit-1-stuck","title":"OCHSNER OCHSNER Air\/Water Heat Pump 22 kW VHS HAWK 726 RAL 9017, Outdoor Unit – KOMP-AT-161","description":"\u003cp\u003eOchsner VHS HAWK 726 Air\/Water Heat Pump with 22 kW heating capacity, split design as outdoor unit, RAL 9017 color, for heating.\u003c\/p\u003e","brand":"OCHSNER","offers":[{"title":"Default Title","offer_id":56295500906827,"sku":"OCHS290838V0009","price":10101.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/no_photo_bcb7aa9e-79e4-479b-9e57-bb9db76c044a.png?v=1786632416"},{"product_id":"panasonic-panasonic-l-w-warmepumpe-aquarea-k-t-cap-3ph-16-kw-aussengerat-wh-uxz16ke8-verkaufseinheit-1-stuck","title":"PANASONIC Panasonic A\/W heat pump Aquarea K T-CAP, 3ph, 16 kW, outdoor unit – WH-UXZ16KE8","description":"\u003cp\u003eAir\/water heat pump in split design with impressed current anode \u003cbr\u003e\n\u003cbr\u003e\nDescription\u003cbr\u003e\nAir\/water heat pump for heating, domestic hot water preparation and cooling (cooling mode activatable by setting), consisting of an outdoor unit and an indoor unit (combi hydro module), which is a combination of a hydro module and a hot water tank.\u003cbr\u003e\n\u003cbr\u003e\nIndoor unit\u003cbr\u003e\nParticularly compact housing made of galvanized and stove-enamelled steel sheet, color: white, with an almost square footprint (602 x 599 mm) and low height (1642 mm). Front fully removable for full access to the unit components. Unit installation on the floor, leveling by means of height-adjustable feet. Separate control box made of steel sheet with its own hinged door for the electrical connections located inside the housing on the front. Control unit accessible without opening the housing.\u003cbr\u003e\nAll sensor readings can be accessed via the control unit, 2 x CN-CNT connections MODBUS and Cloud Adapter can be connected, energy and heat meters can be connected via MODBUS. Stainless steel hot water tank (EN material no. 1.4521), capacity 185 l, including stainless steel water heat exchanger, including impressed current anode and tank temperature sensor, insulation with U-Vacua thermal insulation and polystyrene, design pressure 10 bar\u003cbr\u003e\n\u003cbr\u003e\nHydraulic circuit\u003cbr\u003e\nStainless steel plate heat exchanger. Circulating pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of water flow depending on the specified temperature spread, integrated dirty water magnetic filter for the water circuit, electric heating element with thermal overcurrent release. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. 3-way valve for switching between hot water mode and heating or cooling mode. The maximum water outlet temperature at the combi hydro module is 60 °C and is reached even down to -10 °C outdoor temperature. The minimum water outlet temperature in cooling mode is 5 °C. Heating mode possible down to -20 °C, cooling mode up to +10 °C outdoor temperature. The maximum water temperature in the domestic hot water tank is 65 °C.\u003cbr\u003e\n\u003cbr\u003e\nConnections\u003cbr\u003e\nConnections for refrigerant lines as well as for flow and return (heating\/cooling), cold water inlet and hot water outlet of the hot water tank are routed upwards from the unit in a single row.\u003cbr\u003e\n\u003cbr\u003e\nControl\u003cbr\u003e\nModulating power adaptation of the compressor by INVERTER+ control electronics. Temperature sensors for outdoor temperature, compressor, hot gas and suction line temperature as well as evaporator temperature. Higher efficiency because the compressor starts in partial load operation and the compressor frequency is increased as needed, circuit reversal for rapid and efficient defrosting of the outdoor unit heat exchanger. Improved defrosting performance through bypass defrosting. Communication modules for optimal data exchange with the hydro module. Electronic pressure gauge provides value in electronic form for transmission via WLAN\u003cbr\u003e\n\u003cbr\u003e\nOptional board (CZ-NS5P) for additional functions:\u003cbr\u003e\n• Control input for external on\/off switching\u003cbr\u003e\n• Control input for external room thermostat\u003cbr\u003e\n• Control output for 2-way valve (cooling mode)\u003cbr\u003e\n• Control output for 3-way valve (heating \/ domestic hot water)\u003cbr\u003e\n• Interface for communication with the Aquarea Smart Cloud (CZ-TAW1B)\u003cbr\u003e\n\u003cbr\u003e\nElectrical equipment:\u003cbr\u003e\n• 9kW electric auxiliary heater\u003cbr\u003e\n• Thermal overload protection for electric auxiliary heater\u003cbr\u003e\n• RCD\u003cbr\u003e\n• Control inputs and outputs\u003cbr\u003e\n\u003cbr\u003e\nSystem\u003cbr\u003e\nThe system is optimized for R32 refrigerant with low global warming potential. Functions include heating mode, cooling mode, screed drying, automatic mode, display of energy consumption and generation. Other functions: weekly timer, holiday programs, secondary pump control, bivalence control, optional control via outdoor temperature sensor or room temperature sensor\/thermostat, intelligent quiet mode (quiet mode priority \"performance\"), optional board for additional functions such as control and temperature regulation of a buffer tank, control of two heating circuits (including swimming pool heating), input for external shutdown of the outdoor unit, integration of a solar station, external fault messages, inputs for SG-Ready control. Integration into third-party BMS systems via optional interfaces. Optional Smart Cloud adapter for operation and remote maintenance via Panasonic Cloud applications. Simultaneous use of the BMS system and the Smart Cloud adapter. Self-diagnosis system with display of error codes, improved defrost function, during defrost operation the heat pump can switch to hot water mode.\u003cbr\u003e\nSeparate heating and domestic hot water control with a clear control panel (controller) with backlit 3.5-inch display and keypad with touch keys. Easy-to-understand symbols and plain text menu displays in 16 different user languages. Additional quick menu for the user. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adaptation of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Weekly timer for time-dependent on\/off switching and operating mode preselection. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.\u003cbr\u003e\n\u003cbr\u003e\nCompliance with EU directives \u003cbr\u003e\nThe device complies with the relevant EU directives and standards.\u003cbr\u003e\n\u003cbr\u003e\nTechnical data\u003cbr\u003e\nHeating capacity \/ COP (A7\/W35) 16.00 kW \/ 4.38 \u003cbr\u003e\nHeating capacity \/ COP (A7\/W55) 16.00 kW \/ 2.72\u003cbr\u003e\nHeating capacity \/ COP (A2\/W35) 16.00 kW \/ 3.10\u003cbr\u003e\nHeating capacity \/ COP (A2\/W55) 16.00 kW \/ 2.07\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W35) 16.00 kW \/ 2.39\u003cbr\u003e\nHeating capacity \/ COP (A–7\/W55) 16.00 kW \/ 1.71\u003cbr\u003e\nCooling capacity \/ EER (A35\/W7) 13.40 kW \/ 2.64\u003cbr\u003e\nCooling capacity \/ EER (A35\/W18) 13.40 kW \/ 2.64\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), medium climate, W35 \/ W55 % 176 \/ 129 SCOP 4.46 \/ 3.31\u003cbr\u003e\nEnergy efficiency class heating, medium climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), warmer climate, W35 \/ W55 % 232 \/ 160 SCOP 5.88 \/ 4.09\u003cbr\u003e\nEnergy efficiency class heating, warmer climate, scale: A+++ to D, W35 \/ W55 A+++ \/ A+++\u003cbr\u003e\nSeasonal space heating energy efficiency (ηs,h), colder climate, W35 \/ W55 % 150 \/ 125 SCOP 3.83 \/ 3.20\u003cbr\u003e\nEnergy efficiency class heating, colder climate, scale: A+++ to D, W35 \/ W55 A++ \/ A++\u003cbr\u003e\n\u003cbr\u003e\nOutdoor unit WH-UXZ12KE8 \u003cbr\u003e\nSound power level (partial load, ErP, A7\/W55) Heating dB(A) 65\u003cbr\u003e\nSound power level (full load, Er) Heating \/ Cooling dB(A) 62 \/\u003cbr\u003e\n Dimensions \/ Net weight H x W x D mm \/ kg 1340 x 900 x 320 \/ 103\u003cbr\u003e\nPre-filled refrigerant quantity (R32) \/ CO2 equivalent kg \/ t 1.83\/ 1.235\u003cbr\u003e\nPipe diameter liquid line \/ suction gas line mm (inch) 6.35 (1\/4) \/ 12.70 (1\/2)\u003cbr\u003e\nPipe length (min. – max.) m 3–30\u003cbr\u003e\nHeight difference IG\/AG (max.) m 20\u003cbr\u003e\nOperating range outdoor temperature °C –28 \/+35\u003cbr\u003e\nWater outlet temp. heating \/ cooling °C 20 – 60 (above -10°C ambient temp.) \/ 5 – 20\u003c\/p\u003e","brand":"PANASONIC","offers":[{"title":"Default Title","offer_id":56316665528651,"sku":"PAWHUXZ16KE8","price":7327.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/1489f55bd7790732df10bc2608eaede6.webp?v=1768805852"}],"url":"https:\/\/solarvic.at\/en\/collections\/energie-waermepumpe-luft-wasser-split.oembed","provider":"SOLARVIC | Photovoltaik \u0026 Haustechnik","version":"1.0","type":"link"}