{"title":"Counting technology","description":null,"products":[{"product_id":"eltako-wechselstromzahler-mid-28065615-verkaufseinheit-1-stuck","title":"ELTAKO AC meter, MID – 28065615","description":"\u003cp\u003eMaximum current 65A, standby loss only 0.4 watts. Modular device for mounting on DIN-EN 60715 TH35 top-hat rail. 1 module = 18mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. This AC meter measures active energy based on the current flowing between the input and the output. The meter's own consumption of only a maximum of 0.4 watts of active power is not measured and not displayed. 1 external conductor with a current of up to 65A can be connected. The starting current is 40mA. If a load of more than 50% is expected, a ventilation distance of 1\/2 module must be maintained from adjacent devices. If necessary, use the DS12 spacer. Two N terminals for safe cross-wiring of multiple meters. The 7-segment LCD display can be read twice within two weeks even without a power supply. To do this, press the button. Below the display there is a button with which you can scroll through the menu according to the operating instructions. First, the backlight switches on. Then the total active energy, the active energy of the resettable memory, and the instantaneous values of active power, voltage, and current can be displayed. Power consumption is indicated by a bar flashing 1000 times per kWh on the display. Error message: In case of a connection error, the display backlight flashes.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56294370869579,"sku":"ELT28065615","price":81.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/117b0267065b661ba3333ab16a4deb3b.webp?v=1768552427"},{"product_id":"reltech-drehstromzahler-digital-max-100a-mit-modbus-mid-zertifizierung-009564727756-verkaufseinheit-1-stuck","title":"RELTECH Digital Three-Phase Energy Meter, max. 100A, with MODbus, MID certified – 009564727756","description":"\u003cp\u003eRELTECH Digital Three-Phase Meter with MODbus and MID Certification, max. 100A Rated Current, for Three-Phase Measurements with Digital Display and Interface.\u003c\/p\u003e","brand":"RELTECH","offers":[{"title":"Default Title","offer_id":56295129678155,"sku":"REL009564727756","price":164.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/a51e79b1db6be500e4ef3e5a0aad2bc4.webp?v=1768552545"},{"product_id":"reltech-wechselstromzahler-digital-max-45a-s0-ausgang-mid-zertifizierung-004001005500-verkaufseinheit-1-stuck","title":"RELTECH AC Meter digital, max. 45A, S0 interface, MID certified – 004001005500","description":"\u003cp\u003eRELTECH Digital AC meter with max. 45A load capacity, S0 output, and MID certification for calibrated AC measurement.\u003c\/p\u003e","brand":"RELTECH","offers":[{"title":"Default Title","offer_id":56295131414859,"sku":"REL004001005500","price":39.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/0dce71891617ff39ead3e583ae524b5c.webp?v=1768552545"},{"product_id":"reltech-drehstromzahler-digital-max-100a-s0-ausgang-mid-zertifizierung-009007700040-verkaufseinheit-1-stuck","title":"RELTECH Digital Three-Phase Meter, max. 100A, S0 Output, MID Certified – 009007700040","description":"\u003cp\u003eRELTECH Digital Three-Phase Meter with max. 100A load capacity, S0 output and MID certification for precise energy measurement in industrial applications.\u003c\/p\u003e","brand":"RELTECH","offers":[{"title":"Default Title","offer_id":56295134200139,"sku":"REL009007700040","price":103.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/44d9980366198d1d9d511d1f12c43d7e.webp?v=1768552546"},{"product_id":"eltako-drehstromzahler-mid-2019-28380015-verkaufseinheit-1-stuck","title":"ELTAKO Three-Phase Meter, MID 2019 – 28380015","description":"\u003cp\u003eMaximum current 3x80 A, standby loss only 0.5 watts per path. Modular device for mounting on DIN-EN 60715 TH35 top-hat rail. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. The direct-metering three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The meter's own consumption of only a maximum of 0.5 watts of active power per path is not measured or displayed. 1, 2 or 3 phase conductors with currents up to 80A can be connected. The starting current is 40mA. The N connection must be present. The 7-segment LC display can be read twice within two weeks even without a power supply. Power consumption is indicated by a bar flashing 100 times per kWh on the display. Also available as a 2-tariff meter as standard: By applying 230V to terminals E1\/E2, the meter switches to a second tariff. To the right of the display are the MODE and SELECT buttons, which are used to navigate the menu according to the operating instructions. First, the backlight switches on. Then, the total active energy per tariff, the active energy of the resettable memory RS1 or RS2, as well as the instantaneous values of power, voltage, and current per phase conductor can be displayed. Error message (false): If a phase conductor is missing or the current direction is incorrect, \"false\" and the corresponding phase conductor are displayed.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56295500644683,"sku":"ELT28380015","price":170.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/cdccb229785145e29ddcf7ef890d6248.webp?v=1768552635"},{"product_id":"eltako-drehstromzahler-28380615-verkaufseinheit-1-stuck","title":"ELTAKO Three-Phase Meter – 28380615","description":"\u003cp\u003eMaximum current 3x80A, standby loss only 0.5 watts per path. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. The direct-measuring three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The meter's own consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. Like all meters without MID conformity declaration in Europe, not approved for monetary electricity billing. 1, 2 or 3 live conductors with currents up to 80 A can be connected. The starting current is 40mA. The N-connection must be present. The 7-segment LC display can also be read twice within two weeks without a power supply. Power consumption is indicated by a bar flashing 100 times per kWh on the display. Also available as a 2-tariff meter as standard: Applying 230V to terminals E1\/E2 switches to a second tariff. To the right of the display are the MODE and SELECT buttons, which are used to navigate through the menu according to the operating instructions. First, the backlight switches on. Then the total active energy per tariff, the active energy of the resettable memory RS1 or RS2, and the instantaneous values for power, voltage, and current per live conductor can be displayed. Error message (false): If a live conductor is missing or the current direction is incorrect, \"false\" and the corresponding live conductor are shown on the display.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56295501594955,"sku":"ELT28380615","price":125.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/5312a4a507224e9d591cb71bec188cf6.webp?v=1768552636"},{"product_id":"eltako-wandler-drehstromzahler-mid-2019-28305015-verkaufseinheit-1-stuck","title":"ELTAKO Converter Three-Phase Meter, MID 2019 – 28305015","description":"\u003cp\u003eCurrent transformer three-phase meter with settable transformer ratio and MID. Maximum current 3x5A, standby loss only 0.5 Watt per path. Series installation device for mounting on DIN-EN 60715 TH35 mounting rail. 4 module units = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. This three-phase meter measures active energy based on the currents flowing through the current transformers. The self-consumption of only a maximum of 0.5 Watt active power per path is not measured and not displayed. 1, 2 or 3 current transformers with secondary currents up to 5A can be connected. The starting current is 10mA. The N-connection must be present. The 7-segment LC display can be read twice within two weeks even without power supply. The power consumption is indicated by a bar flashing 10 times per kWh in the display. To the right of the display are the MODE and SELECT buttons, which are used to navigate the menu according to the operating instructions. First, the backlight switches on. Afterwards, the total active energy, the active energy of the resettable memory as well as the instantaneous values of power, voltage and current per phase conductor can be displayed. In addition, the current transformer ratio can be set. Ex-factory, it is set to 5:5 and locked with a jumper across the terminals marked 'JUMPER'. The current transformer ratio is adjusted to the installed transformer by removing the jumper and re-setting it according to the operating instructions. Afterwards, it is locked again with the jumper. The following current transformer ratios can be set: 5:5, 50:5, 100:5, 150:5, 200:5, 250:5, 300:5, 400:5, 500:5, 600:5, 750:5, 1000:5, 1250:5 and 1500:5. Error message (false): In case of a missing phase conductor or wrong current direction, \"false\" and the corresponding phase conductor are displayed. Attention! Before working on the current transformers, disconnect the voltage paths of the meter.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56295502577995,"sku":"ELT28305015","price":220.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/7c54568e1a3c6893eb14a93c10f57d14.webp?v=1768552636"},{"product_id":"eltako-wechselstromzahler-32a-mid-2019-28032015-verkaufseinheit-1-stuck","title":"ELTAKO AC Meter 32A, MID 2019 – 28032015","description":"\u003cp\u003eMaximum current 32A, standby loss only 0.4 watts. Modular device for mounting on DIN-EN 60715 TH35 top-hat rail. 1 module = 18mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. This AC meter measures active energy based on the current flowing between the input and output. The self-consumption of a maximum of 0.4 watts of active power is not measured and not displayed. 1 external conductor with a current of up to 32A can be connected. The starting current is 2OmA. If an expected load of more than 50% is anticipated, a ventilation distance of 1\/2 module must be maintained from adjacent devices. If necessary, use the DS12 spacer. Two N-terminals for safe cross-wiring of multiple meters. The 7-segment LC display can be read twice within two weeks even without a power supply. To do this, press the button. Below the display there is a button with which you can navigate through the menu according to the operating instructions. First, the backlight switches on. Then the total active energy, the active energy of the resettable memory, as well as the instantaneous values of active power, voltage, and current can be displayed. Power consumption is indicated by a bar flashing 1000 times per kWh on the display. Error message: In case of a connection error, the display's backlight flashes.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56295671431499,"sku":"ELT28032015","price":76.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/4ee651e445d84d947757fd0e0102fd98.webp?v=1768552697"},{"product_id":"eltako-wechselstromzahler-28032615-verkaufseinheit-1-stuck","title":"ELTAKO AC meter - 28032615","description":"\u003cp\u003eMaximum current 32A, standby loss only 0.4 watts. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 1 module = 18mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. This AC meter measures active energy based on the current flowing between the input and output. The self-consumption of only max. 0.4 watts active power is not measured or displayed. Like all meters without MID conformity declaration in Europe, not approved for monetary electricity billing. Every 30 seconds, the display switches for 5 seconds from the accumulated active energy in kWh to the instantaneous consumption in watts. 1 external conductor with a current of up to 32A can be connected. If a load of more than 50% is expected, a ventilation clearance of 1\/2 module must be maintained from adjacent devices. If necessary, use the DS12 spacer. The starting current is 20mA. The display can only be read with power supply. However, consumption is non-volatilely stored and is immediately displayed again after a power failure. Two N-terminals for safe cross-wiring of multiple meters. The digital display has 7 digits. Up to 99999.99 kWh, two decimal places are displayed. From 100000.0 kWh, only one. Power consumption is indicated by a bar flashing 1000 times per kWh on the display. Error message: In case of a connection error, an LED on the display flashes.\u003c\/p\u003e","brand":"ELTAKO","offers":[{"title":"Default Title","offer_id":56295672512843,"sku":"ELT28032615","price":70.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/5075\/6427\/files\/d65ad23338c990724d0ddd520ebf05fa.webp?v=1768552698"}],"url":"https:\/\/solarvic.at\/en\/collections\/elektro-zaehltechnik.oembed","provider":"SOLARVIC | Photovoltaik \u0026 Haustechnik","version":"1.0","type":"link"}